Lateral radiological evaluation of transarticular screw placement in the lower cervical spine

被引:0
|
作者
Rongming Xu
Liujun Zhao
Bo Chai
Weihu Ma
Huajie Xia
Guoping Wang
Weiyu Jiang
机构
[1] Ningbo 6th Hospital,Department of Orthopaedic Surgery
[2] XiangXing Hospital,Department of Orthopaedic Surgery
[3] Ningbo 6th Hospital,Department of Radiology
来源
European Spine Journal | 2009年 / 18卷
关键词
Lower cervical spine; Transarticular screw placement; Cervical radiograph; Nerve root injury;
D O I
暂无
中图分类号
学科分类号
摘要
This study assessed the ideal district of lateral radiograph in evaluation of transarticular screw placement in the lower cervical spine. To assess the ideal zone of lateral radiographs in determining the safe or hazardous locations of the screw tips during transarticular screw implantation in the lower cervical spine. Transarticular screw in the lower cervical spine had been used as an alternative technique to achieve posterior cervical spine stability. Injury to the spinal nerves caused by transarticular screws which are too long must be identified quickly to minimize the neurologic complication. No previous radiological study regarding evaluation of the transarticular screw placement using lateral radiographs has been reported. Twelve cervical spines were removed from embalmed cadavers. Four transarticular screw placements with Dalcanto’s technique under direct visualization, including placement of the screw tip staying the ventral cortex, 2, 4 and 6 mm over-penetration of the ventral cortex, were performed on each specimen. Following each placement, a lateral radiograph was taken. Each vertebral body was divided vertically into four equal zones, and another equal zone posterior to the posterior border of the vertebral body was defined as Zone pre-1. The numbers of screw tips seen in each zone were quantified for each placement. Partitions of χ2 method was used to evaluate the ideal zone on lateral radiograph for transarticular screw insertion. At C34 and C45, no significant difference was found between Zone pre-1 and Zone 1 (χ2 = 0.18, P > 0.50), while there was significant difference between Zones 1 and 2 (χ2 = 73.6, P < 0.005), as well as Zones 2 and 3 (χ2 = 13.2, P < 0.005). At C56 and C67, No significant difference was found between Zones 2 and 3 (χ2 = 0.25, P > 0.50), while there was significant difference between Zone pre-1 and Zone 1 (χ2 = 66.2, P < 0.005), as well as Zones 1 and 2 (χ2 = 10.5, P < 0.005). Ideal screw tip positions on lateral radiograph for transarticular screw by Dalcanto’s technique should be in Zone 1 at C34 and C45, in Zone pre-1 at C56 and C67. If the screw tip was in Zones 3 and 4, the safe rate will be decreased significantly and it might be too deep and be dangerous.
引用
收藏
页码:392 / 397
页数:5
相关论文
共 50 条
  • [1] Lateral radiological evaluation of transarticular screw placement in the lower cervical spine
    Xu, Rongming
    Zhao, Liujun
    Chai, Bo
    Ma, Weihu
    Xia, Huajie
    Wang, Guoping
    Jiang, Weiyu
    EUROPEAN SPINE JOURNAL, 2009, 18 (03) : 392 - 397
  • [2] The Study on Comparison of 3 Techniques for Transarticular Screw Placement in the Lower Cervical Spine
    Zhao, Liujun
    Xu, Rongming
    Liu, Jiayong
    Sochacki, Kyle R.
    Ma, Weihu
    Jiang, Weiyu
    Liu, Guanyi
    Cao, Jin
    Hua, Qun
    SPINE, 2012, 37 (08) : E468 - E472
  • [3] Lateral radiologic evaluation of lateral mass screw placement in the cervical spine
    Ebraheim, NA
    Tremains, MR
    Xu, RM
    Yeasting, RA
    SPINE, 1998, 23 (04) : 458 - 462
  • [4] Transarticular screw fixation in the middle and lower cervical spine - Technical note
    Takayasu, M
    Hara, M
    Yamauchi, K
    Yoshida, M
    Yoshida, J
    JOURNAL OF NEUROSURGERY, 2003, 99 (01) : 132 - 136
  • [5] Modified Magerl technique of lateral mass screw placement in the lower cervical spine: An anatomic study
    Xu, RM
    Ebraheim, NA
    Klausner, T
    Yeasting, RA
    JOURNAL OF SPINAL DISORDERS, 1998, 11 (03): : 237 - 240
  • [6] CT evaluation of upper thoracic spine for surgical application of transarticular screw placement
    Yang Yu
    Ning Xie
    Bin Ni
    Kai Liu
    Qunfeng Guo
    Jian Yang
    Zhuangchen Zhu
    Junsheng Luo
    European Spine Journal, 2012, 21 : 1186 - 1191
  • [7] CT evaluation of upper thoracic spine for surgical application of transarticular screw placement
    Yu, Yang
    Xie, Ning
    Ni, Bin
    Liu, Kai
    Guo, Qunfeng
    Yang, Jian
    Zhu, Zhuangchen
    Luo, Junsheng
    EUROPEAN SPINE JOURNAL, 2012, 21 (06) : 1186 - 1191
  • [8] Minimally Invasive Cervical Spine Foraminotomy and Lateral Mass Screw Placement
    Mikhael, Mark M.
    Celestre, Paul C.
    Wolf, Christopher F.
    Mroz, Tom E.
    Wang, Jeffrey C.
    SPINE, 2012, 37 (05) : E318 - E322
  • [9] Safe placement of lateral mass screw in the subaxial cervical spine: a case series
    Zhang, Di
    Gao, Xianda
    Jiang, Jiang
    Kong, Fanlong
    Shen, Yong
    Ding, Wenyuan
    Hao, Xiufang
    Cui, Huixian
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (04) : 781 - 788
  • [10] Safe placement of lateral mass screw in the subaxial cervical spine: a case series
    Di Zhang
    Xianda Gao
    Jiang Jiang
    Fanlong Kong
    Yong Shen
    Wenyuan Ding
    Xiufang Hao
    Huixian Cui
    International Orthopaedics, 2017, 41 : 781 - 788