Erratum to: An integrated disposable device for DNA extraction and helicase dependent amplification

被引:0
|
作者
Madhumita Mahalanabis
Jaephil Do
Hussam ALMuayad
Jane Y. Zhang
Catherine M. Klapperich
机构
[1] Boston University,Department of Biomedical Engineering
[2] Boston University,Department of Mechanical Engineering
来源
Biomedical Microdevices | 2011年 / 13卷
关键词
DNA; Bacteria; Helicase dependent amplification; Isothermal amplification; Microfluidic chip; Plastic; Solid phase extraction;
D O I
暂无
中图分类号
学科分类号
摘要
In the original manuscript, we reported the demonstration of an integrated microfluidic chip that performed helicase dependent amplification (HDA) on samples containing live bacteria. Bacterial lysis, nucleic acid extraction, and DNA amplification with a fluorescent reporter were incorporated into a disposable polymer cartridge format. We reported that the device was able to detect as few as 10 colony-forming units (CFU) of E. coli in growth medium. While the main conclusions of the original paper remain sound, the data presented in support of those conclusions contained errors that we detail, discuss and correct here. In short, we misidentified a non-specific product as a specific product of our HDA reaction. We incorrectly called reactions containing the non-specific product (length 70 bp) positive. Further investigation demonstrated that our primer set was faulty and not capable of amplifying the specific product. Here we redesigned primers, sequenced all of the products and reran all of the experiments reported previously to generate a new, verified dataset.
引用
收藏
页码:599 / 602
页数:3
相关论文
共 50 条
  • [1] An integrated disposable device for DNA extraction and helicase dependent amplification
    Madhumita Mahalanabis
    Jaephil Do
    Hussam ALMuayad
    Jane Y. Zhang
    Catherine M. Klapperich
    Biomedical Microdevices, 2010, 12 : 353 - 359
  • [2] An integrated disposable device for DNA extraction and helicase dependent amplification
    Mahalanabis, Madhumita
    do, Jaephil
    ALMuayad, Hussam
    Zhang, Jane Y.
    Klapperich, Catherine M.
    BIOMEDICAL MICRODEVICES, 2010, 12 (02) : 353 - 359
  • [3] An integrated disposable device for DNA extraction and helicase dependent amplification (vol 12, pg 353, 2010)
    Mahalanabis, Madhumita
    Do, Jaephil
    Almuayad, Hussam
    Zhang, Jane Y.
    Klapperich, Catherine M.
    BIOMEDICAL MICRODEVICES, 2011, 13 (03) : 599 - 602
  • [4] Helicase‐dependent isothermal DNA amplification
    Myriam Vincent
    Yan Xu
    Huimin Kong
    The EMBO Reports, 2004, 5 (8): : 795 - 800
  • [5] Helicase-dependent isothermal DNA amplification
    Vincent, M
    Xu, Y
    Kong, HM
    EMBO REPORTS, 2004, 5 (08) : 795 - 800
  • [6] A fully disposable and integrated paper-based device for nucleic acid extraction, amplification and detection
    Tang, Ruihua
    Yang, Hui
    Gong, Yan
    You, MinLi
    Liu, Zhi
    Choi, Jane Ru
    Wen, Ting
    Qu, Zhiguo
    Mei, Qibing
    Xu, Feng
    LAB ON A CHIP, 2017, 17 (07) : 1270 - 1279
  • [7] Integrated DNA extraction and amplification using electrokinetic pumping in a microfluidic device
    Parton, Joseph
    Birch, Christopher
    Kemp, Cordula
    Haswell, Stephen J.
    Pamme, Nicole
    Shaw, Kirsty J.
    ANALYTICAL METHODS, 2012, 4 (01) : 96 - 100
  • [8] Enhancing helicase-dependent amplification by fusing the helicase with the DNA polymerase
    Motre, Aurelie
    Li, Ying
    Kong, Huimin
    GENE, 2008, 420 (01) : 17 - 22
  • [9] Isothermal DNA amplification in vitro: the helicase-dependent amplification system
    Jeong, Yong-Joo
    Park, Kkothanahreum
    Kim, Dong-Eun
    CELLULAR AND MOLECULAR LIFE SCIENCES, 2009, 66 (20) : 3325 - 3336
  • [10] Isothermal DNA amplification in vitro: the helicase-dependent amplification system
    Yong-Joo Jeong
    Kkothanahreum Park
    Dong-Eun Kim
    Cellular and Molecular Life Sciences, 2009, 66