Sampling rate and the estimation of ensemble variability for repetitive signals

被引:0
|
作者
P. Laguna
L. Sörnmo
机构
[1] University of Zaragoza,Communication Technology Group
[2] Lund University,Signal Processing Group
关键词
Sampling rate; Ensemble variability; Time-aligned signals; Nyquist rate; ECG database;
D O I
暂无
中图分类号
学科分类号
摘要
The measurement of ensemble variability in time-aligned event signals is studied in relation to sampling rate requirements. The theoretical analysis is based on statistical modelling of time misalignment in which the time resolution is limited by the length of the sampling interval. For different signal-to-noise ratios (SNRs), the sampling rate is derived which limits the misalignment effect to less than 10% of the noise effect. Each signal is assumed to be corrupted by additive noise. Using a normal QRS complex with a high SNR (≈ 30 dB), a sampling rate of approximately 3 kHz is needed for accurate ensemble variability measurements. This result is surprising since it implies that the Nyquist rate is far too low for accurate variability measurements. The theoretical results are supplemented with results obtained from an ECG database of 94 subjects for which the ensemble variability is computed at different sampling rates using signal interpolation. The ensemble variability is substantially reduced (40%) when increasing the rate from 1 to 3 kHz, thus corroborating the results suggested by the theoretical analysis.
引用
收藏
页码:540 / 546
页数:6
相关论文
共 50 条
  • [1] Sampling rate and the estimation of ensemble variability for repetitive signals
    Laguna, P
    Sörnmo, L
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2000, 38 (05) : 540 - 546
  • [2] Sampling rate and time alignment in the estimation of QRS variability
    Laguna, P
    Sörnmo, L
    [J]. PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 159 - 162
  • [3] Adaptive repetitive control to track variable periodic signals with fixed sampling rate
    Cao, ZW
    Ledwich, GF
    [J]. IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2002, 7 (03) : 378 - 384
  • [4] Heart Rate Variability Estimation in Electrocardiogram Signals Interferences Based on Photoplethysmography Signals
    Zhang, Aihua
    Wang, Qian
    Chou, Yongxin
    [J]. INTELLIGENT COMPUTING METHODOLOGIES, ICIC 2016, PT III, 2016, 9773 : 149 - 159
  • [5] Sampling Signals with Finite Rate of Innovation and Recovery by Maximum Likelihood Estimation
    Hirabayashi, Akira
    Hironaga, Yosuke
    Condat, Laurent
    [J]. IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2013, E96A (10) : 1972 - 1979
  • [6] HEURISTIC ESTIMATION DETECTION OF REPETITIVE SIGNALS
    EISENSTEIN, BA
    [J]. IEEE TRANSACTIONS ON SYSTEMS MAN AND CYBERNETICS, 1976, 6 (07): : 480 - 485
  • [7] SAMPLING WIDEBAND, NON-REPETITIVE RADAR SIGNALS
    FINDLAY, AM
    ORNSTEIN, E
    [J]. IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1975, 11 (03) : 424 - 424
  • [8] Heart rate variability estimation in photoplethysmography signals using Bayesian learning approach
    Alqaraawi, Ahmed
    Alwosheel, Ahmad
    Alasaad, Amr
    [J]. HEALTHCARE TECHNOLOGY LETTERS, 2016, 3 (02) : 136 - 142
  • [9] Heart rate variability with repetitive exposure to music
    Iwanaga, M
    Kobayashi, A
    Kawasaki, C
    [J]. BIOLOGICAL PSYCHOLOGY, 2005, 70 (01) : 61 - 66
  • [10] Sampling signals with finite rate of innovation
    Vetterli, M
    Marziliano, P
    Blu, T
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2002, 50 (06) : 1417 - 1428