Electrical resistivity methods to characterize the moisture content in Brazilian sanitary landfill

被引:0
|
作者
Nataly Aranda
Vagner R. Elis
Renato L. Prado
Miriam G. Miguel
Mariane Alves de Godoy Leme
Bruno Conicelli
Oswaldo Guzmán
机构
[1] University of São Paulo ,Geophysical Department
[2] Universidad Regional Amazonica Ikiam , Institute of Astronomy, Geophysics and Atmospheric Sciences
[3] University of Campinas (Unicamp),School of Civil Engineering, Architecture and Urban Design
来源
关键词
Municipal solid waste; Electrical resistivity tomography; Vertical electrical sounding; Archie's law; Moisture content;
D O I
暂无
中图分类号
学科分类号
摘要
The moisture content of the municipal solid waste (MSW) is a physical characteristic that plays a fundamental role in the stability and settlement of landfills. However, this physical index is difficult to monitor within the mass of landfilled MSW because it undergoes great variation due, mainly, to the heterogeneity and biodegradation of the waste. Brazilian MSW generally has a large amount of organic matter, that when biodegraded, generates a considerable volume of gases and fluids, aggravated by climatic conditions, such as high rainfall and temperatures. Hence, the importance of obtaining and evaluating the distribution of moisture content in the MSW mass over time. Currently, the electrical resistivity properties have been presented as an interesting approach to obtain the moisture content in landfills indirectly. This study aimed to apply geoelectrical methods as a tool to obtain and evaluate the moisture content distribution in an experimental cell of a sanitary landfill using Archie’s law, which correlates the volumetric moisture content and electrical resistivity. Moisture content values were obtained in laboratory tests with MSW samples collected in two vertical holes and electrical resistivity measurements by means of vertical electrical sounding. The moisture content and the resistivity values of the samples were used to calculate the parameters a and m of Archie’s law. This allowed to convert the resistivity tomography to moisture content tomography. The good correlation achieved between the moisture content calculated by Archie’s law and that obtained from samples indicates that the use of electrical resistivity methods is useful to assess and monitor quantitatively the moisture content in landfills using Archie’s law.
引用
收藏
相关论文
共 50 条
  • [1] Electrical resistivity methods to characterize the moisture content in Brazilian sanitary landfill
    Aranda, Nataly
    Elis, Vagner R.
    Prado, Renato L.
    Miguel, Miriam G.
    Alves de Godoy Leme, Mariane
    Conicelli, Bruno
    Guzman, Oswaldo
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2021, 193 (05)
  • [2] Correlation between electrical resistivity and moisture content of municipal solid waste in Bioreactor landfill
    University of Illinois at Chicago, Department of Civil and Materials Engineering, Chicago, IL 60607
    不详
    不详
    Geotech Spec Publ, 2007, 163
  • [3] Electrical resistivity-based approach to characterize moisture content in compressed earth bricks
    Nguyen, Tuan Anh
    Pham, Minh Dung
    Hafsa, Wael
    Angellier, Nicolas
    Ulmet, Laurent
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2024, 21
  • [4] The use of electrical resistivity tomography and borehole to characterize leachate distribution in Laogang landfill, China
    Shi-Jin Feng
    Zhen-Bai Bai
    Ben-Yi Cao
    Shi-Feng Lu
    Shu-Gang Ai
    Environmental Science and Pollution Research, 2017, 24 : 20811 - 20817
  • [5] The use of electrical resistivity tomography and borehole to characterize leachate distribution in Laogang landfill, China
    Feng, Shi-Jin
    Bai, Zhen-Bai
    Cao, Ben-Yi
    Lu, Shi-Feng
    Ai, Shu-Gang
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2017, 24 (25) : 20811 - 20817
  • [6] Evaluation of soil moisture by electrical resistivity in Oxisols of the central Brazilian savanna
    Goulart Ferreira, Quenia de Cassia
    Prado Bacellar, Luis de Almeida
    Moreira Viana, Joao Herbert
    GEODERMA REGIONAL, 2021, 26
  • [7] Analysis of leaks from geomembrane in a sanitary landfill through models of electrical resistivity tomography in South Brazil
    Moreira, Cesar Augusto
    Innocenti Helene, Livia Portes
    Nogara, Paulo
    Ilha, Lenon Melo
    ENVIRONMENTAL EARTH SCIENCES, 2018, 77 (01)
  • [8] Analysis of leaks from geomembrane in a sanitary landfill through models of electrical resistivity tomography in South Brazil
    César Augusto Moreira
    Lívia Portes Innocenti Helene
    Paulo Nogara
    Lenon Melo Ilha
    Environmental Earth Sciences, 2018, 77
  • [9] Characterization of Mined Metals from a Brazilian Sanitary Landfill
    de Godoy Leme, Mariane Alves
    Kakitani, Rafael
    Takeda, Cintia Minori
    Silva, Kennedy Gabriel
    Cheung, Noe
    Miguel, Miriam Goncalves
    JOURNAL OF SUSTAINABLE METALLURGY, 2022, 8 (04) : 1904 - 1914
  • [10] Characterization of Mined Metals from a Brazilian Sanitary Landfill
    Mariane Alves de Godoy Leme
    Rafael Kakitani
    Cintia Minori Takeda
    Kennedy Gabriel Silva
    Noé Cheung
    Miriam Gonçalves Miguel
    Journal of Sustainable Metallurgy, 2022, 8 : 1904 - 1914