High Shear Thrombus Formation under Pulsatile and Steady Flow

被引:0
|
作者
Lauren D. C. Casa
David N. Ku
机构
[1] Georgia Institute of Technology,George W. Woodruff School of Mechanical Engineering
关键词
Thrombosis; Platelets; Pulsatility; Hemodynamics;
D O I
暂无
中图分类号
学科分类号
摘要
Most previous studies have investigated in vitro thrombus formation under steady flow conditions at physiological shear rates, though occlusive thrombosis leading to myocardial infarction and stroke forms under elevated shear rates and pulsatile flow. Two reports of pulsatile flow on thrombosis have yielded conflicting results. In the present study, we quantify the effect of very high shear, reversing pulsatile flow relevant to coronary thrombosis on platelet deposition leading to occlusive thrombus formation. Whole porcine blood was perfused in a collagen-coated, tubular, stenotic test section under pulsatile or steady flow. Pulsatile flow was generated with a frequency of 60 beats per minute and large magnitude excursions similar to a coronary artery waveform. Alternatively, steady flow conditions from a pressure driven system created shear rates matched to the maximum (16000 s−1), mean (3800 s−1), and an intermediate (6500 s−1) shear rates corresponding to the pulsatile system. Thrombus growth in thickness was recorded using a high-resolution CCD attached to a microscope. Steady flow recreated pulsatile flow thrombus formation in most cases. Lag time, tlag, thrombus growth rate, dV/dt, and time to occlusion, tocc, did not show statistically significant differences between pulsatile flow and steady flow with matched mean shear rate. Pulsatile flow conditions yielded tocc = 5.5 ± 2.8 min, which was not significantly different compared to a steady mean shear rate condition with tocc = 6.2 ± 1.7 min. Similarly, occlusion times for steady intermediate and steady maximum shear rate conditions were not significantly difference from pulsatile flow conditions yielding tocc of 4.6 ± 2.9 and 4.6 ± 1.8 min, respectively. In contrast, lag time for steady flow at maximum shear rate of 16000 s−1 was decreased to 26.1 s compared to pulsatile flow (tlag = 42.7 s, p = 0.03), steady mean flow (tlag = 60.9 s, p = 0.02), and steady intermediate flow (tlag = 39.9 s, p = 0.01). Occlusive thrombus formation under high shear, pulsatile conditions may be modeled in vitro using steady flow with matched mean shear rate with respect to occlusion time, lag time, and growth rate. Our results indicate that the magnitude of shear rate more strongly affects thrombus growth characteristics than flow pulsatility for an arterial frequency.
引用
收藏
页码:154 / 163
页数:9
相关论文
共 50 条
  • [1] High Shear Thrombus Formation under Pulsatile and Steady Flow
    Casa, Lauren D. C.
    Ku, David N.
    [J]. CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2014, 5 (02) : 154 - 163
  • [2] The effect of pulsatile shear flow on thrombus formation and hemolysis
    Hashimoto, S
    Manabe, S
    Matsumoto, Y
    Ikegami, K
    Tsuji, H
    Nakamura, T
    Murashige, Y
    Yamanaka, A
    Sakaue, K
    Kawamasa, T
    Kaku, S
    Otani, H
    Imamura, H
    [J]. PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2461 - 2462
  • [3] Scaling laws for wall shear stress through stenoses under steady and pulsatile flow conditions
    Chua, LP
    Yu, SCM
    Xue, Q
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2001, 215 (H5) : 503 - 514
  • [4] Effect of segmented polyurethane coating on thrombus regulated with pulsatile shear flow
    Hashimoto, S
    Murashige, Y
    Yamanaka, A
    Otani, H
    Imamura, H
    Fukutome, A
    [J]. PROCEEDINGS OF THE 23RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: BUILDING NEW BRIDGES AT THE FRONTIERS OF ENGINEERING AND MEDICINE, 2001, 23 : 492 - 495
  • [5] Thrombus Formation at High Shear Rates
    Casa, Lauren D. C.
    Ku, David N.
    [J]. ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, VOL 19, 2017, 19 : 415 - 433
  • [6] Quantitative imaging of thrombus formation under shear
    Baker, S.
    Phillips, K. G.
    Leung, P. Y.
    Tucker, I
    Gruber, A.
    McCarty, O. J. T.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 227 - 227
  • [7] Microemulsions under steady shear flow
    Komura, S
    Kodama, H
    [J]. FORMATION AND DYNAMICS OF SELF-ORGANIZED STRUCTURES IN SURFACTANTS AND POLYMER SOLUTIONS, 1997, 106 : 75 - 78
  • [8] Emicizumab Augments Thrombus Formation in Whole Blood from Patients with Hemophilia A under High Shear Flow Conditions
    Yaoi, Hiroaki
    Shida, Yasuaki
    Kitazawa, Takehisa
    Shima, Midori
    Nogami, Keiji
    [J]. THROMBOSIS AND HAEMOSTASIS, 2021, 121 (03) : 279 - 286
  • [9] Crystallization kinetics of polypropylene under high pressure and steady shear flow
    Watanabe, K
    Suzuki, T
    Masubuchi, Y
    Taniguchi, T
    Takimoto, J
    Koyama, K
    [J]. POLYMER, 2003, 44 (19) : 5843 - 5849
  • [10] Reduced effect of aspirin on thrombus formation at high shear and disturbed laminar blood flow
    Barstad, RM
    Orvim, U
    Hamers, MJAG
    Tjonnfjord, GE
    Brosstad, FR
    Sakariassen, KS