Non-invasive assessment of central venous pressure in heart failure: a systematic prospective comparison of echocardiography and Swan-Ganz catheter

被引:0
|
作者
Tobias Szymczyk
Odile Sauzet
Lech J. Paluszkiewicz
Angelika Costard-Jäckle
Max Potratz
Volker Rudolph
Jan F. Gummert
Henrik Fox
机构
[1] Herz- und Diabeteszentrum NRW,Clinic for General and Interventional Cardiology/Angiology
[2] Ruhr-Universität Bochum,Epidemiology and International Public Health, Bielefeld School of Public Health and Statistical Consulting Centre
[3] Bielefeld University,Clinic for Thoracic and Cardiovascular Surgery
[4] Herz- und Diabeteszentrum NRW,Heart Failure Department
[5] Ruhr-Universität Bochum,undefined
[6] Herz- und Diabeteszentrum NRW,undefined
[7] Ruhr-Universität Bochum,undefined
关键词
Heart failure; Inferior vena cava; Echocardiography; Central venous pressure; Right-heart catheterization;
D O I
暂无
中图分类号
学科分类号
摘要
Assessing hemodynamics, especially central venous pressure (CVP), is essential in heart failure (HF). Right heart catheterization (RHC) is the gold-standard, but non-invasive methods are also needed. However, the role of 2-dimensional echocardiography (2DE) remains uncertain, and 3-dimensional echocardiography (3DE) is not always available. This study investigated standardized and breathing-corrected assessment of inferior vena cava (IVC) volume using echocardiography (2DE and 3DE) versus CVP determined invasively using RHC. Sixty consecutive HF patients were included (82% male, age 54 ± 11 years, New York Heart Association class 2.23 ± 0.8, ejection fraction 46 ± 18.4%, brain natriuretic peptide 696.93 ± 773.53 pg/mL). All patients underwent Swan-Ganz RHC followed by 2DE and 3DE, and IVC volume assessment. On 2DE, mean IVC size was 18.3 ± 5.5 mm and 13.8 ± 6 mm in the largest deflection and shortest distention, respectively. Mean CVP from RHC was 9.3 ± 5.3 mmHg. Neither 2DE nor 3DE showed acceptable correlation with invasively measured CVP; IVC volume acquisition showed optimal correlation with RHC CVP (0.64; 95% confidence interval 0.46–0.77), with better correlation when mitral valve early diastole E wave and right ventricular end-diastolic diameter were added. Using a CVP cut-point of 10 mmHg, receiver operating characteristic curve showed true positivity (specificity) of 0.90 and sensitivity of 62% for predicting CVP. A validation study confirmed these findings and verified the high predictive value of IVC volume assessment. Neither 2DE nor 3DE alone can reliably mirror CVP, but IVC volume acquisition using echocardiography allows non-invasive and adequate approximation of CVP. Correlation with invasively measured pressure was strongest when CVP is > 10 mmHg.
引用
收藏
页码:1821 / 1829
页数:8
相关论文
共 50 条
  • [1] Non-invasive assessment of central venous pressure in heart failure: a systematic prospective comparison of echocardiography and Swan-Ganz catheter
    Szymczyk, Tobias
    Sauzet, Odile
    Paluszkiewicz, Lech J.
    Costard-Jaeckle, Angelika
    Potratz, Max
    Rudolph, Volker
    Gummert, Jan F.
    Fox, Henrik
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (10): : 1821 - 1829
  • [2] Non-invasive assessment of central venous pressure in heart failure: comparing three-dimensional echocardiography and Swan-Ganz catheter
    Szyrnczyk, T.
    Paluszkiewicz, L. J.
    Costard-Jaeckle, A.
    Rudolph, V.
    Gummert, J. F.
    Fox, H.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1439 - 1439
  • [3] SIMPLE, RAPID METHOD FOR INSERTION OF A SWAN-GANZ CATHETER USING AN EXISTING CENTRAL VENOUS OR SWAN-GANZ CATHETER
    FRIED, DA
    BERK, JL
    AMERICAN JOURNAL OF SURGERY, 1980, 139 (03): : 454 - 455
  • [4] Comparison of a radiofrequency-based wireless pressure sensor to Swan-Ganz catheter and echocardiography for ambulatory assessment of pulmonary artery pressure in heart failure
    Verdejo, Hugo E.
    Castro, Pablo F.
    Concepcion, Roberto
    Ferrada, Marcela A.
    Alfaro, Mario A.
    Alcaino, Milton E.
    Deck, Carlos C.
    Bourge, Robert C.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (25) : 2375 - 2382
  • [5] Difficult removal: a Swan-Ganz catheter coiled on the central venous catheter
    Shen, Jian
    Ma, Luyao
    Huang, He
    JOURNAL OF CARDIOTHORACIC SURGERY, 2020, 15 (01)
  • [6] Difficult removal: a Swan-Ganz catheter coiled on the central venous catheter
    Jian Shen
    Luyao Ma
    He Huang
    Journal of Cardiothoracic Surgery, 15
  • [7] Doppler Echocardiography in Advanced Systolic Heart Failure A Noninvasive Alternative to Swan-Ganz Catheter
    Temporelli, Pier Luigi
    Scapellato, Francesco
    Eleuteri, Ermanno
    Imparato, Alessandro
    Giannuzzi, Pantaleo
    CIRCULATION-HEART FAILURE, 2010, 3 (03) : 387 - 394
  • [8] Radiofrequency based wireless pressure sensor is a reliable method for hemodynamic assessment in ambulatory chronic heart failure patients: Comparison to swan-ganz catheter and echocardiography.
    Castro, Pablo
    Verdejo, Hugo
    Bourge, Robert
    Concepcion, Roberto
    Ferrada, Marcela
    Martinez, Alejandro
    Alcaino, Milton
    Alfaro, Mario
    Godoy, Ivan
    Perrone, Sergio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 48A - 48A
  • [9] True knot in a Swan-Ganz catheter on a central venous catheter: A simple trick for percutaneous removal
    Castella, M
    Riambau, V
    Palacin, J
    Font, C
    Mulet, J
    INTENSIVE CARE MEDICINE, 1996, 22 (08) : 830 - 831
  • [10] Secondary migration of a pre-existing central venous catheter due to a Swan-Ganz catheter insertion
    Cho, Joonho
    Yoo, Byung Hoon
    Park, Jihwan
    Lim, Yun Hee
    Jun, In-jung
    Kim, Kye-min
    ANESTHESIA AND PAIN MEDICINE, 2023, 18 (01):