Analysis of low-level 129I in brine using accelerator mass spectrometry

被引:0
|
作者
Ning Chen
Xiaolin Hou
Weijian Zhou
Yukun Fan
Qi Liu
机构
[1] Institute of Earth Environment,Xi’an AMS Center, State Key Laboratory of Loess and Quaternary Geology
[2] Chinese Academy of Sciences,undefined
[3] Xi’an JiaoTong University,undefined
[4] University of Chinese Academy of Science,undefined
关键词
Iodine-129; Radiochemical separation; Accelerator mass spectrometry; Oil field water; Brine; Geological dating;
D O I
暂无
中图分类号
学科分类号
摘要
An improved solvent extraction procedure for iodine separation from brine samples has been applied at Xi’an Accelerator Mass Spectrometry (AMS) center. Oil in the brine sample has to be removed to avoid appearance of the third phase during solvent extraction and to improve the chemical yield of iodine. The small amount of oil remained in the water phase was first removed by phase separation through settling down sufficiently based on their immiscibility, and then by filtration through a cellulose filter, on which oil was absorbed and removed. After oil removed, extraction recovery of iodine could achieve more than 90 %. The sodium bisulfite as an effective reductant should be added before acidification to avoid loss of iodine by formation of I2 in sample via reaction of iodate and iodide at pH 1–2, and then pH was adjusted to 1–2 to reduce the iodate to iodide followed by oxidation of iodide to I2 and solvent extraction to separate all inorganic iodine. As a pre-nuclear era sample, 129I/127I ratio in brine is normally more than two orders of magnitude lower than that in present surface environmental samples, so prevention of cross-contamination and memory effect in apparatus during processing procedure are very critical for obtaining reliable results, and monitoring the procedure blank is very important for analytical quality of 129I. The 129I/127I isotopic ratio in the brine samples and procedure blank of iodine reagents were measured to be (1.9–2.7) × 10−13 and 2.08 × 10−13, respectively, 3–4 orders of magnitudes lower than that in environmental samples in Xi’an, and the result of procedure blank is in the same level as the previous experiments in past 3 years, indicating contamination is not observed in our method.
引用
收藏
页码:1965 / 1971
页数:6
相关论文
共 50 条
  • [1] Analysis of low-level 129I in brine using accelerator mass spectrometry
    Chen, Ning
    Hou, Xiaolin
    Zhou, Weijian
    Fan, Yukun
    Liu, Qi
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2014, 299 (03) : 1965 - 1971
  • [2] Accelerator mass spectrometry analysis of 129I
    Liu, Qi
    Zhou, Weijian
    Hou, Xiaolin
    Fu, Yunchong
    Zhao, Wennian
    Lu, Xuefeng
    Chen, Ning
    Zhang, Luyuan
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2013, 25 (08): : 2085 - 2090
  • [3] Identification of 129I interferences in accelerator mass spectrometry
    Xu, Sheng
    Freeman, Stewart P. H. T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 438 : 96 - 100
  • [4] Accelerator mass spectrometry of 129I:: Technique and applications
    Kieser, WE
    Zhao, XL
    Soto, CY
    Tracy, B
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 263 (02) : 375 - 379
  • [5] ACCELERATOR MASS SPECTROMETRY OF 129I AT ISOTRACE.
    Kilius, L.R.
    Rucklidge, J.C.
    Litherland, A.E.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1987, B29 (1-2) : 72 - 76
  • [6] Rapid Analysis of 129I in Natural Water Samples Using Accelerator Mass Spectrometry
    Zhang, Mengting
    Hou, Xiaolin
    Zhang, Zhiyong
    Zhang, Luyuan
    Chen, Ning
    Fang, Miao
    ATOMIC SPECTROSCOPY, 2021, 42 (04) : 190 - 196
  • [7] Determination of 129I in atmospheric samples by accelerator mass spectrometry
    López-Gutiérrez, JM
    García-León, M
    Schnabel, C
    Schmidt, A
    Michel, R
    Synal, HA
    Suter, M
    APPLIED RADIATION AND ISOTOPES, 1999, 51 (03) : 315 - 322
  • [8] Analysis and environmental application of 129I at the Xi'an Accelerator Mass Spectrometry Center
    Zhou, Weijian
    Chen, Ning
    Hou, Xiaolin
    Zhang, Luyuan
    Liu, Qi
    He, Chaohui
    Fan, Yukun
    Luo, Maoyi
    Zhao, Yaolin
    Wang, Zhiwen
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 294 : 147 - 151
  • [9] Determination of 129I with accelerator-mass-spectrometry technique
    China Inst of Atomic Energy, Beijing, China
    Yuanzineng Kexue Jishu, 4 (301-305):
  • [10] Speciation analysis of 129I in seawater using coprecipitation and accelerator mass spectrometry and its applications
    Xing, Shan
    Hou, Xiaolin
    Aldahan, Ala
    Possnert, Goran
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2017, 311 (01) : 833 - 841