Comparison of dose distributions for Hounsfield number conversion methods in GEANT4

被引:0
|
作者
Hyung Dong Kim
Byung Yong Kim
Eng Chan Kim
Sang Mo Yun
Jeong Ku Kang
Sung Kyu Kim
机构
[1] Yeungnam University,Department of Physics
[2] Daegu Fatima Hospital,Department of Radiation Oncology
[3] Presbyterian Medical Center,Department of Radiation Oncology
[4] Yeungnam University College of Medicine,Department of Radiation Oncology
来源
关键词
GEANT4; Monte Carlo; CT number conversion; Material assignment;
D O I
暂无
中图分类号
学科分类号
摘要
The conversion of patient computed tomography (CT) data to voxel phantoms is essential for CT-based Monte Carlo (MC) dose calculations, and incorrect assignments of materials and mass densities can lead to large errors in dose distributions. We investigated the effects of mass density and material assignments on GEANT4-based photon dose calculations. Three material conversion methods and four density conversion methods were compared for a lung tumor case. The dose calculations for 6-MV photon beams with a field size of 10 × 10 cm2 were performed using a 0.5 × 0.5 × 0.5 cm3 voxel with 1.2 × 109 histories. The material conversion methods led to different material assignment percentages in converted voxel regions. The GEANT4 example and the modified Schneider material conversion methods showed large local dose differences relative to the BEAMnrc default method for lung and other tissues. For mass density conversion methods when only water was used, our results showed only slight dose differences. Gaussian-like distributions, with mean values close to zero, were obtained when the reference method was compared with the other methods. The maximum dose difference of ∼2% indicated that the dose distributions agreed relatively well. Material assignment methods probably have more significant impacts on dose distributions than mass density assignment methods. The study confirms that material assignment methods cause significant dose differences in GEANT4-based photon dose calculations.
引用
收藏
页码:1912 / 1918
页数:6
相关论文
共 50 条
  • [1] Comparison of dose distributions for Hounsfield number conversion methods in GEANT4
    Kim, Hyung Dong
    Kim, Byung Yong
    Kim, Eng Chan
    Yun, Sang Mo
    Kang, Jeong Ku
    Kim, Sung Kyu
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 64 (12) : 1912 - 1918
  • [2] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (04) : 896 - 901
  • [3] Verification of the dose distributions with GEANT4 simulation for proton therapy
    Aso, T
    Kimura, A
    Tanaka, S
    Yoshida, H
    Kanematsu, N
    Sasaki, T
    Akagi, T
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2138 - 2142
  • [4] Inter-comparison of Dose Distributions Calculated by FLUKA, GEANT4, MCNP, and PHITS for Proton Therapy
    Yang, Zi-Yi
    Tsai, Pi-En
    Lee, Shao-Chun
    Liu, Yen-Chiang
    Chen, Chin-Cheng
    Sato, Tatsuhiko
    Sheu, Rong-Jiun
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [5] DOSE CALIBRATOR MODELLING WITH GEANT4
    O'Keefe, G.
    INTERNAL MEDICINE JOURNAL, 2018, 48 : 10 - 11
  • [6] Comparison of MuScat data with GEANT4
    Murray, WJ
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2005, 149 : 99 - 103
  • [7] Geant4 Benchmarking for IMRT Dose Calculations
    Hancox, C.
    Seco, J.
    Paganetti, H.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [8] Comparison of electron scattering algorithms in Geant4
    Sawkey, D.
    Constantin, M.
    Svatos, M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11): : 3249 - 3258
  • [9] Pencil Beam Algorithm on the GEANT4 Based Simulation Framework and Verification of the Dose Distributions for Proton Therapy
    Aso, Tsukasa
    Yamashita, Tomohiro
    Akagi, Takashi
    Sasaki, Takashi
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2166 - +
  • [10] Dependence of the Depth-Dose Distributions and Ranges of Proton Beams in Water Medium on Geant4 Parameters
    Tok, A.
    Bektasoglu, M.
    Arslan, H.
    ACTA PHYSICA POLONICA A, 2016, 130 (01) : 438 - 440