A double-layer tracheal tube cuff designed to prevent leakage: a bench-top study

被引:0
|
作者
Alberto Zanella
Massimo Cressoni
Myra Epp
Mario Stylianou
Theodor Kolobow
机构
[1] National Institutes of Health,Pulmonary and Critical Care Medicine Branch, NHLBI
[2] National Institutes of Health,Office of Biostatistics Research, OD, NHLBI
来源
Intensive Care Medicine | 2008年 / 34卷
关键词
Tube, endotracheal; Cuff; Leakage, fluid; Aspiration; Ventilator-associated pneumonia;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1145 / 1149
页数:4
相关论文
共 24 条
  • [1] A double-layer tracheal tube cuff designed to prevent leakage: a bench-top study
    Zanella, Alberto
    Cressoni, Massimo
    Epp, Myra
    Stylianou, Mario
    Kolobow, Theodor
    INTENSIVE CARE MEDICINE, 2008, 34 (06) : 1145 - 1149
  • [2] Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: a bench-top study
    Zanella, Alberto
    Scaravilli, Vittorio
    Isgro, Stefano
    Milan, Manuela
    Cressoni, Massimo
    Patroniti, Nicolo
    Fumagalli, Roberto
    Pesenti, Antonio
    INTENSIVE CARE MEDICINE, 2011, 37 (02) : 343 - 347
  • [3] FLUID LEAKAGE ACROSS TRACHEAL TUBE CUFF, EFFECT OF DIFFERENT CUFF MATERIAL, SHAPE AND POSITIVE EXPIRATORY PRESSURE: A BENCH-TOP STUDY
    Zanella, A.
    Scaravilli, V.
    Isgro, S.
    Milan, M.
    Giani, M.
    Patroniti, N.
    Fumagalli, R.
    Pesenti, A.
    INTENSIVE CARE MEDICINE, 2010, 36 : S233 - S233
  • [4] Fluid leakage across tracheal tube cuff, effect of different cuff material, shape, and positive expiratory pressure: a bench-top study
    Alberto Zanella
    Vittorio Scaravilli
    Stefano Isgrò
    Manuela Milan
    Massimo Cressoni
    Nicolò Patroniti
    Roberto Fumagalli
    Antonio Pesenti
    Intensive Care Medicine, 2011, 37 : 343 - 347
  • [5] Evaluation of a new design of tracheal tube cuff to prevent leakage of fluid to the lungs
    Young, PJ
    Ridley, SA
    Downward, G
    BRITISH JOURNAL OF ANAESTHESIA, 1998, 80 (06) : 796 - 799
  • [6] The pressure exerted on the tracheal wall by two endotracheal tube cuffs: A prospective observational bench-top, clinical and radiological study
    Alex Doyle
    Ramai Santhirapala
    Martin Crowe
    Mark Blunt
    Peter Young
    BMC Anesthesiology, 10
  • [7] The pressure exerted on the tracheal wall by two endotracheal tube cuffs: A prospective observational bench-top, clinical and radiological study
    Doyle, Alex
    Santhirapala, Ramai
    Crowe, Martin
    Blunt, Mark
    Young, Peter
    BMC ANESTHESIOLOGY, 2010, 10
  • [8] Effect of tracheal tube cuff shape on fluid leakage across the cuff: an in vitro study
    Dave, M. H.
    Frotzler, A.
    Spielmann, N.
    Madjdpour, C.
    Weiss, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2010, 105 (04) : 538 - 543
  • [9] Method to prevent damage to the tracheal cuff of a double-lumen endotracheal tube during laryngoscopy
    Marymont, J
    Szokol, J
    Fry, W
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1999, 13 (03) : 371 - 371
  • [10] FLUID LEAKAGE PAST TRACHEAL TUBE CUFF: EFFECT OF SUCTIONING MANOEUVRE. A CLINICAL STUDY
    Beuret, P.
    Philippon, B.
    Minacori, F.
    Fabre, X.
    Kaaki, M.
    Carton, M-J
    INTENSIVE CARE MEDICINE, 2011, 37 : S79 - S79