Changes in dissolved oxygen concentration in an aerated drip irrigation system under different drip emitters

被引:0
|
作者
Jie Pang
Fukui Gao
Abdoul Kader Mounkaila Hamani
Huanhuan Li
Hao Liu
Rangjian Qiu
机构
[1] Ministry of Agriculture and Rural Affairs,Farmland Irrigation Research Institute, Chinese Academy of Agricultural Sciences/Key Laboratory for Crop Water Requirement and Regulation
[2] Wuhan University,State Key Laboratory of Water Resources and Hydropower Engineering Science
来源
Irrigation Science | 2023年 / 41卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The drip emitter type used influences the dissolved oxygen concentration (DOC) distribution in a drip irrigation system. Understanding the spatial and temporal DOC distribution in the irrigation system and its change pattern and determining the optimal irrigation emitter and aeration concentration threshold are important to reasonably apply aerated irrigation. Here, we designed three common drip irrigation emitter treatments under a drip irrigation system, i.e., an inserted in-line labyrinth emitter with a flow rate of 1.0 L h−1 (T1) and 2.2 L h−1 (T2), respectively, and a pressure-compensating emitter with a flow rate of 2.0 L h−1 (T3). Each irrigation emitter was associated with five initial DOC treatments, i.e., 3–5 mg L−1 (CK), 10 mg L−1 (C1), 15 mg L−1 (C2), 20 mg L−1 (C3), and 25 mg L−1 (C4). The results showed that the DOC values gradually increased in nonaerated water (CK) but gradually decreased in aerated water with standing time. Each emitter type significantly increased the DOC values after nonaerated water (CK) passed through different drip irrigation systems, and the highest increase (73.7%) was observed in the T1CK treatment. However, the DOC values significantly decreased after the aerated water passed through the drip irrigation systems, especially in the T2 treatment (33.2%). In addition, the reduction (or increase) in DOC in aerated water (or nonaerated water) in the first 10 m of the capillary pipe was smaller than that in the last 10 m for all treatments except T1C1. Furthermore, the T3 treatment had the most stable attenuation at different initial DOC treatments, with a maximum laying length of 20 m. More importantly, aeration can significantly increase DOC in the soil water (DOS), and the maximum value occurred when the initial DOC was 19.8 mg L−1. Hence, for practical application, the recommended initial DOC range for aerated irrigation is 15 ~ 20 mg L−1 combined with a pressure-compensating emitter at a flow rate of 2.0 L h−1 (T3). This study provides technical support for the optimal design and rational application of aerated drip irrigation systems.
引用
收藏
页码:749 / 759
页数:10
相关论文
共 50 条
  • [1] Changes in dissolved oxygen concentration in an aerated drip irrigation system under different drip emitters
    Pang, Jie
    Gao, Fukui
    Hamani, Abdoul Kader Mounkaila
    Li, Huanhuan
    Liu, Hao
    Qiu, Rangjian
    [J]. IRRIGATION SCIENCE, 2023, 41 (06) : 749 - 759
  • [2] Increasing dissolved oxygen concentration of irrigation water is beneficial to nitrogen uptake of cotton under mulched drip irrigation
    Wang, Tianyu
    Zhang, Jinzhu
    Dhital, Yam
    Ma, Kai
    Wen, Yue
    Wang, Zhenhua
    [J]. FIELD CROPS RESEARCH, 2024, 316
  • [3] Biological treatment of clogged emitters in a drip irrigation system
    Sahin, Ü
    Anapali, Ö
    Dönmez, MF
    Sahin, F
    [J]. JOURNAL OF ENVIRONMENTAL MANAGEMENT, 2005, 76 (04) : 338 - 341
  • [4] Irrigation Water Use Efficiency and Yield of Pistachio under Aerated Subsurface Drip Irrigation System
    Seifi, A.
    Mirlatifi, S. M.
    [J]. JOURNAL OF AGRICULTURAL SCIENCE AND TECHNOLOGY, 2020, 22 (06): : 1655 - 1671
  • [5] Study on effects of temperature changes on emitters outflow of drip irrigation
    Delghandi, Mahdi
    Behzad, Majeed
    Broomandnasab, Saeed
    Saeedinia, Mehri
    [J]. RESEARCH ON CROPS, 2011, 12 (02) : 600 - 606
  • [6] ANALYSIS OF IRRIGATION SYSTEM "DRIP BY DRIP"
    Simonovic, Vojislav
    Markovic, Dragan
    Markovic, Ivana
    Cebela, Zarko
    [J]. MACHINE AND INDUSTRIAL DESIGN IN MECHANICAL ENGINEERING, SEVENTH INTERNATIONAL SYMPOSIUM, KOD 2012, 2012, : 449 - 452
  • [7] Aerated drip irrigation increased the emitter clogging risk of the Yellow River water drip irrigation
    Lv, Chang
    Zhang, Erxin
    Gan, Haicheng
    Niu, Wenquan
    Ali, Sajjad
    Dong, Aihong
    Zhang, Wenqian
    Wu, Menglong
    Sun, Dan
    [J]. IRRIGATION AND DRAINAGE, 2023, 72 (01) : 3 - 20
  • [8] Variation in the flow rate of drip emitters in a subsurface irrigation system for different soil types
    Barros Nogueira, Virgilio Henrique
    Diotto, Adriano Valentim
    Thebaldi, Michael Silveira
    Colombo, Alberto
    Silva, Yasmin Fernandes
    de Castro Lima, Elvis Marcio
    Lima Resende, Gabriel Felipe
    [J]. AGRICULTURAL WATER MANAGEMENT, 2021, 243
  • [9] Selection of suitable drip-emitters for Yellow River water drip irrigation
    Liu, Lu
    Hou, Peng
    Liu, Zeyuan
    Wu, Naiyang
    Li, Weishan
    Wu, Ruonan
    Wang, Haijun
    Ma, Yongjiu
    Li, Yunkai
    [J]. Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2021, 37 (06): : 99 - 107
  • [10] Dynamic changes in bubble profile due to surfactant and tape orientation of emitters in drip tape during aerated water irrigation
    Bhattarai, S. P.
    Balsys, R. J.
    Eichler, P.
    Midmore, D. J.
    Wassink, D.
    [J]. INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2015, 75 : 137 - 143