Mass effect analysis of a coil spring for the performance evaluation of a gas insulated circuit breaker

被引:0
|
作者
Dae-Woo Lee
Jeong-Hyun Sohn
Wan-Suk Yoo
机构
[1] Pukyong National University,Graduate School of Mechanical Design Engineering
[2] Pukyong National University,Department of Mechanical & Automotive Engineering
[3] Pusan National University,Department of Mechanical Engineering
关键词
Gas insulated circuit breaker; Spring operating mechanism; Coil spring; Mass effect; Flexible multibody dynamics;
D O I
暂无
中图分类号
学科分类号
摘要
Since the performance of a circuit breaker which has the spring operating mechanism mainly depends on the dynamic behavior of a coil spring, the analysis of the dynamic behavior of a coil spring is required for a performance evaluation of a circuit breaker. When a spring moves so fast from the releasing state, a lot of energy is used to move a self-weight of a spring. Thus, the mass effect analysis of a spring operating mechanism is required for the performance evaluation of a circuit breaker accurately. In this study, a release test bed is designed for evaluating the dynamic behaviors of a coil spring. Three types of spring models such as a linear spring model, a nodal spring model and a lumped parameter spring model are established for comparing the modeling error of a spring due to the mass effect. RecurDyn is employed to carry out the computer simulation and results are compared with test results. The actual energy transferred to the follower during high-speed motion is analyzed through the comparisons of the kinetic energy between the experiment and the computer simulation.
引用
收藏
页码:2543 / 2548
页数:5
相关论文
共 50 条
  • [1] Mass effect analysis of a coil spring for the performance evaluation of a gas insulated circuit breaker
    Lee, Dae-Woo
    Sohn, Jeong-Hyun
    Yoo, Wan-Suk
    INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2014, 15 (12) : 2543 - 2548
  • [2] Experiment and Simulation of a Coil Spring for the Performance Evaluation of a Gas Insulated Circuit Breaker
    Lee, Dae Woo
    Bae, Byung Tae
    Kim, Min Soo
    Yoo, Wan Suk
    Kim, Jae Yeol
    Sohn, Jeong Hvun
    Kim, Hyun Woo
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 422 - 424
  • [3] Study on The friction characteristics of Canted coil spring for Gas insulated circuit breaker
    Park, Joo-Eon
    Lee, Sung-Ho
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 407 - 409
  • [4] Performance Circuit Breaker for Gas-insulated Switching.
    Ragaller, K.
    Bulletin de l'Association suisse des electriciens, 1983, 74 (21): : 1242 - 1246
  • [5] Performance improvement of spring operating mechanism for gas insulated circuite breaker by optimizing latch mechanism
    Kim, Hyun-Woo
    Kim, Jin-Ho
    Lee, Sung-Ho
    Jang, Jin-Seok
    Kim, Jae-Yeol
    Yoo, Wan-Suk
    Bae, Byung-Tae
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 410 - 411
  • [6] Performance improvement of a gas-insulated circuit breaker using multibody dynamic simulations and experiments
    Gyuseok Choi
    Jeonghyun Sohn
    Hyunwoo Kim
    Wansuk Yoo
    Byungtae Bae
    Jaeyeol Kim
    Jinho Kim
    Journal of Mechanical Science and Technology, 2013, 27 : 3223 - 3229
  • [7] Performance improvement of a gas-insulated circuit breaker using multibody dynamic simulations and experiments
    Choi, Gyuseok
    Sohn, Jeonghyun
    Kim, Hyunwoo
    Yoo, Wansuk
    Bae, Byungtae
    Kim, Jaeyeol
    Kim, Jinho
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2013, 27 (11) : 3223 - 3229
  • [8] On the design of spring-actuated mechanism for 69KV SF6 gas insulated circuit breaker
    Chen, FC
    JOURNAL OF MECHANICAL DESIGN, 2003, 125 (04) : 840 - 845
  • [9] Modeling of Dynamic Characteristics for Spring Operating Gas Circuit Breaker
    Hashimoto, H.
    Okubo, K.
    2014 IEEE PES T&D CONFERENCE AND EXPOSITION, 2014,
  • [10] Dynamic response of spring-type operating mechanism for 69 kV SF6 gas insulated circuit breaker
    Chen, FC