An automated microfluidic system with one-dimensional beads array for multiplexed torch detection at point-of-care testing

被引:0
|
作者
Hao Li
Shengda Yu
Dong Wang
Xinying Huang
Qiang Fu
Donglin Xu
Lulu Zhang
Shizhi Qian
Xianbo Qiu
机构
[1] Beijing University of Chemical Technology,Institute of Microfluidic Chip Development in Biomedical Engineering, College of Information Science and Technology
[2] Beijing Wantai Biological Pharmacy Enterprise Co.,Institute of Micro/Nanotechnology
[3] Ltd,undefined
[4] Old Dominion University,undefined
来源
Biomedical Microdevices | 2022年 / 24卷
关键词
Microfluidic chip; Beads array; Multiplexed detection; TORCH; Chemiluminescence; Point-of-care testing (POCT);
D O I
暂无
中图分类号
学科分类号
摘要
An automated microfluidic system with functionalized beads has been developed for multiplexed TORCH detection at point-of-care testing. A concise microfluidic chip consisting of a one-dimensional beads array is developed to simultaneously detect TOX, RUB, CMV, HSV-I and HSV-II respectively with five functionalized beads. A compact liquid handling module has been developed to automate the sandwiched chemiluminescence immunoassay within the one-dimensional beads array of the microfluidic chip. A precise ram pump is adopted to not only add reagent into the microfluidic chip from outside, but also facilitate elaborate fluid control inside the microfluidic chip for improved performance. A large-size waste chamber with a liquid-absorbing sponge holds the waste reagent within the microfluidic chip to prevent backflow. The one-dimensional beads array is heated from double-sides at 37 ℃ for sensitive detection with reduced time. A sensitive CMOS camera is adopted to take chemiluminescence image from the one-dimensional beads array, and a custom processing algorithm is adopted to analyze the image. For each serum sample, five different infections can be simultaneously detected with the automated microfluidic system. Experimental results show that efficient, sensitive, and accurate multiplexed TORCH detection can be conveniently achieved with the integrated microfluidic system.
引用
收藏
相关论文
共 50 条
  • [1] An automated microfluidic system with one-dimensional beads array for multiplexed torch detection at point-of-care testing
    Li, Hao
    Yu, Shengda
    Wang, Dong
    Huang, Xinying
    Fu, Qiang
    Xu, Donglin
    Zhang, Lulu
    Qian, Shizhi
    Qiu, Xianbo
    BIOMEDICAL MICRODEVICES, 2022, 24 (04)
  • [2] A bead-based microfluidic system for joint detection in TORCH screening at point-of-care testing
    Qiu, Xianbo
    Zhang, Junhui
    Li, Yichen
    Zhang, Chaomin
    Wang, Dong
    Zhu, Weiling
    Li, Fang
    Ge, Shengxiang
    Xia, Ningshao
    Qian, Shizhi
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2018, 24 (04): : 2007 - 2015
  • [3] A bead-based microfluidic system for joint detection in TORCH screening at point-of-care testing
    Xianbo Qiu
    Junhui Zhang
    Yichen Li
    Chaomin Zhang
    Dong Wang
    Weiling Zhu
    Fang Li
    Shengxiang Ge
    Ningshao Xia
    Shizhi Qian
    Microsystem Technologies, 2018, 24 : 2007 - 2015
  • [4] One-dimensional microfluidic beads array for multiple mRNAs expression detection
    Wen, Jianhui
    Yang, Xiaohai
    Wang, Kemin
    Tan, Weihong
    Zhou, Leiji
    Zuo, Xinbing
    Zhang, He
    Chen, Yunqing
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2759 - 2762
  • [5] Microfluidic point-of-care testing device for multiplexed detection of liver function blood markers
    Li, Yingchun
    Cheng, Haobo
    BIOMEDICAL OPTICS EXPRESS, 2024, 15 (10): : 5803 - 5817
  • [6] Fully Integrated and High-Throughput Microfluidic System for Multiplexed Point-Of-Care Testing
    Li, Shunji
    Zhang, Ying
    Liu, Jingxuan
    Wang, Xing
    Qian, Chungen
    Wang, Jingjing
    Wu, Liqiang
    Dai, Chenxi
    Yuan, Huijuan
    Wan, Chao
    Li, Jiashuo
    Du, Wei
    Feng, Xiaojun
    Li, Yiwei
    Chen, Peng
    Liu, Bi-Feng
    SMALL, 2024, 20 (43)
  • [7] An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
    Teixeira, William
    Pallas-Tamarit, Yeray
    Juste-Dolz, Augusto
    Sena-Torralba, Amadeo
    Gozalbo-Rovira, Roberto
    Rodriguez-Diaz, Jesus
    Navarro, David
    Carrascosa, Javier
    Gimenez-Romero, David
    Maquieira, Angel
    Morais, Sergi
    BIOSENSORS & BIOELECTRONICS, 2022, 213
  • [8] An all-in-one point-of-care testing device for multiplexed detection of respiratory infections
    Teixeira, William
    Pallas-Tamarit, Yeray
    Juste-Dolz, Augusto
    Sena-Torralba, Amadeo
    Gozalbo-Rovira, Roberto
    Rodriguez-Diaz, Jesus
    Navarro, David
    Carrascosa, Javier
    Gimenez-Romero, David
    Maquieira, Angel
    Morais, Sergi
    BIOSENSORS & BIOELECTRONICS, 2022, 213
  • [9] Nucleic acids detection using cationic fluorescent polymer based on one-dimensional microfluidic beads array
    Yang, Xiaohai
    Zhao, Xiang
    Zuo, Xinbing
    Wang, Kemin
    Wen, Jianhui
    Zhang, He
    TALANTA, 2009, 77 (03) : 1027 - 1031
  • [10] Fully integrated and automated centrifugal microfluidic chip for point-of-care multiplexed molecular diagnostics
    Xiao, Yujin
    Zhou, Mengfan
    Liu, Changgen
    Gao, Siyu
    Wan, Chao
    Li, Shunji
    Dai, Chenxi
    Du, Wei
    Feng, Xiaojun
    Li, Yiwei
    Chen, Peng
    Liu, Bi-Feng
    BIOSENSORS & BIOELECTRONICS, 2024, 255