Seismic fragility of base-isolated water storage tanks under non-stationary earthquakes

被引:0
|
作者
Sandip Kumar Saha
Vasant A. Matsagar
Arvind K. Jain
机构
[1] Indian Institute of Technology (IIT) Delhi,Department of Civil Engineering
来源
关键词
Base-isolated; Earthquake; Fragility; Isolation; Lead-rubber bearing; Monte Carlo simulation; Tank; Uncertainty;
D O I
暂无
中图分类号
学科分类号
摘要
Seismic fragility curves for fixed-base and base-isolated liquid storage tanks are developed under non-stationary earthquakes, and their seismic performance are compared. The correlation between different earthquake intensity measure (IM) parameters and peak response quantities of the base-isolated liquid storage tanks are investigated. The failure criteria are chosen based on (1) the elastic buckling strength of the tank wall, which is defined in terms of critical base shear and critical overturning moment, and (2) in terms of the critical isolation displacement. The uncertainty involved is considered in the earthquake characteristics. Non-stationary earthquake ground motions are generated using Monte Carlo (MC) simulation. Influence of the isolator characteristic parameters and modeling approaches on the seismic fragility of the base-isolated liquid storage tanks is also investigated. Peak ground acceleration is found to be the well correlated IM parameter with the peak response quantities of the base-isolated liquid storage tanks. Substantial decrease in the seismic fragility of the base-isolated liquid storage tanks is observed as compared to the fixed-base tanks. Significant influence of the isolator characteristic parameters on the seismic fragility of the base-isolated liquid storage tanks are reported in the present study.
引用
收藏
页码:1153 / 1175
页数:22
相关论文
共 50 条
  • [1] Seismic fragility of base-isolated water storage tanks under non-stationary earthquakes
    Saha, Sandip Kumar
    Matsagar, Vasant A.
    Jain, Arvind K.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2016, 14 (04) : 1153 - 1175
  • [2] Seismic Fragility Assessment of Base-Isolated Steel Water Storage Tank
    Zhao, Zhuo
    Lu, Xiaowei
    Guo, Yu
    Zhao, Xiaofeng
    SHOCK AND VIBRATION, 2020, 2020
  • [3] Seismic response of base-isolated liquid storage tanks
    Shrimali, MK
    Jangid, RS
    JOURNAL OF VIBRATION AND CONTROL, 2003, 9 (10) : 1201 - 1218
  • [4] Seismic analysis of base-isolated liquid storage tanks
    Shrimali, MK
    Jangid, RS
    JOURNAL OF SOUND AND VIBRATION, 2004, 275 (1-2) : 59 - 75
  • [5] Seismic design of base-isolated LNG-storage-tanks
    Baumann, Thomas
    Bohler, Joachim
    Structural Engineering International: Journal of the International Association for Bridge and Structural Engineering (IABSE), 2001, 11 (02): : 139 - 144
  • [6] Uncertainty quantification and seismic fragility of base-isolated liquid storage tanks using response surface models
    Saha, Sandip Kumar
    Matsagar, Vasant
    Chakraborty, Subrata
    PROBABILISTIC ENGINEERING MECHANICS, 2016, 43 : 20 - 35
  • [7] Non-stationary seismic response analysis of base-isolated buildings with many hysteretic devices
    Ma, C. F.
    Zhang, Y. H.
    Tan, P.
    Kennedy, D.
    Williams, F. W.
    Zhou, F. L.
    COMPUTERS & STRUCTURES, 2013, 123 : 39 - 47
  • [8] Seismic analysis of base-isolated liquid storage tanks on the layered ground
    Kim, MK
    Lim, YM
    Cho, SY
    Lee, K
    PROCEEDINGS OF US-KOREA WORKSHOP ON NEW FRONTIER IN INFRASTRUCTURAL/SEISMIC ENGINEERING, 2000, : 259 - 272
  • [9] PSEUDODYNAMIC TEST FOR EVALUATION OF SEISMIC PERFORMANCE OF BASE-ISOLATED LIQUID STORAGE TANKS
    KIM, NS
    LEE, DG
    ENGINEERING STRUCTURES, 1995, 17 (03) : 198 - 208
  • [10] Response of base-isolated liquid storage tanks
    Jadhav, MB