Radiation dose in vertebroplasty

被引:0
|
作者
A. Mehdizade
K. O. Lovblad
K. E. Wilhelm
T. Somon
S. G. Wetzel
A. D. Kelekis
H. Yilmaz
G. Abdo
J. B. Martin
J. M. Viera
D. A. Rüfenacht
机构
[1] Geneva University Hospital,Neuroradiology DRRI
来源
Neuroradiology | 2004年 / 46卷
关键词
Vertebroplasty; Radiation dosimetry;
D O I
暂无
中图分类号
学科分类号
摘要
We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator’s lead apron. We found doses of 0.022–3.256 mGy outside and 0.01–0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5–8.5 mGy. This preliminary study indicates greater exposure to the operator’s hands than expected from traditional apron measurements.
引用
收藏
页码:243 / 245
页数:2
相关论文
共 50 条
  • [1] Radiation dose in vertebroplasty
    Mehdizade, A
    Lovblad, KO
    Wilhelm, KE
    Somon, T
    Wetzel, SG
    Kelekis, AD
    Yilmaz, H
    Abdo, G
    Martin, JB
    Viera, JM
    Rüfenacht, DA
    NEURORADIOLOGY, 2004, 46 (03) : 243 - 245
  • [2] Patient radiation dose from vertebroplasty and kyphoplasty
    Miller, DL
    RADIOLOGY, 2005, 234 (03) : 970 - 971
  • [3] Patient radiation dose in percutaneous vertebroplasty.
    Schueler, B
    HEALTH PHYSICS, 2002, 82 (06): : S174 - S174
  • [4] Radiation dose reduction to medical staff during vertebroplasty
    Kruger, R
    Faciszewski, T
    MEDICAL PHYSICS, 2003, 30 (06) : 1399 - 1399
  • [5] Radiation dose reduction to medical staff during vertebroplasty - A review of techniques and methods to mitigate occupational dose
    Kruger, R
    Faciszewski, T
    SPINE, 2003, 28 (14) : 1608 - 1613
  • [6] Vertebroplasty and kyphoplasty: Do fluoroscopy operators know about radiation dose, and should they want to know?
    Seibert, AJ
    RADIOLOGY, 2004, 232 (03) : 633 - 634
  • [7] Dual guidance (CT and fluoroscopy) vertebroplasty: radiation dose to radiologists. How much and where?
    Amoretti, Nicolas
    Lesbats, Virginie
    Marcy, Pierre-Yves
    Hauger, Olivier
    Amoretti, Marie-eve
    Maratos, Yvonne
    Ianessi, Antoine
    Boileau, Pascal
    SKELETAL RADIOLOGY, 2010, 39 (12) : 1229 - 1235
  • [8] Dual guidance (CT and fluoroscopy) vertebroplasty: radiation dose to radiologists. How much and where?
    Nicolas Amoretti
    Virginie Lesbats
    Pierre-Yves Marcy
    Olivier Hauger
    Marie-eve Amoretti
    Yvonne Maratos
    Antoine Ianessi
    Pascal Boileau
    Skeletal Radiology, 2010, 39 : 1229 - 1235
  • [9] Significantly reduced radiation dose to operators during percutaneous vertebroplasty using a new cement delivery device
    Guang-Quan Zhang
    Yan-Zheng Gao
    Shu-Lian Chen
    Shuai Ding
    Kun Gao
    BMC Musculoskeletal Disorders, 15
  • [10] Radiation exposure to operators during vertebroplasty
    Komemushi, A
    Tanigawa, N
    Kariya, S
    Kojima, H
    Shomura, Y
    Sawada, S
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 16 (10) : 1327 - 1332