Blood pressure cutoffs for white-coat and masked effects in a large population undergoing home blood pressure monitoring

被引:0
|
作者
Audes D. M. Feitosa
Marco A. Mota-Gomes
Weimar S. Barroso
Roberto D. Miranda
Eduardo C. D. Barbosa
Rodrigo P. Pedrosa
Paula C. Oliveira
Camila L. D. M. Feitosa
Andréa A. Brandão
José L. Lima-Filho
Andrei C. Sposito
Antonio Coca
Wilson Nadruz
机构
[1] Federal University of Pernambuco,Laboratory of Immunopathology Keizo Asami
[2] University of Pernambuco,Pronto Socorro Cardiológico de Pernambuco (PROCAPE)
[3] MCor,Department of Internal Medicine
[4] Memorial São José Hospital–Rede D´Or São Luiz,Hypertension League
[5] State University of Health Sciences of Alagoas,Geriatrics Division
[6] CESMAC University Center,School of Medicine
[7] Federal University of Goiás,Department of Internal Medicine, School of Medical Sciences
[8] Federal University of São Paulo,Hypertension and Vascular Risk Unit, Department of Internal Medicine, Hospital Clínic (IDIBAPS) Effect
[9] Hypertension League of Porto Alegre,undefined
[10] RealCor,undefined
[11] Royal Portuguese Hospital of Charity in Pernambuco,undefined
[12] State University of Rio de Janeiro,undefined
[13] State University of Campinas,undefined
[14] University of Barcelona,undefined
来源
Hypertension Research | 2019年 / 42卷
关键词
Home blood pressure; White-coat hypertension; Masked hypertension;
D O I
暂无
中图分类号
学科分类号
摘要
The values used to define the presence of white-coat or masked blood pressure (BP) effects are arbitrary. The aim of this study was to investigate the accuracy of several cutoff points based on the difference between office and home BP (ΔBP) values to detect white-coat uncontrolled (WUCH) and masked uncontrolled (MUCH) hypertension, which are phenotypes with adverse prognoses, in a large cohort of treated hypertensive patients. This multicenter cross-sectional study included 6,049 treated hypertensive patients (40% males, mean age 59.1 ± 14.4 years) who underwent office and home BP monitoring. We compared the sensitivity, specificity, area under curve (AUC), and positive (PPV) and negative (NPV) predictive values of several ΔBP cutoffs to detect WUCH and MUCH. The 15/9 mmHg cutoff, which reflects a 1.0 standard deviation of the ΔBP, showed the best AUC (0.783, 95% CI = 0.772–0.794) for the detection of WUCH, particularly in individuals with office grade 1 hypertension (AUC = 0.811, 95% CI = 0.793–0.829). The −1/−1 mmHg cutoff, which considers all individuals who had lower systolic or diastolic BP levels in the office than at home, had the highest AUC (0.822, 95% CI = 0.808–0.836) for the detection of MUCH. Both cutoff values also had the best performances for identifying all patients with higher and lower office-than-home BP grades. In conclusion, the 15/9 and −1/−1 mmHg cutoffs showed the best performance for the detection of treated hypertensive patients with WUCH and MUCH, respectively, and therefore might be markers of significant white-coat and masked effects and could be useful for identifying preferential targets for more routine home BP measures.
引用
收藏
页码:1816 / 1823
页数:7
相关论文
共 50 条
  • [1] Blood pressure cutoffs for white-coat and masked effects in a large population undergoing home blood pressure monitoring
    Feitosa, Audes D. M.
    Mota-Gomes, Marco A.
    Barroso, Weimar S.
    Miranda, Roberto D.
    Barbosa, Eduardo C. D.
    Pedrosa, Rodrigo P.
    Oliveira, Paula C.
    Feitosa, Camila L. D. M.
    Brandao, Andrea A.
    Lima-Filho, Jose L.
    Sposito, Andrei C.
    Coca, Antonio
    Nadruz, Wilson
    HYPERTENSION RESEARCH, 2019, 42 (11) : 1816 - 1823
  • [2] Cutoffs for white-coat and masked blood pressure effects: an ambulatory blood pressure monitoring study
    Dal Pont, Christian S.
    Feitosa, Audes D. M.
    Bezerra, Rodrigo
    Martins, Arthur H. B.
    Viana, Gustavo M.
    Starke, Siegmar
    Azevedo, Guilherme S. A.
    Mota-Gomes, Marco A.
    Barroso, Weimar S.
    Miranda, Roberto D.
    Barbosa, Eduardo C. D.
    Brandao, Andrea A.
