This research work studies the heat transfer characteristics of a direct contact evaporator. A cold two phase refrigerant (R12 or R22) is injected into water kept in a storage tank to exchange heat with the water directly. The water temperature is reduced to the freezing point, and ice could be formed. The lump model is used to predict the water temperature, and it is found that this model can predict the water temperature quite well. A correlation that relates the dimensionless parameters, such as Stanton number, Stephan number, Prandtl number and pressure ratio, is also developed. (C) 2002 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:497 / 508
页数:12
相关论文
共 50 条
  • [1] HEAT TRANSFER IN A FORM-STABLE DIRECT-CONTACT LATENT THERMAL ENERGY STORAGE UNIT
    Mousavi, N. S. Susan
    Syed, M. Tashfeen
    Panindre, Prabodh
    Kumar, Sunil
    JOURNAL OF ENHANCED HEAT TRANSFER, 2024, 31 (01) : 1 - 30
  • [2] Effectiveness of direct contact PCM thermal storage with a gas as the heat transfer fluid
    Belusko, M.
    Sheoran, S.
    Bruno, F.
    APPLIED ENERGY, 2015, 137 : 748 - 757
  • [3] ICE COLD ENERGY STORAGE USING DIRECT CONTACT PHASE CHANGE HEAT TRANSFER BETWEEN REFRIGERANT AND PCM IN AN ENCLOSURE.
    Utaka, Yoshio
    Saito, Aiko
    Niimi, Masaru
    Nakata, Naoki
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 1987, 53 (496): : 3757 - 3762
  • [4] Heat transfer enhancement and melting behavior of phase change material in a direct-contact thermal energy storage container
    He, Shiquan
    Wang, Weilong
    Wei, Linhao
    Ding, Jing
    JOURNAL OF ENERGY STORAGE, 2020, 31
  • [5] Evaporative cooling performance characteristics in ice thermal energy storage with direct contact discharging for food cold storage
    Ahn, Jae Hwan
    Kim, Hoon
    Kim, Jong Hoon
    Kim, Ji Young
    APPLIED ENERGY, 2023, 330
  • [6] Numerical heat transfer analysis of encapsulated ice thermal energy storage system with variable heat transfer coefficient in downstream
    Erek, Aytunc
    Dincer, Ibrahim
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (3-4) : 851 - 859
  • [7] Exergy analysis of direct-contact ice thermal storage system
    Fang, X
    Li, RY
    Yu, HL
    Chen, ZH
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR 98, 1998, : 248 - 253
  • [8] Analyses of ice slurry formation using direct contact heat transfer
    Hawlader, M. N. A.
    Wahed, M. A.
    APPLIED ENERGY, 2009, 86 (7-8) : 1170 - 1178
  • [9] Ice-slurry production using direct contact heat transfer
    Wijeysundera, NE
    Hawlader, MNA
    Andy, CWB
    Hossain, MK
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (05): : 511 - 519
  • [10] Heat transfer in ice storage and energy gains from the soil
    Goeke, Johannes
    BAUPHYSIK, 2019, 41 (02) : 96 - 103