Assessment of the abdominal aorta and its visceral branches by contrast-enhanced dynamic volumetric hepatic parallel magnetic resonance imaging: feasibility, reliability and accuracy

被引:0
|
作者
Robert Werder
Daniel Nanz
Amelie M. Lutz
Dominik Weishaupt
Lucas McCormack
Burkhardt Seifert
Borut Marincek
Jürgen K. Willmann
机构
[1] University Hospital Zurich,Institute of Diagnostic Radiology
[2] University Hospital Zurich,Department of Medical Radiology
[3] Stanford University,MIPS, Department of Radiology
[4] University Hospital Zurich,Department of Visceral and Transplantation Surgery
[5] University of Zurich,Department of Biostatistics
来源
European Radiology | 2007年 / 17卷
关键词
Magnetic resonance imaging; Parallel imaging; Three-dimensional spoiled gradient-echo sequence; Liver; Abdominal aorta;
D O I
暂无
中图分类号
学科分类号
摘要
The purpose of this study was to evaluate a new three-dimensional gradient-echo (GRE) MR sequence performed with a parallel acquisition technique to shorten breath-hold times (parallel GRE MRI) in the detection of arterial variants and stenosis of the abdominal aorta and its visceral branches. A total of 102 patients underwent dynamic parallel GRE MRI, timed to the arterial phase by a test bolus (mean breath-hold time, 17 s). For both quantitative and qualitative analysis, the abdominal aorta and its visceral branches were divided into 13 arterial segments. In a subanalysis of 55/102 patients, the accuracy of parallel GRE MRI compared to MDCT in the detection arterial variants and stenosis was calculated for two independent readers. Mean SNRs and CNRs were 47.2 and 35.6, respectively. Image quality was rated good or excellent in 1,234/1,326 segments (93%). Hepatic and renal arterial variants were identified with an accuracy of 93 and 95%, respectively (reader 1) and 98 and 100%, respectively (reader 2). Both readers detected arterial stenosis with an accuracy of 98%. Interobserver agreement was good to excellent for the detection of hepatic (κ=0.69) and renal (κ=0.92) variants and for the diagnosis of stenosis (κ=0.96). Dynamic three-dimensional parallel GRE MRI is feasible and allows a reliable and accurate diagnosis of arterial variants and stenosis of the abdominal aorta and its visceral branches in a short breath-hold-time.
引用
收藏
页码:541 / 551
页数:10
相关论文
共 50 条
  • [1] Assessment of the abdominal aorta and its visceral branches by contrast-enhanced dynamic volumetric hepatic parallel magnetic resonance imaging: feasibility, reliability and accuracy
    Werder, Robert
    Nanz, Daniel
    Lutz, Amelie M.
    Weishaupt, Dominik
    McCormack, Lucas
    Seifert, Burkhardt
    Marincek, Borut
    Willmann, Juergen K.
    EUROPEAN RADIOLOGY, 2007, 17 (02) : 541 - 551
  • [2] Liver transplantation: Dynamic contrast-enhanced magnetic resonance imaging of the hepatic vasculature
    Ward, J
    Spencer, JA
    Guthrie, JA
    Robinson, PJ
    CLINICAL RADIOLOGY, 1996, 51 (03) : 191 - 197
  • [3] Reliability and responsiveness of dynamic contrast-enhanced magnetic resonance imaging in rheumatoid arthritis
    Axelsen, M. B.
    Poggenborg, R. P.
    Stoltenberg, M.
    Kubassova, O.
    Boesen, M.
    Horslev-Petersen, K.
    Bliddal, H.
    Hanson, L. G.
    Ostergaard, M.
    SCANDINAVIAN JOURNAL OF RHEUMATOLOGY, 2013, 42 (02) : 115 - 122
  • [4] Contrast agents in dynamic contrast-enhanced magnetic resonance imaging
    Yan, Yuling
    Sun, Xilin
    Shen, Baozhong
    ONCOTARGET, 2017, 8 (26) : 43491 - 43505
  • [5] Dynamic contrast-enhanced magnetic resonance imaging as an imaging biomarker
    Hylton, Nola
    JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (20) : 3293 - 3298
  • [6] Dynamic contrast-enhanced imaging of the breast with magnetic resonance
    Cron, GO
    Santyr, G
    Kelcz, F
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 1354 - 1356
  • [7] Assessment of the dynamic range in dynamic contrast-enhanced magnetic resonance imaging breast examinations
    Ledger, A. E. W.
    Borri, M.
    Schmidt, M.
    Pope, R.
    Scurr, E.
    Wallace, T.
    Richardson, C.
    Usher, M.
    Allen, S.
    Wilson, R.
    Thomas, K.
    deSouza, N.
    Leach, M. O.
    BREAST CANCER RESEARCH, 2012, 14
  • [8] Assessment of the dynamic range in dynamic contrast-enhanced magnetic resonance imaging breast examinations
    AEW Ledger
    M Borri
    M Schmidt
    R Pope
    E Scurr
    T Wallace
    C Richardson
    M Usher
    S Allen
    R Wilson
    K Thomas
    N deSouza
    MO Leach
    Breast Cancer Research, 14
  • [9] Diagnostic accuracy of subjective kinetic assessment of masses in contrast-enhanced mammography in comparison with contrast-enhanced magnetic resonance imaging
    Prema Subramaniam
    Rupa Renganathan
    P. Suganya
    Adrija Mandal
    Egyptian Journal of Radiology and Nuclear Medicine, 54
  • [10] Diagnostic accuracy of subjective kinetic assessment of masses in contrast-enhanced mammography in comparison with contrast-enhanced magnetic resonance imaging
    Subramaniam, Prema
    Renganathan, Rupa
    Suganya, P.
    Mandal, Adrija
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2023, 54 (01):