Multiple hot-film sensor array calibration and skin friction measurement

被引:0
|
作者
O. Desgeorges
T. Lee
F. Kafyeke
机构
[1] Department of Mechanical Engineering,
[2] McGill University Montreal,undefined
[3] Quebec,undefined
[4] Canada H3A n2K6 e-mail: Timlee@mecheng.mcgill.ca,undefined
来源
Experiments in Fluids | 2002年 / 32卷
关键词
Circular Cylinder; Skin Friction; Sensor Array; Friction Measurement; Test Cylinder;
D O I
暂无
中图分类号
学科分类号
摘要
A method for the calibration of closely spaced multiple hot-film sensor (MHFS) arrays of nickel-on-polyimide-substrate type was presented in this paper. The hot-film sensors were calibrated individually and in situ against the values of the wall-shear stresses determined from boundary-layer velocity profiles (developed on the front portion of a circular cylinder) through a specially designed wall-mounted hot-wire probe. The accuracy and feasibility of the present method was examined through the subsequent measurements of the skin-friction distributions on a circular cylinder (including the removal and bonding of the calibrated MHFS from a 10-cm diameter calibration cylinder and onto the surface of a 8-cm diameter test cylinder) and comparison of their consistency with the published results. The present MHFS calibration method is important in the non-intrusive multipoint measurements of the mean skin friction along the surfaces of two-dimensional aerodynamic objects of interest.
引用
收藏
页码:37 / 43
页数:6
相关论文
共 50 条
  • [1] Multiple hot-film sensor array calibration and skin friction measurement
    Desgeorges, O
    Lee, T
    Kafyeke, F
    EXPERIMENTS IN FLUIDS, 2002, 32 (01) : 37 - 43
  • [2] Multiple hot-film sensors calibration and skin friction measurement
    Lee, J
    Lee, T
    Kafyeke, F
    Mokhatrian, F
    48TH ANNUAL CONFERENCE OF THE CANADIAN AERONAUTICS AND SPACE INSTITUTE, PROCEEDINGS: CANADIAN AERONAUTICS-STAYING COMPETITIVE IN GLOBAL MARKETS, 2001, : 495 - 503
  • [3] A Flexible Hot-Film Sensor Array for Underwater Shear Stress and Transition Measurement
    Sun, Baoyun
    Wang, Pengbin
    Luo, Jian
    Deng, Jinjun
    Guo, Shiqi
    Ma, Binghe
    SENSORS, 2018, 18 (10)
  • [4] CALIBRATION OF HOT FILMS FOR SKIN FRICTION MEASUREMENT
    BROWN, GL
    DAVEY, RF
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1971, 42 (11): : 1729 - &
  • [5] CALIBRATION OF HOT-WIRE AND HOT-FILM PROBES
    BARFIELD, BJ
    HENSON, WH
    TRANSACTIONS OF THE ASAE, 1971, 14 (06): : 1100 - &
  • [6] Calibration and signal interpretation for single and multiple hot-wire hot-film probes
    Lekakis, I
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1996, 7 (10) : 1313 - 1333
  • [7] APPLICATIONS OF NANO HOT-FILM SENSOR FOR MICRO/NANOSCALE THERMAL MEASUREMENT
    Takahashi, Koji
    Hirotani, Jun
    Nishiyama, Takashi
    Ikuta, Tatsuya
    Takamatsu, Hiroshi
    PROCEEDINGS OF THE ASME MICRO/NANOSCALE HEAT AND MASS TRANSFER INTERNATIONAL CONFERENCE, 2012, 2012, : 677 - 681
  • [8] HOT-FILM SENSORS CALIBRATION DRIFT IN WATER
    JIMENEZ, J
    MARTINEZVAL, R
    REBOLLO, M
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1981, 14 (05): : 569 - 572
  • [9] CALIBRATION OF CYLINDRICAL HOT-FILM VELOCITY SENSORS
    ANDREAS, EL
    JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 1979, 46 (01): : 15 - 20
  • [10] Toward calibration-free wall shear stress measurement using a dual hot-film sensor and Kelvin bridges
    Liu, Xuanhe
    Li, Zhuoyue
    Wu, Chuijie
    Gao, Nan
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2018, 29 (10)