Effect of flow-rate on ethanol separation in membrane distillation process

被引:0
|
作者
Marek Gryta
机构
[1] West Pomeranian University of Technology,Institute of Chemical and Environment Engineering
来源
Chemical Papers | 2013年 / 67卷
关键词
membrane distillation; bioreactor; ethanol fermentation;
D O I
暂无
中图分类号
学科分类号
摘要
The separation of diluted ethanol solutions and fermentation broths by membrane distillation was investigated. The influence of stream flow-rate on the ethanol flux was studied. An evaluation of the process conditions on the separation degree of ethanol was performed with the application of hydrophobic capillary membranes composed of polypropylene. By removing the alcohol via membrane distillation, it is possible to achieve a higher content of ethanol in the permeate than that in the broth. The enrichment coefficient amounted to 4–6.5, and decreased with an increase of the ethanol concentration in the broth. It was found that the flow-rate affects the value of the enrichment coefficient. A positive influence of carbon dioxide on the ethanol transport through the capillary membrane was observed. The evolution of CO2 bubbles from the broth increases the stream turbulence, probably enhancing the alcohol concentration in the layer adjacent to the membrane surface.
引用
收藏
页码:1201 / 1209
页数:8
相关论文
共 50 条
  • [1] Effect of flow-rate on ethanol separation in membrane distillation process
    Gryta, Marek
    [J]. CHEMICAL PAPERS, 2013, 67 (09) : 1201 - 1209
  • [2] The investigation of ethanol separation by the membrane distillation process
    Tomaszewska, Maria
    Bialonczyk, Lidia
    [J]. POLISH JOURNAL OF CHEMICAL TECHNOLOGY, 2011, 13 (03) : 66 - 69
  • [3] A flow-rate and conductivity transducer for centrifuge-borne membrane process measurements
    Byrnes, PWG
    Wild, PM
    Bergen, A
    Vickers, GW
    Fyles, TM
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2000, 11 (10) : 1440 - 1446
  • [4] DISTRIBUTIONS OF PRESSURE AND FLOW-RATE IN A HOLLOW-FIBER MEMBRANE MODULE FOR PLASMA SEPARATION
    YOSHIKAWA, S
    OGAWA, K
    MINEGISHI, S
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1994, 27 (03) : 385 - 390
  • [5] STUDIES OF DIALYSIS - MEMBRANE PERFORMANCE FOR VARIOUS SOLUTES AND EFFECT OF FLOW-RATE ON MEMBRANE PERFORMANCE
    YUMOTO, S
    OHYA, H
    [J]. KAGAKU KOGAKU RONBUNSHU, 1982, 8 (02) : 150 - 154
  • [6] ESTIMATION OF THE FLOW-RATE OF THE SEPARATING AGENT IN EXTRACTIVE AND AUTOEXTRACTIVE DISTILLATION
    FROLKOVA, AK
    PAVLENKO, TG
    TIMOFEEV, VS
    [J]. JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1987, 60 (03): : 594 - 597
  • [7] FLOW-RATE DEPENDENCE OF SEPARATION AND BROADENING EFFECTS IN GPC
    GAO, YS
    YE, ML
    LE, HJ
    DING, YK
    YING, QC
    SANG, MM
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1982, 5 (07): : 1241 - 1267
  • [8] SEPARATION IN A GAS CENTRIFUGE AT HIGH FEED FLOW-RATE
    CUNZHEN, Z
    CONLISK, AT
    [J]. JOURNAL OF FLUID MECHANICS, 1989, 208 : 355 - 373
  • [9] Membrane distillation for dilute ethanol - Separation from aqueous streams
    Banat, FA
    Simandl, J
    [J]. JOURNAL OF MEMBRANE SCIENCE, 1999, 163 (02) : 333 - 348
  • [10] Effect of module design and flow patterns on performance of membrane distillation process
    Ali, A.
    Aimar, P.
    Drioli, E.