Transvenous lead extraction using the TightRail mechanical rotating dilator sheath for Asian patients

被引:0
|
作者
Ji-Hoon Choi
Seung-Jung Park
Hye Ree Kim
Hee-Jin Kwon
Kyoung-Min Park
Young Keun On
June Soo Kim
Ju Youn Kim
Won Young Jung
机构
[1] Sungkyunkwan University School of Medicine,Division of Cardiology, Department of Medicine, Heart Vascular and Stroke Institute, Samsung Medical Center
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The need for transvenous lead extraction (TLE) is increasing worldwide including in Asia–Pacific regions. However, supporting evidence for TightRail, a relatively new rotating mechanical dilator sheath, is still lacking in Asian patients. The efficacy and safety of TLE using TightRail performed between March 2018 and June 2021 were evaluated in 86 consecutive patients with 131 leads. The mean lead age was 11.7 ± 7.3 (range, 1.0–41.4) years. Clinical and complete procedural success using TightRail were achieved in 93.0% and 89.5% of 86 patients, respectively, with 6 min of median fluoroscopic time and 9.3% of major complication rate: death (1.2%), cardiac tamponade (3.5%), severe tricuspid regurgitation (3.5%), and stroke (1.2%). However, in 46 patients with longest lead age ≤ 10 years, clinical/complete success and major cardiac complication rates turned out better as 97.8%, 95.7%, and 2.2%, respectively. Additionally, when patients were divided into 3 groups: the first 28, second 29, and the last 29 patients, there was a clear trend toward better efficacy and safety outcomes with more experience with TightRail (Ptrend < 0.05). Longest lead age > 10 years was closely associated with TLE-related major cardiac complication (P = 0.046) with 85.7% sensitivity, 57.0% specificity, 15.0% positive predictive value, and 97.8% negative predictive values. In conclusion, TLE using TightRail may be effectively and safely performed by experienced operators for Asian patients with the longest lead age ≤ 10 years. However, as TightRail is a potentially aggressive tool, special attention should be paid to patients with longer lead dwelling times (e.g., > 10 years).
引用
收藏
相关论文
共 50 条
  • [1] Transvenous lead extraction using the TightRail mechanical rotating dilator sheath for Asian patients
    Choi, Ji-Hoon
    Park, Seung-Jung
    Kim, Hye Ree
    Kwon, Hee-Jin
    Park, Kyoung-Min
    On, Young Keun
    Kim, June Soo
    Kim, Ju Youn
    Jung, Won Young
    SCIENTIFIC REPORTS, 2022, 11 (01)
  • [2] Initial experience with the TightRail™ Rotating Mechanical Dilator Sheath for transvenous lead extraction
    Aytemir, Kudret
    Yorgun, Hikmet
    Canpolat, Ugur
    Sahiner, M. Levent
    Kaya, Ergun Baris
    Evranos, Banu
    Ozer, Necla
    EUROPACE, 2016, 18 (07): : 1043 - 1048
  • [3] Outcomes of transvenous lead extraction using the TightRail™ mechanical rotating dilator sheath and excimer laser sheath
    Misra, Satish
    Swayampakala, Kamala
    Coons, Patricia
    Cerbie, Claire
    Guifarro, Angello
    Lesiczka, Magdalena
    Holshouser, John W.
    Madjarov, Jeko
    Love, Charles
    Mehta, Rohit
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (07) : 1969 - 1978
  • [4] Initial experience with the Tightrail rotating mechanical dilator sheath for transvenous lead extraction: safety and efficacy
    Aytemir, K.
    Yorgun, H.
    Canpolat, U.
    Sahiner, M. L.
    Kaya, E. B.
    Evranos, B.
    Ozer, N.
    EUROPEAN HEART JOURNAL, 2015, 36 : 821 - 822
  • [5] Comparison between TightRail rotating dilator sheath and GlideLight laser sheath for transvenous lead extraction
    Qin, Dingxin
    Chokshi, Moulin
    Sabeh, Mohamad Khaled
    Maan, Abhishek
    Bapat, Aneesh
    Bode, Weeranun D.
    Hanley, Alan
    Hucker, William J.
    Ng, Chee Yuan
    Funamoto, Masaki
    Barrett, Conor D.
    Mela, Theofanie
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (05): : 895 - 902
  • [6] Comparison of Outcomes of Transvenous Lead Extraction Using an Excimer Laser Sheath vs the Tightrail Rotating Dilator Sheath
    Misra, Satish
    Swayampakala, Kamala
    Coons, Tricia
    Cerbie, Claire
    Lesiczka, Magdalena
    Holshouser, John W.
    Mehta, Rohit
    CIRCULATION, 2019, 140
  • [7] Transvenous extraction of a 26-year-old Accufix atrial lead using TightRail rotating dilator sheath
    Mammadli, Anar
    Vurgun, Veysel Kutay
    Yildirim, Onur
    Altin, Ali Timucin
    Candemir, Basar
    Akyurek, Omer
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2018, 46 (01): : 54 - 56
  • [8] Single center experience with the novel rotating dilator sheath TightRail™ Sub-C in transvenous lead extraction
    Frei, Celine
    Hofer, Daniel
    Jan, Steffel
    Grebmer, Christian
    Breitenstein, Alexander
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (08) : 1738 - 1743
  • [9] Use of the new rotating dilator sheath TightRail™ for lead extraction: A bicentric experience
    Mazzone, Patrizio
    Melillo, Francesco
    Radinovic, Andrea
    Marzi, Alssandra
    Paglino, Gabriele
    Della Bella, Paolo
    Mascioli, Giosue
    JOURNAL OF ARRHYTHMIA, 2020, 36 (02) : 343 - 350
  • [10] CURRENT PRACTICE AND APPLICATIONS OF TRANSVENOUS LEAD EXTRACTION USING EVOLUTION® MECHANICAL DILATOR SHEATH
    Oto, A.
    Aytemir, K.
    Canpolat, U.
    Yorgun, H.
    Kaya, E. B.
    Sahiner, L.
    Asil, S.
    Yalcin, U.
    Dural, M.
    Sunman, H.
    Kabakci, G.
    Tokgozoglu, L.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 163 : S48 - S49