Differentiation of regioisomeric fluoroamphetamine analogs by gas chromatography–mass spectrometry and liquid chromatography–tandem mass spectrometry

被引:0
|
作者
Yukiko Nakazono
Kenji Tsujikawa
Kenji Kuwayama
Tatsuyuki Kanamori
Yuko T. Iwata
Kazuna Miyamoto
Fumiyo Kasuya
Hiroyuki Inoue
机构
[1] National Research Institute of Police Science,Biochemical Toxicology Laboratory, Faculty of Pharmaceutical Sciences
[2] Kobegakuin University,undefined
[3] Hitec,undefined
[4] Inc.,undefined
来源
Forensic Toxicology | 2013年 / 31卷
关键词
Fluoroamphetamine analogs; Regioisomer; Designer drug; GC–MS; LC–MS;
D O I
暂无
中图分类号
学科分类号
摘要
In recent years, a large number of clandestinely produced controlled-substance analogs (designer drugs) of amphetamine with high structural variety have been detected in forensic samples. Analytical differentiation of regioisomers is a significant issue in forensic drug analysis because, in most cases, legal controls are placed only on one or two of the three isomers. In this study, we used gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–tandem mass spectrometry (LC–MS/MS) for the differentiation of regioisomers of fluoroamphetamine analogs (fluoroamphetamines and fluoromethamphetamines), which were synthesized in our laboratories. Free bases and their acylated and silylated derivatives were subjected to GC–MS analysis using DB-1ms, DB-5ms, and DB-17ms capillary columns. The separation of free bases was incomplete on all columns. Trifluoroacetyl derivatives of 3- and 4-positional isomers showed slight separation on DB-1ms and DB-5ms. On the other hand, trimethylsilyl derivatization enabled baseline separation of six fluoroamphetamine analogs on DB-1ms and DB-5ms columns, which was sufficient for unequivocal identification. For LC–MS/MS, a pentafluorophenyl column was able to separate six regioisomeric fluoroamphetamine analogs but a conventional C18 column could not achieve separation between 3- and 4-positional isomers. These results show that a suitable choice of derivatization and analytical columns allows the differentiation of regioisomeric fluoroamphetamine analogs.
引用
收藏
页码:241 / 250
页数:9
相关论文
共 50 条
  • [1] Differentiation of regioisomeric fluoroamphetamine analogs by gas chromatography-mass spectrometry and liquid chromatography-tandem mass spectrometry
    Nakazono, Yukiko
    Tsujikawa, Kenji
    Kuwayama, Kenji
    Kanamori, Tatsuyuki
    Iwata, Yuko T.
    Miyamoto, Kazuna
    Kasuya, Fumiyo
    Inoue, Hiroyuki
    [J]. FORENSIC TOXICOLOGY, 2013, 31 (02) : 241 - 250
  • [2] Electrospray ionization mass spectrometry of tetrodotoxin and its analogs: Liquid chromatography/mass spectrometry, tandem mass spectrometry, and liquid chromatography/tandem mass spectrometry
    Shoji, Y
    Yotsu-Yamashita, M
    Miyazawa, T
    Yasumoto, T
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 290 (01) : 10 - 17
  • [3] Differentiation of regioisomeric chloroamphetamine analogs using gas chromatography–chemical ionization-tandem mass spectrometry
    Shoko Negishi
    Yukiko Nakazono
    Yuko T. Iwata
    Tatsuyuki Kanamori
    Kenji Tsujikawa
    Kenji Kuwayama
    Tadashi Yamamuro
    Kazuna Miyamoto
    Takuya Yamashita
    Fumiyo Kasuya
    Hiroyuki Inoue
    [J]. Forensic Toxicology, 2015, 33 : 338 - 347
  • [4] Differentiation of regioisomeric chloroamphetamine analogs using gas chromatography-chemical ionization-tandem mass spectrometry
    Negishi, Shoko
    Nakazono, Yukiko
    Iwata, Yuko T.
    Kanamori, Tatsuyuki
    Tsujikawa, Kenji
    Kuwayama, Kenji
    Yamamuro, Tadashi
    Miyamoto, Kazuna
    Yamashita, Takuya
    Kasuya, Fumiyo
    Inoue, Hiroyuki
    [J]. FORENSIC TOXICOLOGY, 2015, 33 (02) : 338 - 347
  • [5] Interfacing liquid chromatography with mass spectrometry and tandem mass spectrometry
    Volmer, DA
    Vollmer, DL
    [J]. LC GC NORTH AMERICA, 1996, 14 (03) : 236 - +
  • [6] Liquid chromatography–tandem mass spectrometry
    Mira Petrovic
    Damià Barceló
    [J]. Analytical and Bioanalytical Chemistry, 2013, 405 : 5857 - 5858
  • [7] Analysis of cannabinoids by liquid chromatography— Thermospray mass spectrometry and liquid chromatography— Tandem mass spectrometry
    K. Ndjoko
    J. -L. Wolfender
    K. Hostettmann
    [J]. Chromatographia, 1998, 47 : 72 - 76
  • [8] Analysis of cannabinoids by liquid chromatography - Thermospray mass spectrometry and liquid chromatography - Tandem mass spectrometry
    Ndjoko, K
    Wolfender, JL
    Hostettmann, K
    [J]. CHROMATOGRAPHIA, 1998, 47 (1-2) : 72 - 76
  • [9] Differentiation of ring-substituted bromoamphetamine analogs by gas chromatography–tandem mass spectrometry
    Hiroyuki Inoue
    Shoko Negishi
    Yukiko Nakazono
    Yuko T. Iwata
    Kenji Tsujikawa
    Osamu Ohtsuru
    Kazuna Miyamoto
    Takuya Yamashita
    Fumiyo Kasuya
    [J]. Forensic Toxicology, 2016, 34 : 125 - 132
  • [10] Analysis of small carbohydrates in several bioactive botanicals by gas chromatography with mass spectrometry and liquid chromatography with tandem mass spectrometry
    Moldoveanu, Serban
    Scott, Wayne
    Zhu, Jeff
    [J]. JOURNAL OF SEPARATION SCIENCE, 2015, 38 (21) : 3677 - 3686