    Feitosa, Camila L. D. M.
    Goncalves, Thales A. T.
    Nobre, Fernando
    Mion Jr, Decio
    Sposito, Andrei C.
    Nadruz, Wilson
    JOURNAL OF HUMAN HYPERTENSION, 2024, 38 (08) : 595 - 602
  • [3] THRESHOLDS FOR WHITE-COAT AND MASKED BLOOD PRESSURE EFFECTS: AN AMBULATORY BLOOD PRESSURE MONITORING STUDY
    Dal Pont, Christian
    Feitosa, Audes D. M.
    Viana, Gustavo M.
    Starke, Siegmar
    Azevedo, Guilherme S. A.
    Mota, Marco A.
    Barroso, Weimar S.
    Miranda, Roberto D.
    Barbosa, Eduardo C. D.
    Brandao, Andrea
    Bezerra, Rodrigo
    Feitosa, Camila L. D. M.
    Goncalves, Thales A. T.
    Nobre, Fernando
    Mion, Decio, Jr.
    Sposito, Andrei
    Nadruz, Wilson
    JOURNAL OF HYPERTENSION, 2023, 41 : E8 - E8
  • [4] Accuracy of home versus ambulatory blood pressure monitoring in the diagnosis of white-coat and masked hypertension
    Kang, Yuan-Yuan
    Li, Yan
    Huang, Qi-Fang
    Song, Jie
    Shan, Xiao-Li
    Dou, Yu
    Xu, Xin-Juan
    Chen, Shou-Hong
    Wang, Ji-Guang
    JOURNAL OF HYPERTENSION, 2015, 33 (08) : 1580 - 1587
  • [5] ACCURACY OF HOME VERSUS AMBULATORY BLOOD PRESSURE MONITORING IN THE DIAGNOSIS OF WHITE-COAT AND MASKED HYPERTENSION
    Kang, Y.
    Li, Y.
    Huang, Q. E.
    Song, J.
    Shan, X. L.
    Dou, Y.
    Xu, X. J.
    Chen, S. H.
    Wang, J. G.
    JOURNAL OF HYPERTENSION, 2015, 33 : E7 - E7
  • [6] White-coat, masked and sustained hypertension detected by home blood pressure monitoring in adolescents: prevalence and associated factors
    Jardim, Thiago Veiga
    Carneiro, Carolina de Souza
    Morais, Polyana
    Roriz, Vanessa
    Mendonca, Karla Lorena
    Nascente, Flavia Miquetichuc
    Rolim Povoa, Thais Inacio
    Sebba Barroso, Weimar Kunz
    Lima Sousa, Ana Luiza
    Veiga Jardim, Paulo Cesar
    BLOOD PRESSURE, 2018, 27 (03) : 151 - 157
  • [7] Blood Pressure Measurement and Treatment Decisions Masked and White-Coat Hypertension
    Kario, Kazuomi
    Thijs, Lutgarde
    Staessen, Jan A.
    CIRCULATION RESEARCH, 2019, 124 (07) : 990 - 1008
  • [8] Home blood pressure self-monitoring:: diagnostic performance in white-coat hypertension
    Bayó, J
    Cos, FX
    Roca, C
    Dalfó, A
    Martín-Baranera, MM
    Albert, B
    BLOOD PRESSURE MONITORING, 2006, 11 (02) : 47 - 52
  • [9] Prognosis of White-Coat and Masked Hypertension International Database of Home Blood Pressure in Relation to Cardiovascular Outcome
    Stergiou, George S.
    Asayama, Kei
    Thijs, Lutgarde
    Kollias, Anastasios
    Niiranen, Teemu J.
    Hozawa, Atsushi
    Boggia, Jose
    Johansson, Jouni K.
    Ohkubo, Takayoshi
    Tsuji, Ichiro
    Jula, Antti M.
    Imai, Yutaka
    Staessen, Jan A.
    HYPERTENSION, 2014, 63 (04) : 675 - 682
  • [10] Impact of 2017 ACC/AHA hypertension guidelines on the prevalence of white-coat and masked hypertension: A home blood pressure monitoring study
    Feitosa, Audes D. M.
    Mota-Gomes, Marco A.
    Miranda, Roberto D.
    Barroso, Weimar S.
    Barbosa, Eduardo C. D.
    Pedrosa, Rodrigo P.
    Oliveira, Paula C.
    Feitosa, Camila L. D. M.
    Lima-Filho, Jose L.
    Sposito, Andrei C.
    Nadruz, Wilson
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (12): : 1745 - 1747