The aim of this study was to elucidate flow patterns of two different types of aortic cannulas inserted from the ascending aorta toward the aortic arch and root by mock circulation in a normal aortic arch and an aortic arch aneurysm model. Extracorporeal circulation was established using a centrifugal pump, a transparent glass normal aortic arch model, and an aortic arch aneurysm model for measurement by particle image velocimetry. The Stealthflow and Dispersion cannulas were used to elucidate the characteristics of the flow pattern and velocity under the condition of the cannula tip toward the aortic arch and aortic root. In the normal aortic arch model, high-velocity exit flow ranging from 0.7 to 0.8 m/s was detected in the proximal aortic arch by directing the cannula tip toward the aortic arch, whereas flow velocity in the aortic arch was < 0.2 m/s by directing the cannula tip toward the aortic root. In the aortic arch aneurysm model, high-velocity exit flow ranging from 0.5 to 0.8 m/s was detected in the aortic arch by directing the cannula tip toward the aortic arch, whereas flow velocity in the aortic arch was decreased to less than 0.2 m/s by directing the cannula tip toward the aortic root. Directing the aortic cannula tip toward the aortic root allowed the high-velocity exit flow to attenuate in velocity, so that flow velocity in the aortic arch was sufficiently reduced by reversed flow and vortex formation in both the normal and aortic arch aneurysm models.
引用
收藏
页码:442 / 449
页数:7
相关论文
共 50 条
  • [1] Flow analysis during mock circulation in normal and aortic arch aneurysm models through an aortic cannula toward the aortic arch and root
    Goto, Takeshi
    Fukuda, Ikuo
    Inamura, Takao
    Shirota, Minori
    Minakawa, Masahito
    [J]. JOURNAL OF ARTIFICIAL ORGANS, 2021, 24 (04) : 442 - 449
  • [2] Hydrodynamics of Aortic Cannulae During Extracorporeal Circulation in a Mock Aortic Arch Aneurysm Model
    Minakawa, Masahito
    Fukuda, Ikuo
    Igarashi, Takao
    Fukui, Kozo
    Yanaoka, Hideki
    Inamura, Takao
    [J]. ARTIFICIAL ORGANS, 2010, 34 (02) : 105 - 112
  • [3] Interrupted Aortic Arch and Aortic Root Aneurysm and Dissection
    Zhang, Xiaoyong
    Li, Wuchao
    [J]. RADIOLOGY, 2024, 311 (02)
  • [4] EFFECT OF CANNULA LENGTH ON AORTIC-ARCH FLOW - PROTECTION OF THE ATHEROMATOUS AORTIC-ARCH
    GROSSI, EA
    KANCHUGER, MS
    SCHWARTZ, DS
    MCLOUGHLIN, DE
    LEBOUTILLIER, M
    RIBAKOVE, GH
    MARSCHALL, KE
    GALLOWAY, AC
    COLVIN, SB
    [J]. ANNALS OF THORACIC SURGERY, 1995, 59 (03): : 710 - 712
  • [5] Endovascular Aortic Arch Aneurysm Repair With a Bovine Aortic Arch
    Fang, Zachary B.
    Judelson, Dejah R.
    Simons, Jessica P.
    Schanzer, Andres
    [J]. JOURNAL OF VASCULAR SURGERY, 2022, 75 (06) : E240 - E240
  • [6] Total arch replacement for a distal aortic arch aneurysm with right aortic arch
    Kiokawa, Keiko
    Goh, Kazutomo
    Akasaka, Nobuyuki
    Azuma, Nobuyoshi
    Inaba, Masashi
    Sasajima, Tadahiro
    [J]. ANNALS OF THORACIC SURGERY, 2007, 83 (02): : E3 - E5
  • [7] Echocardiographic and radiographic imaging of aortic root and aortic arch aneurysm in the horse
    Stadler, P
    Wohlsein, P
    Gratopp, M
    Seiffert, B
    Soulier, A
    [J]. PFERDEHEILKUNDE, 1996, 12 (02): : 91 - &
  • [8] Giant Aortic Arch Aneurysm After Interrupted Aortic Arch Repair
    Alakananda Ghosh
    Amy Liu
    Bassem Mora
    Brojendra Agarwala
    [J]. Pediatric Cardiology, 2010, 31 : 1104 - 1106
  • [9] Distal Aortic Arch Aneurysm Associated with Persistent Fifth Aortic Arch
    Inoue, Takahiro
    Morita, Kiyozo
    Tanaka, Kei
    Yoshitake, Michio
    Naruse, Hitomi
    Nakao, Mitsutaka
    Hashimoto, Kazuhiro
    [J]. ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2014, 20 : 878 - 881
  • [10] Giant Aortic Arch Aneurysm After Interrupted Aortic Arch Repair
    Ghosh, Alakananda
    Liu, Amy
    Mora, Bassem
    Agarwala, Brojendra
    [J]. PEDIATRIC CARDIOLOGY, 2010, 31 (07) : 1104 - 1106