Startup of air-cooled condensers and dry cooling towers at low temperatures of the cooling air

被引:1
|
作者
Milman O.O. [1 ]
Ptakhin A.V. [1 ]
Kondratev A.V. [1 ]
Shifrin B.A. [1 ]
Yankov G.G. [2 ]
机构
[1] ZAO Turbokon Scientific and Production Implementation Company, ul. Komsomolskaya Roshcha 43, Kaluga
[2] Moscow Power Engineering Institute (MPEI, National Research University), ul. Krasnokazarmennaya 14, Moscow
来源
Milman, O.O. (turbocon@kaluga.ru) | 1600年 / Izdatel'stvo Nauka卷 / 63期
关键词
air-cooled condenser; condensation; dry cooling tower; electric heating; heating steam; shutdown; startup;
D O I
10.1134/S0040601516050074
中图分类号
学科分类号
摘要
The problems of startup and performance of air-cooled condensers (ACC) and dry cooling towers (DCT) at low cooling air temperatures are considered. Effects of the startup of the ACC at sub-zero temperatures are described. Different options of the ACC heating up are analyzed, and examples of existing technologies are presented (electric heating, heating up with hot air or steam, and internal and external heating). The use of additional heat exchanging sections, steam tracers, in the DCT design is described. The need for high power in cases of electric heating and heating up with hot air is noted. An experimental stand for research and testing of the ACC startup at low temperatures is described. The design of the three-pass ACC unit is given, and its advantages over classical single-pass design at low temperatures are listed. The formation of ice plugs inside the heat exchanging tubes during the start-up of ACC and DCT at low cooling air temperatures is analyzed. Experimental data on the effect of the steam flow rate, steam nozzle distance from the heat-exchange surface, and their orientation in space on the metal temperature were collected, and test results are analyzed. It is noted that the surface temperature at the end of the heat up is almost independent from its initial temperature. Recommendations for the safe start-up of ACCs and DCTs are given. The heating flow necessary to sufficiently heat up heat-exchange surfaces of ACCs and DCTs for the safe startup is estimated. The technology and the process of the heat up of the ACC with the heating steam external supply are described by the example of the startup of the full-scale section of the ACC at sub-zero temperatures of the cooling air, and the advantages of the proposed start-up technology are confirmed. © 2016, Pleiades Publishing, Inc.
引用
收藏
页码:329 / 335
页数:6
相关论文
共 50 条
  • [1] Cooling Performance Enhancement of Air-Cooled Condensers by Guiding Air Flow
    Huang, Xianwei
    Chen, Lin
    Yang, Lijun
    Du, Xiaoze
    Yang, Yongping
    [J]. ENERGIES, 2019, 12 (18)
  • [2] Aerodynamic numerical calculations of air-cooled condensers and dry cooling towers at different wind velocities and multilevel configuration of sections
    Milman, Oleg
    Lenev, Sergey
    Golov, Pavel
    Shifrin, Boris
    Kartuesova, Anna
    [J]. XXXIII SIBERIAN THERMOPHYSICAL SEMINAR (STS-33), 2017, 115
  • [3] WIND EFFECTS ON AIR-COOLED CONDENSERS FOR POWER PLANT COOLING
    Maulbetsch, John S.
    DiFilippo, Michael N.
    Owen, Michael
    Kroger, Detlev G.
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 4: HEAT TRANSFER MEASUREMENT TECHNIQUES, HEAT TRANSFER EQUIPMENT, THERMOELECTRICS, 2010, : 809 - 816
  • [4] TESTING STAGE FOR WET AND DRY COOLING-TOWERS AND OTHER AIR-COOLED APPARATUSES
    STUTTGAR, CW
    [J]. BRENNSTOFF-WARME-KRAFT, 1973, 25 (12): : 474 - 475
  • [5] Testing Wet and Dry Cooling Towers, as Well as Other Air-Cooled Equipment.
    Walter, C.
    [J]. 1600, (25):
  • [6] RECOOLING PLANTS, AIR-COOLED CONDENSERS, EVAPORATIVE COOLERS, EVAPORATIVE CONDENSERS, AIR-COOLED WATER COOLERS (DRY-AIR COOLERS)
    PIELKE, R
    [J]. KALTE UND KLIMATECHNIK, 1978, 31 (05): : 234 - &
  • [7] AIR-COOLED OVERHEAD CONDENSERS
    DEHNE, MF
    [J]. CHEMICAL ENGINEERING PROGRESS, 1969, 65 (07) : 51 - &
  • [8] OPTIMIZATION OF AIR-COOLED CONDENSERS
    LAU, SC
    ANNAMALAI, K
    SHELTON, SV
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1987, 109 (02): : 90 - 95
  • [9] Cooling Airflow, Losses, and Temperatures in Large Air-Cooled Synchronous Machines
    Traxler-Samek, Georg
    Zickermann, Richard
    Schwery, Alexander
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (01) : 172 - 180
  • [10] APPLICATION OF AN AIR-COOLED CONDENSATION AND COOLING SYSTEM
    GORETZKO, G
    [J]. CHEMISCHE TECHNIK, 1969, 21 (08): : 507 - &