Characteristics of dust-collection efficiency and ozone emission by high-voltage electrode shape of electrostatic precipitator for subway tunnel environment

被引:0
|
作者
Sang-Hee Woo
Jae-In Lee
Jong Bum Kim
Gwi-Nam Bae
Seung-Bok Lee
Se-Jin Yook
Youhwan Shin
机构
[1] Korea Institute of Machinery and Materials,Engine Research Laboratory
[2] Korea Institute of Science and Technology,Center for Environment, Health and Welfare Research
[3] Korea Institute of Science and Technology,Center for Particulate Air Pollution and Health
[4] Hanyang University,School of Mechanical Engineering
[5] Korea Institute of Science and Technology,National Agenda Research Division
关键词
Electrostatic precipitator; Subway particle; Electrode shape; Ozone emission;
D O I
暂无
中图分类号
学科分类号
摘要
The air pollution level of particulate matters in subway tunnel environments is severe. The present study conducted experimental measurements and analyses on dust-collection efficiencies and ozone emission rates in a lab-scale wind tunnel to determine a high-voltage electrode shape suitable for an electrostatic precipitator to remove airborne particles in subway tunnels. Six high-voltage electrode shapes (saw-type, few-saw-type, short-saw-type, tree-type, wave-type, and spike-type) were tested. The results indicate that while breakdown voltage of the spike-type high-voltage electrode was 66 % of other electrode shapes, its dust-collection efficiency per unit voltage was similar to that of other electrode shapes. However, the dust-collection efficiency per unit of power in the spike-type high-voltage electrode was significantly low. Moreover, the wave-type high-voltage electrode shape had 20 % lower dust-collection efficiency than the saw-type and tree-type high-voltage electrode shapes under conditions of low voltage and high flow velocities. Ozone emission rates for all shapes increased proportionally to the electric current. However, ozone emission rates for each high-voltage electrode shape are varied as 12–23 μg/s per mA. The saw-type and tree-type high-voltage electrode shapes were superior in terms of dust collection, 90 % collection efficiency was shown at about 1.5 W/(m/s)2. The saw-type had a lower ozone emission rate (16.4 μg/s per mA) than the tree-type (19.6 μg/s per mA). Thus, the saw-type shape was the most suitable as a high-voltage electrode in the electrostatic precipitator for removing airborne particles in a subway. The results also indicate that both dust-collection efficiencies and ozone emission rates should be evaluated concurrently when evaluating electrostatic precipitator high-voltage electrodes.
引用
收藏
页码:1351 / 1363
页数:12
相关论文
共 9 条
  • [1] Characteristics of dust-collection efficiency and ozone emission by high-voltage electrode shape of electrostatic precipitator for subway tunnel environment
    Woo, Sang-Hee
    Lee, Jae-In
    Kim, Jong Bum
    Bae, Gwi-Nam
    Lee, Seung-Bok
    Yook, Se-Jin
    Shin, Youhwan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (03) : 1351 - 1363
  • [2] Effect of High-Voltage Electrostatic Precipitator Dust Collection Plate Structure on Collection Efficiency
    Ning, Liwei
    Wang, Nan
    Fu, Jun
    Ma, Yi
    Gu, Shuo
    Cheng, Milan
    ACS OMEGA, 2024, 9 (35): : 37396 - 37407
  • [3] Effects of high-voltage power sources on fine particle collection efficiency with an industrial electrostatic precipitator
    Zhu, Jibao
    Zhao, Qinxia
    Yao, Yuping
    Luo, Shikai
    Guo, Xiaochuan
    Zhang, Xuming
    Zeng, Yuxuan
    Yan, Keping
    JOURNAL OF ELECTROSTATICS, 2012, 70 (03) : 285 - 291
  • [4] Optimization of pipe-and-spike discharge electrode shape for improving electrostatic precipitator collection efficiency
    Lee, Gi-Hyuk
    Hwang, So-Young
    Cheon, Tae-Won
    Kim, Hak-Joon
    Han, Bangwoo
    Yook, Se-Jin
    POWDER TECHNOLOGY, 2021, 379 : 241 - 250
  • [5] Effect of collection efficiency and reducing ozone generation in an electrostatic precipitator with knife edge disk type electrode
    Zukeran, Akinori
    Ikeda, Yuto
    Mashimo, Fumiki
    Yasumoto, Koji
    Matsumoto, Masahiro
    Matsumoto, Noboru
    JOURNAL OF ELECTROSTATICS, 2023, 125
  • [6] Experimental study of a High Voltage (HV) electrostatic precipitator to achieve higher collection efficiency
    Sayem, A. S. M.
    Khan, M. M. K.
    Rasul, M. G.
    Wolfs, Peter
    Hassan, N. M. S.
    Sneath, Ben
    2017 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING CONFERENCE (AUPEC), 2017,
  • [7] High-voltage electrode position:: A key factor of electrostatic separation efficiency
    Aman, F
    Morar, R
    Köhnlechner, R
    Samuila, A
    Dascalescu, L
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2004, 40 (03) : 905 - 910
  • [8] High-voltage electrode position:: A key factor of electrostatic separation efficiency
    Aman, F
    Morar, R
    Köhnlechner, R
    Samuila, A
    Dascalescu, L
    CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, : 1418 - 1423
  • [9] INFLUENCE OF A PULSE DURATION OF HIGH-VOLTAGE SUPPLY ON THE EFFICIENCY OF OZONE SYNTHESIS IN THE "NEEDLE - PLANE" ELECTRODE SYSTEM
    Golota, V. I.
    Zavada, L. M.
    Karas, V. I.
    Kotjukov, O. V.
    Poliakov, O. V.
    Pugach, S. G.
    UKRAINIAN JOURNAL OF PHYSICS, 2007, 52 (02): : 147 - 154