Voltammetric myoglobin sensor based on a glassy carbon electrode modified with a composite film consisting of carbon nanotubes and a molecularly imprinted polymerized ionic liquid

被引:0
|
作者
Yanying Wang
Miao Han
Xiaoxue Ye
Kangbing Wu
Tsunghsueh Wu
Chunya Li
机构
[1] South-Central University for Nationalities,Key Laboratory of Analytical Chemistry of the State Ethnic Affairs Commission, College of Chemistry and Materials Science
[2] Huazhong University of Science and Technology,Key Laboratory for Material Chemistry of Energy Conversion and Storage, Ministry of Education, School of Chemistry and Chemical Engineering
[3] University of Wisconsin-Platteville,Department of Chemistry
来源
Microchimica Acta | 2017年 / 184卷
关键词
Molecularly imprinted polymer; Polymerized ionic liquid; Multi-walled carbon nanotubes; Electrochemical assay; Myoglobin analysis;
D O I
暂无
中图分类号
学科分类号
摘要
The ionic liquid 1-{3-[(2-aminoethyl)amino]propyl}-3-vinylimidazole bromide was synthesized and used to fabricate a molecularly imprinted film for electrochemical sensing of myoglobin (Myo). This film was deposited on a glassy carbon electrode modified with multi-walled carbon nanotubes by using the ionic liquid as the functional monomer, Myo as the template, N,N′-methylenebisacrylamide as the crosslinker, and a redox system containing ammonium persulfate and N,N,N′,N′-tetramethylethylenediamine as the initiator. The sensing performance of the modified electrode was investigated by using the hexacyanoferrate system as an electrochemical redox probe. The results demonstrated that the sensor possesses good selectivity and high sensitivity. The oxidation peak current at the potential of ~0.3 V (vs. SCE) was found linearly related to the myoglobin concentration in the range from 60.0 nM to 6.0 μM, with a 9.7 nM detection limit at an S/N ratio of 3. The sensor was applied to the determination of Myo in spiked serum samples where it showed average recoveries (for n = 5) of 96.5 %.
引用
收藏
页码:195 / 202
页数:7
相关论文
共 50 条
  • [1] Voltammetric myoglobin sensor based on a glassy carbon electrode modified with a composite film consisting of carbon nanotubes and a molecularly imprinted polymerized ionic liquid
    Wang, Yanying
    Han, Miao
    Ye, Xiaoxue
    Wu, Kangbing
    Wu, Tsunghsueh
    Li, Chunya
    [J]. MICROCHIMICA ACTA, 2017, 184 (01) : 195 - 202
  • [2] Gliclazide voltammetric sensor based on electropolymerized molecularly imprinted polypyrrole film onto glassy carbon electrode
    Hrichi, Hajer
    Louhaichi, Mohamed Radhouan
    Monser, Lotfi
    Adhoum, Nafaa
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2014, 204 : 42 - 49
  • [3] Voltammetric Determination of Flunixin on Molecularly Imprinted Polypyrrole Modified Glassy Carbon Electrode
    Radi, Abd-Elgawad
    Abd El-Ghany, Nadia
    Wahdan, Tarek
    [J]. JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2016, 2016
  • [4] Electrochemical Sensor for Trichloroacetic Acid with Chitosan/Ionic Liquid/Myoglobin Composite Film Modified Carbon Ionic Liquid Electrode
    Wang, Yan
    Wu, Jie
    Zhan, Tianrong
    Sun, Wei
    Jiao, Kui
    [J]. SENSOR LETTERS, 2009, 7 (06) : 1106 - 1112
  • [5] A Salbutamol Sensor Based on Carbon Nanotubes Modified Electrode and Molecularly Imprinted Polymers
    Qi Yu-Bing
    Liu Ying
    Song Qi-Jun
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (07) : 1053 - 1057
  • [6] Impedance sensing platform for 4,4-dibromobiphenyl based on a molecularly imprinted polymerized ionic liquid film/gold nanoparticle-modified glassy carbon electrode
    Wei, Qiuxi
    Wu, Kangbing
    Wang, Zhengguo
    Ye, Xiaoxue
    Li, Chunya
    Wang, Yanying
    Gan, Tian
    [J]. JOURNAL OF NANOPARTICLE RESEARCH, 2018, 20 (11)
  • [7] Impedance sensing platform for 4,4′-dibromobiphenyl based on a molecularly imprinted polymerized ionic liquid film/gold nanoparticle-modified glassy carbon electrode
    Qiuxi Wei
    Kangbing Wu
    Zhengguo Wang
    Xiaoxue Ye
    Chunya Li
    Yanying Wang
    Tian Gan
    [J]. Journal of Nanoparticle Research, 2018, 20
  • [8] A highly selective and sensitive voltammetric sensor with molecularly imprinted polymer based silver@gold nanoparticles/ionic liquid modified glassy carbon electrode for determination of ceftizoxime
    Beytur, Murat
    Kardas, Faruk
    Akyildirim, Onur
    Ozkan, Abdullah
    Bankoglu, Bahar
    Yuksek, Haydar
    Yola, Mehmet Lutfi
    Atar, Necip
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2018, 251 : 212 - 217
  • [9] Voltammetric lidocaine sensor by using a glassy carbon electrode modified with porous carbon prepared from a MOF, and with a molecularly imprinted polymer
    Junjie Zhang
    Jiang Liu
    Yang Zhang
    Feng Yu
    Fu Wang
    Zhengchun Peng
    Yingchun Li
    [J]. Microchimica Acta, 2018, 185
  • [10] Voltammetric lidocaine sensor by using a glassy carbon electrode modified with porous carbon prepared from a MOF, and with a molecularly imprinted polymer
    Zhang, Junjie
    Liu, Jiang
    Zhang, Yang
    Yu, Feng
    Wang, Fu
    Peng, Zhengchun
    Li, Yingchun
    [J]. MICROCHIMICA ACTA, 2018, 185 (01)