X-ray residual stress measurement on mechanical components with high curvature

被引:8
|
作者
T. Berruti
M. M. Gola
机构
[1] Department of Mechanical Engineering,
[2] Politecnico di Torino,undefined
关键词
X-ray diffraction; residual stress; curvature; measurement area; loading devices;
D O I
10.1007/BF02410491
中图分类号
学科分类号
摘要
In this paper we deal with the definition of an appropriate X-ray diffraction procedure for residual stress determination on samples with high curvature radius. We choose as the application high-strength hot worked coil springs for car suspensions (wire diameterd=12 mm). Different methods of X-ray measurement area limitation are compared, taking into account the measurement errors, for the determination of stress in one and in three directions. After the identification of the irradiated area limits for plane samples, further limits are identified due to the sample curvature (torsion bar). We describe loading devices purposely designed, constructed and calibrated. In each case, the sample is loaded so that the stress state is determined at the same time both by strain gages and by X-ray measurement.
引用
收藏
页码:105 / 114
页数:9
相关论文
共 50 条
  • [1] X-ray residual stress measurement on mechanical components with high curvature
    Berruti, T
    Gola, MM
    [J]. EXPERIMENTAL MECHANICS, 2003, 43 (01) : 105 - 114
  • [2] X-RAY MEASUREMENT OF RESIDUAL STRESS IN HARDENED HIGH CARBON STEEL
    CHRISTENSON, AL
    ROWLAND, ES
    [J]. TRANSACTIONS OF THE AMERICAN SOCIETY FOR METALS, 1953, 45 : 638 - 676
  • [3] RESIDUAL STRESS MEASUREMENT OF CFRP BY X-RAY DIFFRACTION
    Doi, Taisei
    Nishida, Masayuki
    Ozaki, Junichi
    [J]. 20TH INTERNATIONAL CONFERENCE ON COMPOSITE MATERIALS, 2015,
  • [4] Volumetric Measurement of Residual Stress Using High Energy X-Ray Diffraction
    Whitesell, R.
    McKenna, A.
    Wendt, S.
    Gray, J.
    [J]. 42ND ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 6TH EUROPEAN-AMERICAN WORKSHOP ON RELIABILITY OF NDE, 2016, 1706
  • [5] Residual Stress Measurement Of High Molecular Matter By Transmission X-ray Diffraction
    Kitamura, Masashi
    Nishida, Masayuki
    Hanabusa, Takao
    [J]. RESIDUAL STRESSES VIII, 2011, 681 : 381 - +
  • [6] Application of polycapillary X-ray optics in residual stress measurement
    Guo, Fei
    Zhao, Weilin
    Wang, Xuepeng
    Lin, Xiaoyan
    Li, Yude
    [J]. INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2015, 58 (04) : 545 - 551
  • [7] X-ray measurement of residual stress in plastic bonded explosives
    Yong, ZH
    Zhu, SF
    Zhao, BJ
    Chen, JH
    Zhang, WB
    Wei, XW
    [J]. JOURNAL OF RARE EARTHS, 2006, 24 : 179 - 181
  • [8] Application of polycapillary X-ray optics in residual stress measurement
    Fei Guo
    Weilin Zhao
    Xuepeng Wang
    Xiaoyan Lin
    Yude Li
    [J]. Instruments and Experimental Techniques, 2015, 58 : 545 - 551
  • [9] LESTER HONOR LECTURE - X-RAY MEASUREMENT OF RESIDUAL STRESS
    NORTON, JT
    [J]. MATERIALS EVALUATION, 1972, 30 (09) : A30 - &
  • [10] Residual stress of aluminum thin films measured by X-ray and curvature methods
    Tanaka, K
    Ishihara, K
    Akiniwa, Y
    Ohta, H
    [J]. MATERIALS SCIENCE RESEARCH INTERNATIONAL, 1996, 2 (03): : 153 - 159