A third-generation hydrogen peroxide biosensor based on horseradish peroxidase cross-linked to multi-wall carbon nanotubes

被引:0
|
作者
Shuxia Xu
Xinfeng Zhang
Tao Wan
Chengxiao Zhang
机构
[1] Chengdu University of Technology,College of Materials and Chemistry & Chemical Engineering
[2] Shaanxi Normal University,School of Chemical and Materials Science
来源
Microchimica Acta | 2011年 / 172卷
关键词
Horseradish peroxidase; Direct electron transfer; Multi-walled carbon nanotubes; Biosensor;
D O I
暂无
中图分类号
学科分类号
摘要
A novel third generation biosensor for hydrogen peroxide (HP) was constructed by crosslinking horseradish peroxidase (HRP) onto an electrode modified with multi-wall carbon nanotubes (MWNTs). Glutaraldehyde and bovine serum albumin were used to cross-link HRP and the MWNTs. Scanning electron microscopy revealed that HRP was evenly distributed on the surface of the nanotubes. Factors influencing the performance of the biosensor were studied in detail. The biosensor exhibited a fast amperometric response (2.0 s) to HP which is linear in the concentration range from 9.5 mM to 0.95 μM. The detection of limit is 0.4 μM. The sensor exhibits good stability and durability (on testing 0.1 mM solution of HP over a period of 10 days), with a long-term relative standard deviation of <5%.
引用
收藏
页码:199 / 205
页数:6
相关论文
共 50 条
  • [1] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase cross-linked to multi-wall carbon nanotubes
    Xu, Shuxia
    Zhang, Xinfeng
    Wan, Tao
    Zhang, Chengxiao
    MICROCHIMICA ACTA, 2011, 172 (1-2) : 199 - 205
  • [2] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase immobilized on DNA functionalized carbon nanotubes
    Zeng, Xiandong
    Li, Xuefang
    Liu, Xiaoying
    Liu, Yong
    Luo, Shenglian
    Kong, Bo
    Yang, Shanli
    Wei, Wanzhi
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 896 - 900
  • [3] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase immobilized by sol gel thin film on a multi-wall carbon nanotube modified electrode
    Xu, Shu-Xia
    Li, Jia-Ling
    Zhou, Zhi-Ling
    Zhang, Cheng-Xiao
    ANALYTICAL METHODS, 2014, 6 (16) : 6310 - 6315
  • [4] A Third-Generation Hydrogen Peroxide Biosensor Based on Horseradish Peroxidase Immobilized in Carbon Nanotubes/ SBA-15 Film
    Fang, Zheng-Hui
    Lu, Li-Min
    Zhang, Xiao-Bing
    Li, Hong-Bo
    Yang, Bin
    Shen, Guo-Li
    Yu, Ru-Qin
    ELECTROANALYSIS, 2011, 23 (10) : 2415 - 2420
  • [5] A third-generation hydrogen peroxide biosensor based on horseradish peroxidase immobilized in a tetrathiafulvalene-tetracyanoquinodimethane/multiwalled carbon nanotubes film
    Cao, Zhijun
    Jiang, Xueqin
    Xie, Qingji
    Yao, Shouzhuo
    BIOSENSORS & BIOELECTRONICS, 2008, 24 (02): : 222 - 227
  • [6] A third-generation biosensor for hydrogen peroxide based on the immobilization of horseradish peroxidase on a disposable carbon nanotubes modified screen–printed electrode
    Shuxia Xu
    Xiaojiao Qin
    Xinfeng Zhang
    Chengxiao Zhang
    Microchimica Acta, 2015, 182 : 1241 - 1246
  • [7] A third-generation biosensor for hydrogen peroxide based on the immobilization of horseradish peroxidase on a disposable carbon nanotubes modified screen-printed electrode
    Xu, Shuxia
    Qin, Xiaojiao
    Zhang, Xinfeng
    Zhang, Chengxiao
    MICROCHIMICA ACTA, 2015, 182 (7-8) : 1241 - 1246
  • [8] A third-generation hydrogen peroxide biosensor based on Horseradish Peroxidase (HRP) enzyme immobilized in a Nafion-Sonogel-Carbon composite
    Elkaoutit, Mohammed
    Naranjo-Rodriguez, Ignacio
    Dominguez, Manuel
    Hernandez-Artiga, Maria P.
    Bellida-Milla, Dolores
    Luis Hidalgo-Hidalgo de Cisneros, Jose
    ELECTROCHIMICA ACTA, 2008, 53 (24) : 7131 - 7137
  • [9] A biosensor based on immobilization of horseradish peroxidase in chitosan matrix cross-linked with glyoxal for amperometric determination of hydrogen peroxide
    Wang, HS
    Pan, QX
    Wang, GX
    SENSORS, 2005, 5 (4-5): : 266 - 276
  • [10] Amperometric third-generation hydrogen peroxide biosensor incorporating multiwall carbon nanotubes and hemoglobin
    Qi, HL
    Zhang, CX
    Li, XR
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01) : 364 - 370