Thermal lens spectrometry under excitation of a divergent pump beam

被引:0
|
作者
Mingqiang Liu
Mladen Franko
机构
[1] University of Nova Gorica,Laboratory for Environmental Research
来源
Applied Physics B | 2014年 / 115卷
关键词
Probe Beam; Pump Beam; Sample Length; Thermal Lens; Beam Waist;
D O I
暂无
中图分类号
学科分类号
摘要
Thermal lens spectrometry (TLS) under excitation of a divergent pump beam is discussed in both conventional and microscopic TLS instruments. A refined thermal lens (TL) model was proposed for calculating the TL signal of a “finite TL element.” Experiments as well as comparison with numerical simulations demonstrated that the effective sample length for a certain pump beam profile was about six times the confocal distance of the pump beam for laser-excited case and 1.5 mm for incoherent light source-excited case. For laser-excited conventional TLS instrument or thermal lens microscope (TLM), an empirical formula of the optimum pump beam waist radius for maximum detection sensitivity was obtained at a given sample length. At larger pump beam waist radius of 7 μm, the TL signal was found 2.5 times lower compared to the diffraction limit; however, the resulting two orders of magnitude lower power density in the sample could be quite desirable for the detection of photolabile analytes. By investigating the influence of a finite TL element on the TL signal, we found that an optimal distance between the probe beam waist and the sample was needed to assure the maximum detection sensitivity and good response linearity. Under the optimal detection scheme, limit of detection of the laser-excited TLM at 4 mW power was evaluated to be 8.6 × 10−9 M for 100-μm-thick ferroin solution, corresponding to an absorbance of 9.5 × 10−7 absorbance units.
引用
收藏
页码:269 / 277
页数:8
相关论文
共 50 条
  • [1] Thermal lens spectrometry under excitation of a divergent pump beam
    Liu, Mingqiang
    Franko, Mladen
    APPLIED PHYSICS B-LASERS AND OPTICS, 2014, 115 (02): : 269 - 277
  • [2] DOUBLE-BEAM THERMAL LENS SPECTROMETRY
    JANSEN, KL
    HARRIS, JM
    ANALYTICAL CHEMISTRY, 1985, 57 (13) : 2434 - 2436
  • [3] ROTOREFLECTED LASER-BEAM THERMAL LENS SPECTROMETRY
    YEN, Y
    ANALYTICAL CHEMISTRY, 1986, 58 (07) : 1420 - 1424
  • [4] Pulsed-laser crossed-beam thermal lens spectrometry for detection in a microchannel: Influence of the size of the excitation beam waist
    Ghaleb, KA
    Georges, J
    APPLIED SPECTROSCOPY, 2004, 58 (09) : 1116 - 1121
  • [5] COMPARISON OF SINGLE-BEAM AND DUAL-BEAM CONFIGURATIONS FOR THERMAL LENS SPECTROMETRY
    CARTER, CA
    HARRIS, JM
    ANALYTICAL CHEMISTRY, 1983, 55 (08) : 1256 - 1261
  • [6] THERMAL LENS SPECTROMETRY
    SNOOK, RD
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1990, 333 (1628): : 165 - 166
  • [7] Monitoring supercritical fluid extraction by thermal lens spectrometry with pulsed laser excitation
    Amador-Hernández, J
    Fernández-Romero, JM
    Ramis-Ramos, G
    de Castro, MDL
    ANALYTICA CHIMICA ACTA, 1999, 390 (1-3) : 163 - 173
  • [8] INFLUENCE OF THE OPERATING MODE OF THE EXCITATION LASER IN THERMAL LENS SPECTROMETRY OF ERYTHROSINE IN WATER
    ECKER, A
    GEORGES, J
    MERMET, JM
    APPLIED SPECTROSCOPY, 1992, 46 (04) : 577 - 580
  • [9] SINGLE LASER, SINGLE BEAM PUMP PROBE THERMAL LENS DETECTION IN HPLC
    BOBBITT, DR
    ERSKINE, SR
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 194 : 81 - ANYL
  • [10] A multi-thermal-lens approach to evaluation of multi-pass probe beam configuration in thermal lens spectrometry
    Cabrera, Humberto
    Goljat, Leja
    Korte, Dorota
    Marin, Ernesto
    Franko, Mladen
    ANALYTICA CHIMICA ACTA, 2020, 1100 : 182 - 190