Trace determination of vanadium(V) using anodic adsorptive voltammetry at a glassy carbon electrode modified with multi-walled carbon nanotubes

被引:0
|
作者
Pei-Hong Deng
Jun-Jie Fei
Jun Zhang
Ju-Nan Li
机构
[1] Hengyang Normal University,Department of Chemistry and Material Science
[2] Xiangtan University,College of Chemistry
来源
Microchimica Acta | 2009年 / 165卷
关键词
Multi-walled carbon nanotubes; Modified electrode; Anodic adsorptive voltammetry; Vanadium;
D O I
暂无
中图分类号
学科分类号
摘要
A glassy carbon electrode modified with multi-walled carbon nanotubes (MWCNT) was prepared and the determination of trace amount of vanadium(V) based on the anodic adsorptive voltammetry of the vanadium-alizarin red S (ARS) complex is described for the first time. The results show that the sensitivity and the selectivity of the method are excellent. The second derivative linear scan voltammograms of the complex were recorded using a polarographic analyzer in the range from 0 to 1,000 mV (vs. SCE). It was found that the complex can be adsorbed on the surface of the electrode, yielding a peak at about 706 mV, corresponding to the oxidation of ARS in the complex. The peak current increases linearly with the V(V) concentration in the range of 6.0 nM to ∼1.0 μM (4.0 μM ARS), 2.0 μM∼10 μM (40 μM ARS) and the detection limit (at S/N = 3) was 2.0 nM (accumulation time 120 s). The method was successfully applied to the determination of trace amounts of vanadium in water samples.
引用
下载
收藏
页码:211 / 216
页数:5
相关论文
共 50 条
  • [1] Trace determination of vanadium(V) using anodic adsorptive voltammetry at a glassy carbon electrode modified with multi-walled carbon nanotubes
    Deng, Pei-Hong
    Fei, Jun-Jie
    Zhang, Jun
    Li, Ju-Nan
    MICROCHIMICA ACTA, 2009, 165 (1-2) : 211 - 216
  • [2] Trace determination of zirconium using anodic adsorptive voltammetry at a carbon paste electrode modified with multi-walled carbon nanotubes
    DENG PeiHong1
    2 College of Chemistry
    Science Bulletin, 2008, (11) : 1665 - 1670
  • [3] Trace determination of molybdenum by anodic adsorptive stripping voltammetry using a multi-walled carbon nanotubes modified carbon paste electrode
    Deng, Pei-Hong
    Fei, Jun-Jie
    Feng, Yong-Lan
    SENSORS AND ACTUATORS B-CHEMICAL, 2010, 148 (01): : 214 - 220
  • [4] DETERMINATION OF TRACE ALUMINUM BY ANODIC ADSORPTIVE STRIPPING VOLTAMMETRY USING A MULTI-WALLED CARBON NANOTUBE MODIFIED CARBON PASTE ELECTRODE
    Deng, Peihong
    Fei, Junjie
    Zhang, Jun
    Feng, Yonglan
    ANALYTICAL LETTERS, 2011, 44 (08) : 1521 - 1535
  • [5] Trace determination of zirconium using anodic adsorptive voltammetry at a carbon paste electrode modified with multi-waited carbon nanotubes
    Deng PeiHong
    Fei JunJie
    Zhang Jun
    Li JuNan
    CHINESE SCIENCE BULLETIN, 2008, 53 (11): : 1665 - 1670
  • [6] Determination of Creatinine in Urine by Voltammetry and Glassy Carbon Electrode Modified with Functionalized Multi-walled Carbon Nanotubes and Copper
    Pedrozo-Penafiel, Marlin J.
    Lopes, Thais
    Gutierrez-Beleno, Luis M.
    Miranda-Andrades, Jarol R.
    Maia Da Costa, Marcelo E. H.
    Larrude, Dunieskys G.
    Aucelio, Ricardo Q.
    ELECTROANALYSIS, 2023, 35 (02)
  • [8] Anodic stripping voltammetry of silver(I) using a carbon paste electrode modified with multi-walled carbon nanotubes
    Jahandari, Shokoofe
    Taher, Mohammad Ali
    Fazelirad, Hamid
    Sheikhshoai, Iran
    MICROCHIMICA ACTA, 2013, 180 (5-6) : 347 - 354
  • [9] Multi-walled carbon nanotubes modified glassy carbon electrode for sensitive determination of ketoconazole
    Borowiec, Joanna
    Wei, Lili
    Zhu, Lihua
    Zhang, Jingdong
    ANALYTICAL METHODS, 2012, 4 (02) : 444 - 448
  • [10] Anodic stripping voltammetry of silver(I) using a carbon paste electrode modified with multi-walled carbon nanotubes
    Shokoofe Jahandari
    Mohammad Ali Taher
    Hamid Fazelirad
    Iran Sheikhshoai
    Microchimica Acta, 2013, 180 : 347 - 354