Exploring a technique for reducing the influence of scattered rays from surrounding organs to the heart during myocardial perfusion scintigraphy with technetium-99m sestamibi and technetium-99m tetrofosmin

被引:0
|
作者
Hajime Monzen
Makoto Hirata
Akira Nakanishi
Makoto Ogasawara
Takatoshi Suzuki
Rumio Yuki
Masatake Hara
Tamie Sato
Hisashi Shimoyama
Kunihiko Hirose
Futoshi Tadehara
机构
[1] Otsu Red Cross Hospital,Department of Radiology
[2] Otsu Red Cross Hospital,Department of Cardiology
[3] Kure Kyosai Hospital,Department of Internal Medicine
来源
关键词
single-photon emission tomography; technetium-99m sestamibi; technetium-99m tetrofosmin; body position; scattered rays;
D O I
暂无
中图分类号
学科分类号
摘要
We have devised a new position (Monzen position) which can suppress the influence of scattered rays from surrounding organs (liver, etc.) when conducting myocardial imaging. Unlike the conventional techniques, which require a waiting period of 30-60 minutes before imaging can be started after the infusion of technetium-99m sestamibi or technetium-99m tetrofosmin, this position allows single-photon emission tomography to be started about 5-10 minutes after the infusion of the tracer. Therefore, with this technique the total time required for imaging is reduced and consequently the physical and mental burden of the patient is also reduced. Furthermore, the number of patients who can receive this test at any facility can be increased. This position may also be applicable in myocardial scintigraphy using some other tracers.
引用
收藏
相关论文
共 50 条
  • [1] Exploring a technique for reducing the influence of scattered rays from surrounding organs to the heart during myocardial perfusion scintigraphy with technetium-99m sestamibi and technetium-99m tetrofosmin
    Monzen, Hajime
    Hara, Masatake
    Hirata, Makoto
    Nakanishi, Akira
    Ogasawara, Makoto
    Suzuki, Takatoshi
    Sato, Tamie
    Shimoyama, Hisashi
    Tadehara, Futoshi
    Hirose, Kunihiko
    Yuki, Rumio
    ANNALS OF NUCLEAR MEDICINE, 2006, 20 (10) : 705 - 710
  • [2] Differences between technetium-99m tetrofosmin and technetium-99m sestamibi in parathyroid scintigraphy
    Giordano, A
    Meduri, G
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (03) : 347 - 347
  • [3] Differences between technetium-99m tetrofosmin and technetium-99m sestamibi in parathyroid scintigraphy
    Alessandro Giordano
    Guido Meduri
    European Journal of Nuclear Medicine, 1997, 24 : 347 - 347
  • [4] Parathyroid scintigraphy: Comparison of technetium-99m methoxyisobutylisonitrile and technetium-99m tetrofosmin studies
    Aigner, RM
    Fueger, GF
    Nicoletti, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (06): : 693 - 696
  • [5] Comparative myocardial uptake of technetium-99m sestamibi and technetium-99m tetrofosmin one hour after stress injection
    Gremillet, E
    Champailler, A
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (11) : 1502 - 1510
  • [6] Technetium-99m sestamibi/tetrofosmin myocardial perfusion scanning in cardiac and noncardiac sarcoidosis
    Eguchi, M
    Tsuchihashi, K
    Hotta, D
    Hashimoto, A
    Sasao, H
    Yuda, S
    Nakata, T
    Shijubou, N
    Abe, S
    Shimamoto, K
    CARDIOLOGY, 2000, 94 (03) : 193 - 199
  • [7] Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes
    Rainer Bartosch
    Susanne Granegger
    Helmut Sinzinger
    European Journal of Nuclear Medicine, 1998, 25 : 1333 - 1335
  • [8] Adsorption of technetium-99m tetrofosmin and technetium-99m furifosmin on plastic syringes
    Bartosch, R
    Granegger, S
    Sinzinger, H
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (09) : 1333 - 1335
  • [9] Scintimammography with technetium-99m tetrofosmin
    Mansi, L
    Rambaldi, PF
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (02): : 229 - 229
  • [10] Technetium-99m tetrofosmin scintigraphy in pediatric osteogenic sarcoma
    Schillaci, O
    Spanu, A
    Scopinaro, F
    Monteleone, F
    Masala, S
    Tarantino, U
    Madeddu, G
    Simonetti, G
    ONCOLOGY REPORTS, 2003, 10 (03) : 605 - 608