Application of molecular imprinted polymer nanoparticles as a selective solid phase extraction for preconcentration and trace determination of 2,4-dichlorophenoxyacetic acid in the human urine and different water samples

被引:0
|
作者
Fariborz Omidi
Mohammad Behbahani
Hamid Sadeghi Abandansari
Alireza Sedighi
Seyed Jamaleddin Shahtaheri
机构
[1] Shahroud University of Medical Sciences,Department of Occupational Health Engineering, School of Public Health
[2] Shahid Beheshti University,Department of Chemistry
[3] Tehran University of Medical Sciences,Department of Occupational Health, School of Public Health
[4] Tehran University of Medical Sciences,Department of Occupational Health Engineering, School of Public Health and Institute for Environmental Research
关键词
Molecular imprinted polymer nanoparticles; 2,4-dichlorophenoxyacetic acid; Selective preconcentration; Urine and water samples;
D O I
暂无
中图分类号
学科分类号
摘要
A molecular-imprinted polymer nanoparticles (MIP-NP) for the selective preconcentration of 2,4-dichlorophenoxyacetic acid (2,4-D) is described. It was obtained by precipitation polymerization from methacrylic acid (the functional monomer), ethylene glycol dimethacrylate (the cross-linker), 2,2′-azobisisobutyronitrile (the initiator) and 2,4-D (the template molecule) in acetonitrile solution. The MIP-NPs were characterized by thermogravimetric analysis, and by scanning electron microscopy. Imprinted 2,4-D molecules were removed from the polymeric structure using acetic acid in methanol (15:85 v/v %) as the eluting solvent. The sorption and desorption process occur within 10 min and 15 min, respectively. The maximum sorbent capacity of the molecular imprinted polymer is 89.2 mg g−1. The relative standard deviation and limit of detection for water samples by introduced selective solid phase extraction were 4.2% and 1.25 μg L−1, and these data for urine samples were 4.7% and 1.80 μg L−1, respectively. The method was applied to the determination of 2,4-D in the urine and different water samples.
引用
收藏
相关论文
共 50 条
  • [1] Application of molecular imprinted polymer nanoparticles as a selective solid phase extraction for preconcentration and trace determination of 2,4-dichlorophenoxyacetic acid in the human urine and different water samples
    Omidi, Fariborz
    Behbahani, Mohammad
    Abandansari, Hamid Sadeghi
    Sedighi, Alireza
    Shahtaheri, Seyed Jamaleddin
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2014, 12
  • [2] Application of NaClO-treated multiwalled carbon nanotubes as solid phase extraction sorbents for preconcentration of trace 2,4-dichlorophenoxyacetic acid in aqueous samples
    Lu, Ping
    Deng, Dayi
    Ni, Xiaodan
    JOURNAL OF SEPARATION SCIENCE, 2012, 35 (17) : 2307 - 2312
  • [3] Selective recognition of 2,4-dichlorophenoxyacetic acid using a molecularly imprinted polymer
    Nomura, Y
    Muguruma, H
    Yano, K
    Kugimiya, A
    McNiven, S
    Ikebukuro, K
    Karube, I
    ANALYTICAL LETTERS, 1998, 31 (06) : 973 - 980
  • [5] Determination of 2,4-dichlorophenoxyacetic acid (2,4-D) in human urine with mass selective detection
    Hughes, DL
    Ritter, DJ
    Wilson, RD
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2001, 36 (06) : 755 - 764
  • [6] Development of a dipstick immunoassay for quantitative determination of 2,4-dichlorophenoxyacetic acid in water, fruit and urine samples
    N. V. Cuong
    T. T. Bachmann
    R. D. Schmid
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 584 - 589
  • [7] Development of a dipstick immunoassay for quantitative determination of 2,4-dichlorophenoxyacetic acid in water, fruit and urine samples
    Cuong, NV
    Bachmann, TT
    Schmid, RD
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (06): : 584 - 589
  • [8] Solid-phase extraction preconcentration of 2,4-dichlorophenoxyacetic acid on silica with immobilized polyethoxylated isooctylphenol groups
    Khalaf, V. A.
    Turchin, V. O.
    Grin'ko, A. P.
    Zaitsev, V. N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 64 (02) : 110 - 115
  • [9] Solid-phase extraction preconcentration of 2,4-dichlorophenoxyacetic acid on silica with immobilized polyethoxylated isooctylphenol groups
    V. A. Khalaf
    V. O. Turchin
    A. P. Grin’ko
    V. N. Zaitsev
    Journal of Analytical Chemistry, 2009, 64 : 110 - 115
  • [10] A molecularly imprinted polymer based monolith pipette tip for solid-phase extraction of 2,4-dichlorophenoxyacetic acid in an aqueous sample
    Wu, Beibei
    Muhammad, Turghun
    Aihebaier, Sailemayi
    Karim, Kal
    Hu, Yiting
    Piletsky, Sergey
    ANALYTICAL METHODS, 2020, 12 (40) : 4913 - 4921