An improved delta-star switching scheme for reactive power saving in three-phase induction motors

被引:1
|
作者
Raja P. [1 ]
Kumaresan N. [1 ]
Subbiah M. [2 ]
机构
[1] Department of Electrical and Electronics Engineering, National Institute of Technology, Tiruchirappalli, Tamil Nadu
[2] Department of Electrical and Electronics Engineering, Rajalakshmi Engineering College, Chennai
关键词
Delta-star switching; Induction motor; Power factor; Steady-state analysis;
D O I
10.1007/s11708-014-0324-8
中图分类号
学科分类号
摘要
It is proposed that a capacitor can be connected permanently across each phase winding of a three-phase induction motor along with the conventional delta-star switching, for further saving in VARh at reduced loads on the motor. The method of choosing a suitable value for the capacitor and the criteria to be adopted for calculating the power output at which the star to delta switching is to be made are also explained. The experimental results on a 3- phase, 4-pole, 415 V, 50 Hz, 3.3 kWinduction motor verify the advantages in adding the capacitor to the phase winding of the motor. Compared to using only a single delta connected stator winding or a delta-star switching, the advantages of the proposed addition of a capacitor, are also demonstrated through a case study conducted on a 400 V, 250 kW motor. Any further improvement in grid side power factor can be achieved by employing a static synchronous compensator (STATCOM) of reduced VAR rating. © Higher Education Press and Springer-Verlag Berlin Heidelberg 2014.
引用
收藏
页码:364 / 370
页数:6
相关论文
共 50 条
  • [1] Star-delta starting for three-phase motors
    不详
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1922, 66 : 517 - 517
  • [2] Reactive power compensation in squirrel cage rotor type of three-phase induction motors
    Tjahjono, G.
    Ray, F. G.
    Fahmi, I.
    Tamal, C. P.
    Modok, R. H.
    Setiawaty, T.
    INTERNATIONAL CONFERENCE ON INNOVATION IN ENGINEERING AND VOCATIONAL EDUCATION 2019 (ICIEVE 2019), PTS 1-4, 2020, 830
  • [3] A three stage stator switching scheme for MWH and MVARh saving in induction motors
    Karthigaivel, R.
    Kumaresan, N.
    Subbiah, M.
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 1103 - +
  • [4] Definetion of dynamic power indications in three-phase induction motors
    Kopylov, O.P.
    Elektrotekhnika, 1992, (03): : 6 - 8
  • [5] Improved techniques for rotor fault detection in three-phase induction motors
    Watson, JF
    Paterson, NC
    CONFERENCE RECORD OF THE 1998 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-3, 1998, : 271 - 277
  • [6] On-Line Fault Diagnostics in Operating Three-Phase Induction Motors by the Active and Reactive Power Media
    Drif, M'hamed
    Cardoso, A. J. Marques
    ICEM: 2008 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES, VOLS 1- 4, 2009, : 1337 - 1342
  • [7] USE OF INTEGRAL CYCLE SWITCHING FOR CONTROL OF THREE-PHASE INDUCTION MOTORS.
    Feth, N.
    Abdel-Salam, M.
    El-Sayed, E.M.
    Systems Science, 1986, 12 (1-2): : 123 - 143
  • [8] Analysis of Equivalent Inductance of Three-Phase Induction Motors in the Switching Frequency Range
    Srndovic, Milan
    Fiser, Rastko
    Grandi, Gabriele
    ELECTRONICS, 2019, 8 (02):
  • [9] The Rapid Soft Re-switching Technology of Three-Phase Induction Motors
    Cui, Xueshen
    Luo, Yingli
    Wu, Ling
    Yang, Yulei
    Zhou, Zhenhua
    Liu, Xiaofang
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 1053 - 1058
  • [10] A three-phase multilevel converter for high-power induction motors
    Schibli, NP
    Nguyen, T
    Rufer, AC
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 1998, 13 (05) : 978 - 986