Experimental periprosthetic fractures with collarless polished tapered cemented stems

被引:0
|
作者
Takuma Yagura
Kenichi Oe
Fumito Kobayasi
Shohei Sogawa
Tomohisa Nakamura
Hirokazu Iida
Takanori Saito
机构
[1] Kansai Medical University,Department of Orthopaedic Surgery
来源
关键词
Bone cement; Falling-weight impact test; Periprosthetic fracture; Staircase method; Taper-slip stem;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1171 / 1178
页数:7
相关论文
共 50 条
  • [1] Experimental periprosthetic fractures with collarless polished tapered cemented stems
    Yagura, Takuma
    Oe, Kenichi
    Kobayasi, Fumito
    Sogawa, Shohei
    Nakamura, Tomohisa
    Iida, Hirokazu
    Saito, Takanori
    INTERNATIONAL ORTHOPAEDICS, 2024, 48 (05) : 1171 - 1178
  • [2] Periprosthetic fractures around polished collarless cemented stems: the effect of stem design on fracture pattern
    Erhardt, Johannes B.
    Khoo, Paul P.
    Stoffel, Karl K.
    Yates, Piers J.
    HIP INTERNATIONAL, 2013, 23 (05) : 459 - 464
  • [3] Outcomes following osteosynthesis of periprosthetic hip fractures around cemented tapered polished stems
    Goudie, S. T.
    Patil, S.
    Patton, J. T.
    Keating, J. F.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (10): : 2194 - 2200
  • [4] Principles of managing Vancouver type B periprosthetic fractures around cemented polished tapered femoral stems
    Quah C.
    Porteous M.
    Stephen A.
    European Journal of Orthopaedic Surgery & Traumatology, 2017, 27 (4) : 477 - 482
  • [5] Fretting corrosion of fully cemented polished collarless tapered stems: The influence of PMMA bone cement
    Bryant, M.
    Farrar, R.
    Brummitt, K.
    Freeman, R.
    Neville, A.
    WEAR, 2013, 301 (1-2) : 290 - 299
  • [6] Which Unified Classification System type B periprosthetic fractures around cemented polished tapered stems should not be fixed?
    Scott, C. E. H.
    Jain, S.
    Moran, M.
    Haddad, F. S.
    BONE & JOINT JOURNAL, 2023, 105B (05): : 481 - 486
  • [7] An atypical periprosthetic fracture in collarless, polished, tapered, cemented stems of total hip arthroplasty: A report of five SC-stem cases and literature review
    Oe, Kenichi
    Iida, Hirokazu
    Hirata, Masayuki
    Kawamura, Hiroshi
    Ueda, Narumi
    Nakamura, Tomohisa
    Okamoto, Naofumi
    Saito, Takanori
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (06) : 1422 - 1429
  • [8] Polished, Collarless, Tapered, Cemented Stems for Primary Hip Arthroplasty May Exhibit High Rate of Periprosthetic Fracture at Short-Term Follow-Up
    Scott, Trevor
    Salvatore, Anthony
    Woo, Pauline
    Lee, Yuo-yu
    Salvati, Eduardo A.
    Della Valle, Alejandro Gonzalez
    JOURNAL OF ARTHROPLASTY, 2018, 33 (04): : 1120 - 1125
  • [9] Polished tapered stems in total hip arthroplasty SURVIVAL AND RISK FACTORS FOR PERIPROSTHETIC FRACTURES
    Kayani, B.
    Luo, T. D.
    Haddad, F. S.
    BONE & JOINT JOURNAL, 2024, 106B (03): : 220 - 223
  • [10] Fretting corrosion characteristics of polished collarless tapered stems in a simulated biological environment
    Bryant, Michael
    Farrar, Richard
    Freeman, Robert
    Brummitt, Ken
    Neville, Anne
    TRIBOLOGY INTERNATIONAL, 2013, 65 : 105 - 112