Leveraging Blur Information for Plenoptic Camera Calibration

被引:0
|
作者
Mathieu Labussière
Céline Teulière
Frédéric Bernardin
Omar Ait-Aider
机构
[1] Université Clermont Auvergne, Clermont Auvergne INP, CNRS, Institut Pascal
[2] Cerema,undefined
[3] Équipe-Projet STI,undefined
来源
关键词
Plenoptic camera; Calibration; Multi-focus; Relative blur; Blur circle;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents a novel calibration algorithm for plenoptic cameras, especially the multi-focus configuration, where several types of micro-lenses are used, using raw images only. Current calibration methods rely on simplified projection models, use features from reconstructed images, or require separated calibrations for each type of micro-lens. In the multi-focus configuration, the same part of a scene will demonstrate different amounts of blur according to the micro-lens focal length. Usually, only micro-images with the smallest amount of blur are used. In order to exploit all available data, we propose to explicitly model the defocus blur in a new camera model with the help of our newly introduced Blur Aware Plenoptic (BAP) feature. First, it is used in a pre-calibration step that retrieves initial camera parameters, and second, to express a new cost function to be minimized in our single optimization process. Third, it is exploited to calibrate the relative blur between micro-images. It links the geometric blur, i.e., the blur circle, to the physical blur, i.e., the point spread function. Finally, we use the resulting blur profile to characterize the camera’s depth of field. Quantitative evaluations in controlled environment on real-world data demonstrate the effectiveness of our calibrations.
引用
收藏
页码:1655 / 1677
页数:22
相关论文
共 50 条
  • [1] Leveraging Blur Information for Plenoptic Camera Calibration
    Labussiere, Mathieu
    Teuliere, Celine
    Bernardin, Frederic
    Ait-Aider, Omar
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 2022, 130 (07) : 1655 - 1677
  • [2] Blur Aware Calibration of Multi-Focus Plenoptic Camera
    Labussiere, Mathieu
    Teuliere, Celine
    Bernardin, Frederic
    Ait-Aider, Omar
    [J]. 2020 IEEE/CVF CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION (CVPR), 2020, : 2542 - 2551
  • [3] Volumetric calibration of a plenoptic camera
    Hall, Elise Munz
    Fahringer, Timothy W.
    Guildenbecher, Daniel R.
    Thurow, Brian S.
    [J]. APPLIED OPTICS, 2018, 57 (04) : 914 - 923
  • [4] Unfocused plenoptic camera calibration
    Murgia, F.
    Fernandez, S. B.
    Giusto, D. D.
    Perra, C.
    [J]. 2014 22ND TELECOMMUNICATIONS FORUM TELFOR (TELFOR), 2014, : 517 - 520
  • [5] Automatic calibration method for plenoptic camera
    Luan, Yinsen
    He, Xing
    Xu, Bing
    Yang, Ping
    Tang, Guomao
    [J]. OPTICAL ENGINEERING, 2016, 55 (04)
  • [6] Decoding and calibration method on focused plenoptic camera
    Zhang C.
    Ji Z.
    Wang Q.
    [J]. Computational Visual Media, 2016, 2 (1) : 57 - 69
  • [7] Decoding and calibration method on focused plenoptic camera
    Chunping Zhang
    Zhe Ji
    Qing Wang
    [J]. Computational Visual Media, 2016, 2 (01) : 57 - 69
  • [8] Depth estimation and camera calibration of a focused plenoptic camera for visual odometry
    Zeller, Niclas
    Quint, Franz
    Stilla, Uwe
    [J]. ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2016, 118 : 83 - 100
  • [9] New Calibration Method of Plenoptic Camera Using CCD Camera Model
    Kim, Song-Ran
    Jeong, Min-Chang
    Kang, Hyun-Soo
    [J]. 2018 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2018,
  • [10] Plenoptic camera calibration based on microlens distortion modelling
    Darwish, Walid
    Bolsee, Quentin
    Munteanu, Adrian
    [J]. ISPRS JOURNAL OF PHOTOGRAMMETRY AND REMOTE SENSING, 2019, 158 : 146 - 154