Fault ride-through capability improvement in a DFIG-based wind turbine using modified ADRC

被引:0
|
作者
Seyed Reza Mosayyebi
Seyed Hamid Shahalami
Hamed Mojallali
机构
[1] University of Guilan,Electrical Engineering Department, Faculty of Engineering
关键词
Doubly-fed induction generator (DFIG); Auto disturbance rejection control (ADRC); Fault ride-through (FRT); Wind turbine; Nonlinear fractional-order extended state observer (NFESO);
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, an overview of several strategies for fault ride-through (FRT) capability improvement of a doubly-fed induction generator (DFIG)-based wind turbine is presented. Uncertainties and parameter variations have adverse effects on the performance of these strategies. It is desirable to use a control method that is robust to such disturbances. Auto disturbance rejection control (ADRC) is one of the most common methods for eliminating the effects of disturbances. To improve the performance of the conventional ADRC, a modified ADRC is introduced that is more robust to disturbances and offers better responses. The non-derivability of the fal function used in the conventional ADRC degrades its efficiency, so the modified ADRC uses alternative functions that are derivable at all points, i.e., the odd trigonometric and hyperbolic functions (arcsinh, arctan, and tanh). To improve the efficiency of the proposed ADRC, fuzzy logic and fractional-order functions are used simultaneously. In fuzzy fractional-order ADRC (FFOADRC), all disturbances are evaluated using a nonlinear fractional-order extended state observer (NFESO). The performance of the suggested structure is investigated in MATLAB/Simulink. The simulation results show that during disturbances such as network voltage sag/swell, using the modified ADRCs leads to smaller fluctuations in stator flux amplitude and DC-link voltage, lower variations in DFIG velocity, and lower total harmonic distortion (THD) of the stator current. This demonstrates the superiority over conventional ADRC and a proportional-integral (PI) controller. Also, by changing the crowbar resistance and using the modified ADRCs, the peak values of the waveforms (torque and currents) can be controlled at the moment of fault occurrence with no significant distortion.
引用
收藏
相关论文
共 50 条
  • [1] Fault ride-through capability improvement in a DFIG-based wind turbine using modified ADRC
    Mosayyebi, Seyed Reza
    Shahalami, Seyed Hamid
    Mojallali, Hamed
    [J]. PROTECTION AND CONTROL OF MODERN POWER SYSTEMS, 2022, 7 (01)
  • [2] Improving Fault Ride-Through Capability of DFIG-Based Wind Turbine Using Superconducting Fault Current Limiter
    Elshiekh, Mariam E.
    Mansour, Diaa-Eldin A.
    Azmy, Ahmed M.
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (03)
  • [3] Blackstart and Fault Ride-Through Capability of DFIG-Based Wind Turbines
    Dang, Hoang P.
    Pico, Hugo Villegas N.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2023, 14 (03) : 2060 - 2074
  • [4] Coordinated Control of SMES and DVR for Improving Fault Ride-Through Capability of DFIG-based Wind Turbine
    Bouaziz, Fatma
    Masmoudi, Abdelkarim
    Abdelkafi, Achraf
    Krichen, Lotfi
    [J]. INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2022, 12 (01): : 359 - 371
  • [5] Improving the Fault Ride-through Capability of DFIG-Based Wind Turbines Using the Dynamic Impedance
    Liang, Yabo
    Cao, Yunzhu
    Li, Lei
    Sheng, Yaru
    Niu, Jian
    He, Jianan
    [J]. 2022 4TH INTERNATIONAL CONFERENCE ON SMART POWER & INTERNET ENERGY SYSTEMS, SPIES, 2022, : 1185 - 1189
  • [6] Fault Ride-Through Capability Improvement of DFIG-Based Wind Turbine by Employing a Voltage-Compensation-Type Active SFCL
    Chen, Lei
    Zheng, Feng
    Deng, Changhong
    Li, Zhe
    Guo, Fang
    [J]. CANADIAN JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING-REVUE CANADIENNE DE GENIE ELECTRIQUE ET INFORMATIQUE, 2015, 38 (02): : 132 - 142
  • [7] Nonlinear dynamic modeling for fault ride-through capability of DFIG-based wind farm
    M. Kenan Döşoğlu
    [J]. Nonlinear Dynamics, 2017, 89 : 2683 - 2694
  • [8] Nonlinear dynamic modeling for fault ride-through capability of DFIG-based wind farm
    Dosoglu, M. Kenan
    [J]. NONLINEAR DYNAMICS, 2017, 89 (04) : 2683 - 2694
  • [9] Low Voltage Ride-Through Enhancement in DFIG-Based Wind Turbine
    Gatavi, Ehsan
    Hellany, Ali
    Nagrial, Mahmood
    Rizk, Jamal
    [J]. 2016 IEEE ELECTRICAL POWER AND ENERGY CONFERENCE (EPEC), 2016,
  • [10] Fault ride-through capability improvement of DFIG-based wind generation by employing a flux compensation type fault current limiter
    Zhang, Li
    He, Li-ping
    Wang, Sheng-lin
    [J]. 2014 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2014,