Surgical nuances and construct patterns influence construct stiffness in C1-2 stabilizations: a biomechanical study of C1-2 gapping and advanced C1-2 fixation

被引:0
|
作者
Heiko Koller
Sebastian Hartmann
Gmeiner Raphael
Werner Schmölz
Christoph Orban
Claudius Thome
机构
[1] Technical University of Munich (TUM),Department of Neurosurgery
[2] Paracelsus Medical University Austria,Department of Neurosurgery
[3] Medical University Innsbruck,Department of Trauma Surgery
[4] Medical University Innsbruck,undefined
来源
European Spine Journal | 2021年 / 30卷
关键词
Biomechanical study; C1-2; Instrumentation; Mechanical testing; Gapping; Construct stability; Implant pattern; ROM;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1596 / 1606
页数:10
相关论文
共 50 条
  • [1] Surgical nuances and construct patterns influence construct stiffness in C1-2 stabilizations: a biomechanical study of C1-2 gapping and advanced C1-2 fixation
    Koller, Heiko
    Hartmann, Sebastian
    Raphael, Gmeiner
    Schmoelz, Werner
    Orban, Christoph
    Thome, Claudius
    EUROPEAN SPINE JOURNAL, 2021, 30 (06) : 1596 - 1606
  • [2] C1-ring osteosynthesis versus C1-2 fixation in terms of C1-2 stability
    Hyub, Sang
    Park, Jin Hoon
    JOURNAL OF NEUROSURGERY-SPINE, 2023, 39 (01)
  • [3] Biomechanical comparison of C1-2 posterior fixation techniques
    Hott, JS
    Lynch, JJ
    Chamberlain, RH
    Sonntag, VKH
    Crawford, NR
    JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (02) : 175 - 181
  • [4] C1-2 ARTHROGRAPHY
    CHEVROT, A
    CERMAKOVA, E
    VALLEE, C
    CHANCELIER, MD
    CHEMLA, N
    ROUSSELIN, B
    LANGERCHERBIT, A
    SKELETAL RADIOLOGY, 1995, 24 (06) : 425 - 429
  • [5] Biomechanical characteristics of C1-2 cable fixations
    Dickman, CA
    Crawford, NR
    Paramore, CG
    JOURNAL OF NEUROSURGERY, 1996, 85 (02) : 316 - 322
  • [6] Combination of skull traction with posterior C1-2 fusion for old C1-2 dislocations
    Li, Xue Feng
    Yang, Hui Lin
    Jiang, Wei Min
    Tang, Tian Si
    Gong, Xiao Hong
    Yuan, Jing
    Zhang, Ji Gang
    Wang, Gen Lin
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (06) : 768 - 773
  • [7] ANTERIOR SCREW FIXATION FOR C1-2 INSTABILITY
    APFELBAUM, RI
    JOURNAL OF NEUROSURGERY, 1989, 70 (02) : A316 - A316
  • [8] Biomechanical analysis of Goel technique for C1-2 fusion
    Park, Jon
    Scheer, Justin K.
    Lim, T. Jesse
    Deviren, Vedat
    Ames, Christopher P.
    JOURNAL OF NEUROSURGERY-SPINE, 2011, 14 (05) : 639 - 646
  • [9] RHEUMATOID C1-2 SPINAL INSTABILITY
    EWEND, M
    DUCKER, TB
    JOURNAL OF SPINAL DISORDERS, 1993, 6 (06): : 535 - 536
  • [10] Novel Technique for C1-2 Interlaminar Arthrodesis Utilizing a Modified Sonntag Loop-Suture Graft With Posterior C1-2 Fixation
    Koffie, Robert M.
    Larsen, Alexandra M. Giantini
    Grannan, Benjamin L.
    Hadzipasic, Muhamed
    Yanamadala, Vijay
    Van Beaver, Laura
    Shankar, Ganesh M.
    Shin, John H.
    NEUROSPINE, 2020, 17 (03) : 659 - 665