Evaluation of right ventricular function by NuSMUGA software: gated blood-pool SPECT vs. first-pass radionuclide angiography

被引:0
|
作者
R.H.J.A. Slart
L. Poot
D.A. Piers
D.J. van Veldhuisen
P.L. Jager
机构
[1] University Hospital Groningen,Department of Nuclear Medicine
[2] University Hospital Groningen,Department of Cardiology
关键词
first-pass radionuclide angiography; gated blood-pool SPECT; right ventricular ejection fraction;
D O I
暂无
中图分类号
学科分类号
摘要
Background: In comparison with planar imaging gated blood-pool single photon emission computed tomography (GBPS) has the advantage of separating left and right ventricle. The purpose of this investigation was to evaluate the right ventricular ejection fraction (RVEF) calculations by GBPS software (‘NuSMUGA™’, Northwestern University, Chicago, IL) in comparison to first-pass radionuclide angiography (FPRNA). Methods: In 22 consecutive patients FPRNA and GBPS acquisition was performed. GBPS RVEF calculations were manually and automatically performed, using all gated short-axis-slices of the right ventricle. Results: Automatic RVEF assessed by GBPS did not correlate with conventional FPRNA (r = 0.40, p = 0.065). Mean FPRNA RVEF was 55 ± 10% and mean GBPS automatic RVEF was 32 ± 8%. Also manual GBPS RVEF did not correlate with conventional FPRNA (r = 0.41, p = 0.055). Mean RVEF measurement by manual GBPS was 33 ± 8%. Manual GBPS RVEF values correlated well with automatically determined GBPS RVEF values (r = 0.96, p < 0.0001). Conclusion: Automatic and manual values RVEF values assessed by GBPS did not correlate with conventional FPRNA values. FPRNA and GBPS calculations cannot be considered to be equivalent. Therefore the NuSMUGA program cannot be used to calculate RVEF.
引用
收藏
页码:401 / 407
页数:6
相关论文
共 50 条
  • [1] Evaluation of right ventricular function by NuSMUGA software: gated blood-pool SPECT vs. first-pass radionuclide angiography
    Slart, RHJA
    Poot, L
    Piers, DA
    van Veldhuisen, DJ
    Jager, PL
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2003, 19 (05): : 401 - 407
  • [2] Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography
    Seong-Jang Kim
    In-Ju Kim
    Yun-Seong Kim
    Yong-Ki Kim
    Yong Beom Shin
    Dong-Soo Kim
    Journal of Nuclear Cardiology, 2005, 12 : 553 - 559
  • [3] Automatic quantification of right ventricular volumes and right ventricular ejection fraction with gated blood pool SPECT: Comparison of 8- and 16-frame gated blood pool SPECT with first-pass radionuclide angiography
    Kim, SJ
    Kim, IJ
    Kim, YS
    Kim, YK
    Shin, YB
    Kim, DS
    JOURNAL OF NUCLEAR CARDIOLOGY, 2005, 12 (05) : 553 - 559
  • [4] Right-sided cardiac function in healthy volunteers measured by first-pass radionuclide ventriculography and gated blood-pool SPECT:: Comparison with cine MRI
    Kjær, A
    Lebech, AM
    Hesse, B
    Petersen, CL
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2005, 25 (06) : 344 - 349
  • [5] Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters: validation with first-pass radionuclide angiography
    Lee, Jung S.
    Lee, Jun S.
    Kim, Seong-Jang
    Kim, In-Ju
    Kim, Yong-Ki
    Choo, Ki S.
    ANNALS OF NUCLEAR MEDICINE, 2007, 21 (03) : 159 - 166
  • [6] Gated blood-pool SPECT assessment of right ventricular function.
    Hitzel, A
    Derumeaux, G
    Cribier, A
    Véra, P
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 196P - 196P
  • [7] Comparison of gated blood pool SPECT and spiral multidetector computed tomography in the assessment of right ventricular functional parameters: validation with first-pass radionuclide angiography
    Jung S. Lee
    Jun S. Lee
    Seong-Jang Kim
    In-Ju Kim
    Yong-Ki Kim
    Ki S. Choo
    Annals of Nuclear Medicine, 2007, 21 : 159 - 166
  • [8] Repeatability of left and right ventricular function measured with ECG-gated blood-pool SPECT versus planar radionuclide cardiac angiography
    Daou, D
    Coaguila, C
    Pointurier, I
    Helal, BO
    Fourme, T
    Carel, I
    Lebtahi, R
    Faraggi, M
    Slama, M
    Le Guludec, D
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (08): : 1039 - 1039
  • [9] Evaluation of right ventricular function in advanced heart failure: gated blood-pool SPECT ventriculography
    Havlenova, T. Tereza
    Tupy, M.
    Mlateckova, L.
    Buncova, M.
    Ters, J.
    Kidery, J.
    Netuka, I.
    Kautzner, J.
    Melenovsky, V.
    EUROPEAN JOURNAL OF HEART FAILURE, 2018, 20 : 578 - 579
  • [10] Repeatability of left and right ventricular function measured with egg-gated blood-pool spect versus planar radionuclide cardiac angiography.
    Daou, D
    Coaguila, C
    Helal, BO
    Fourme, T
    Carel, I
    Slama, M
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 137P - 138P