Stable Isotope Labeling by Carbon-13 in Bacteria Culture for the Analysis of Residual Avermectin Using Stable Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry

被引:0
|
作者
Kodai Beppu
Daichi Saito
Yoshio Muguruma
Miki Takahashi
Shuichi Harada
Koichi Inoue
机构
[1] Ritsumeikan University,College of Pharmaceutical Sciences
[2] Hayashi Pure Chemical Ind.,undefined
[3] Ltd,undefined
来源
Analytical Sciences | 2021年 / 37卷
关键词
avermectin; residue assay; LC-MS/MS;
D O I
暂无
中图分类号
学科分类号
摘要
This study describes the development of a new stable isotope labeling method by carbon-13 in bacteria culture (SILCB) for the analysis of residual antibiotics via liquid chromatography with tandem mass spectrometry (LC-MS/MS). Stable isotope dilution (SID) LC-MS/MS with QuEChERS was employed to determine avermectin, particularly avermectin B1a (AV-a) and B1b (AV-b), based on completely 13C-labeled internal standards (13C-ISs) obtained from the SILCB. Our SILCB was developed from an optimal inorganic medium using 13C6-glucose for Streptomyces avermitilis (14893 strain). A rough extract containing 13C-ISs was purified via high-speed countercurrent chromatography with a volatile two-phase solvent system composed of n-hexane/ethyl acetate/methanol/0.5% formic acid in water (7/3/5/5/, V/V). The purified 13C-ISs were evaluated to confirm the presence of completely 13C-labeled ions with m/z 938 > 326 and m/z 923 > 309 for AV-a and AV-b, respectively. The QuEChERS approach with the 13C-ISs procedure achieved acceptable recovery rates in beef meat samples of 99.5–100.0% (RSD < 2.0%, n = 6). For the analysis of residual antibiotics in foodstuffs by SIDLC-MS/MS and QuEChERS, the SILCB represents a significant improvement over previous methods suffering from cumbersome sample preparation and matrix effects.
引用
收藏
页码:1385 / 1390
页数:5
相关论文
共 50 条
  • [1] Stable Isotope Labeling by Carbon-13 in Bacteria Culture for the Analysis of Residual Avermectin Using Stable Isotope Dilution Liquid Chromatography Tandem Mass Spectrometry
    Beppu, Kodai
    Saito, Daichi
    Muguruma, Yoshio
    Takahashi, Miki
    Harada, Shuichi
    Inoue, Koichi
    ANALYTICAL SCIENCES, 2021, 37 (10) : 1385 - 1390
  • [2] Quantification of dsRNA using stable isotope labeling dilution liquid chromatography/mass spectrometry
    Kung, An-Wen
    Kilby, Peter M.
    Portwood, David E.
    Dickman, Mark J.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (07) : 590 - 596
  • [3] Quantification of intracellular homocysteine by stable isotope dilution liquid chromatography/tandem mass spectrometry
    Huang, Yuehua
    Lu, Zhi-Yong
    Brown, Karen S.
    Whitehead, Alexander S.
    Blair, Ian A.
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (01) : 107 - 112
  • [4] A NEW STABLE ISOTOPE DILUTION APPROACH TO THE DETERMINATION OF SUCCINYLACETONE IN URINE USING LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY
    Rashed, M.
    Al-Dirbashi, O.
    ten Brink, H.
    Filimban, N.
    Al-Ahaidib, L.
    Al-Sayed, M.
    Al-Hassnan, Z.
    Rahbeeni, Z.
    Al-Owain, M.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2005, 28 : 70 - 70
  • [5] Quantification of melatonin in human saliva by liquid chromatography-tandem mass spectrometry using stable isotope dilution
    Eriksson, K
    Östin, A
    Levin, JO
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (01): : 115 - 123
  • [6] Stable Isotope Dilution Analysis of Gibberellin Residues in Tomato Paste by Liquid Chromatography-Tandem Mass Spectrometry
    SUN Li1
    2. School of Food and Biological Engineering
    3. Xinjiang Extry-exit Inspection and Quarantine Bureau
    Chemical Research in Chinese Universities, 2012, 28 (05) : 797 - 801
  • [7] Stable Isotope Dilution Analysis of Gibberellin Residues in Tomato Paste by Liquid Chromatography-Tandem Mass Spectrometry
    Sun Li
    Zhao Yan-sheng
    Nie Xue-mei
    Ling Yun
    Chu Xiao-gang
    Shang De-jun
    Dong Ying
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2012, 28 (05) : 797 - 801
  • [8] Stable isotope-dilution liquid chromatography/tandem mass spectrometry method for determination of thyroxine in saliva
    Higashi, Tatsuya
    Ichikawa, Takuya
    Shimizu, Chikara
    Nagai, So
    Inagaki, Shinsuke
    Min, Jun Zhe
    Chiba, Hitoshi
    Ikegawa, Shigeo
    Toyo'oka, Toshimasa
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (13-14): : 1013 - 1017
  • [9] Measurement of trimethylamine-N-oxide by stable isotope dilution liquid chromatography tandem mass spectrometry
    Wang, Zeneng
    Levison, Bruce S.
    Hazen, Jennie E.
    Donahue, Lillian
    Li, Xin-Min
    Hazen, Stanley L.
    ANALYTICAL BIOCHEMISTRY, 2014, 455 : 35 - 40
  • [10] Simultaneous detection of five one-carbon metabolites in plasma using stable isotope dilution liquid chromatography tandem mass spectrometry
    Adaikalakoteswari, Antonysunil
    Webster, Craig
    Goljan, Ilona
    Saravanan, Ponnusamy
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1012 : 186 - 192