Comparison of F-18 FDG-PET/CT and Tc-99m MIBI in the preoperative evaluation of cold thyroid nodules in the same patient group

被引:0
|
作者
Sait Sager
Betul Vatankulu
Ezgi Erdogan
Sanem Mut
Serkan Teksoz
Tulin Ozturk
Kerim Sonmezoglu
Bedii Kanmaz
机构
[1] Istanbul University,Department of Nuclear Medicine, Cerrahpasa Medical Faculty
[2] Istanbul University,Department of Endocrine Surgery, Cerrahpasa Medical Faculty
[3] Istanbul University,Department of Pathology, Cerrahpasa Medical Faculty
来源
Endocrine | 2015年 / 50卷
关键词
Thyroid nodule; Scintigraphy; MIBI; FDG-PET/CT;
D O I
暂无
中图分类号
学科分类号
摘要
Recent studies have reported that standardized uptake values of FDG-PET imaging might predict malignant thyroid nodules and can be used in the preoperative evaluation of thyroid lesions. The aim of our study was to evaluate FDG-PET imaging in patients with cold thyroid nodules and to compare the imaging findings with Tc-99m MIBI scans and with post-op histopathology results. Twenty-three patients (18F, 5M) with 24 nodules that were suspicious in ultrasound and cold in Tc-99m pertechnetate scan, were included in the study. Each nodule underwent sonographically guided fine-needle aspiration biopsy. FDG-PET and MIBI scans were performed with an interval of 3–5 days. All patients underwent thyroidectomy and their FDG-PET, and MIBI thyroid scan results were compared with post-thyroidectomy pathology results. Post-op histopathology results found 7 malignant and 17 benign nodules. Six of the seven malignant nodules had increased uptake, which were positive for malignancy in both PET and MIBI scans. Each imaging method used different radiopharmaceuticals but showed one false-negative result in two different patients. FDG-PET produced false positives in eight nodules and MIBI scans found false positives in four nodules. FDG-PET imaging and MIBI scan showed the same sensitivity in malignant nodule evaluation, but their specificity differed. As a result, we suggest that FDG-PET imaging is not superior to MIBI scanning in differentiating malignant from benign thyroid nodules. MIBI imaging should be the first choice in the preoperative evaluation of patients with cold thyroid nodules as an adjunct procedure to FNAB because of its low cost and availability. This imaging technique can be used routinely in patients who are reluctant to undergo FNAB.
引用
收藏
页码:138 / 145
页数:7
相关论文
共 50 条
  • [1] Comparison of F-18 FDG-PET/CT and Tc-99m MIBI in the preoperative evaluation of cold thyroid nodules in the same patient group
    Sager, Sait
    Vatankulu, Betul
    Erdogan, Ezgi
    Mut, Sanem
    Teksoz, Serkan
    Ozturk, Tulin
    Sonmezoglu, Kerim
    Kanmaz, Bedii
    ENDOCRINE, 2015, 50 (01) : 138 - 145
  • [2] Comparison of F-18 FDG PET/CT and Tc-99m-MIBI in the Evaluation of Cold Thyroid Nodules.
    Kanmaz, B.
    Erdogan, E. B.
    Mut, S. S.
    Kabasakal, L.
    Halac, M.
    Sayman, H. B.
    Aksoy, F.
    Sonmezoglu, K.
    Onsel, C.
    Uslu, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S220 - S221
  • [3] Comparison of Tc-99m MIBI and F-18 FDG PET/CT in Patients with Multiple Myeloma: Preliminary Results
    Boz, A.
    Talay, B.
    Salim, O.
    Karadogan, I.
    Undar, L.
    Yildiz, A.
    Aydin, F.
    Gungor, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S357 - S357
  • [4] Comparison of Tc-99m Sestamibi and F-18 FDG-PET in the Assessment of Multiple Myeloma
    Lin, W. Y.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S152 - S152
  • [5] The Comparison Of F-18 FDG PET/BT VE Tc-99m MIBI SPECT/BT In Multiple Myeloma
    Khosroshahi, S. Razavi
    Sayman, H.
    Berk, S.
    Balkanay, O.
    Nematyazar, J.
    Vatankulu, B.
    Sager, S.
    Halac, M.
    Demir, M.
    Kabasakal, L.
    Uslu, I.
    Sonmezoglu, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S319 - S319
  • [6] Preoperative evaluation of thyroid nodules with 18FDG-PET/CT or MIBI scan?
    Hurtado-Lopez, Luis Mauricio
    Martinez-Duncker, Carlos
    SURGERY, 2007, 141 (01) : 121 - 121
  • [7] Myocardial viability assessment with gated SPECT Tc-99m tetrofosmin % wall thickening: Comparison with F-18 FDG-PET
    Atsushi Maruyama
    Shinji Hasegawa
    Asit Kr. Paul
    Mu Xiuli
    Jun Yoshioka
    Kaoru Maruyama
    Masatsugu Hori
    Tsunehiko Nishimura
    Annals of Nuclear Medicine, 2002, 16 : 25 - 32
  • [8] COMPARISON OF TC-99M SESTAMIBI SPECT AND FDG-PET IN THE EVALUATION OF SARCOMAS
    PODOLOFF, DA
    KIM, EE
    HAYNIE, TP
    BHADKAMKAR, VA
    BENJAMIN, RS
    KORKMAZ, M
    RADIOLOGY, 1992, 185 : 262 - 262
  • [9] Tc-99m MIBI scintigraphy in patients with lung cancer comparison with CT and fluorine-18 FDG PET imaging
    Wang, H
    Maurea, S
    Mainolfi, C
    Fiore, F
    Gravina, A
    Panico, MR
    Bazzicalupo, L
    Salvatore, M
    CLINICAL NUCLEAR MEDICINE, 1997, 22 (04) : 243 - 249
  • [10] Incidental uptake of tracer in the thyroid on F-18 FDG-PET/CT
    Agrawal, Kanhaiyalal
    Ul-Hassan, Fahim
    Simo, Ricard
    Carroll, Paul
    Mohan, Hosahalli
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55