A novel few-views arrangement of the fixed X-ray tubes for tomosynthesis

被引:0
|
作者
Hori, Kensuke [1 ]
Koike, Takahisa [1 ]
Tadano, Kiichi [1 ]
Hashimoto, Takeyuki [1 ]
机构
[1] Kyorin Univ, Grad Sch Hlth Sci, 5-4-1 Shimorenjaku, Mitaka, Tokyo 1818612, Japan
关键词
Tomosynthesis; X-ray tube arrangement; Few-views; Fixed X-ray tubes; DIGITAL TOMOSYNTHESIS; IMAGE-RECONSTRUCTION; ANGLE DATA;
D O I
10.1016/j.ejmp.2021.11.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Tomosynthesis is a technique that reconstructs a volume image from limited-angle projection data. In conventional tomosynthesis, the examination time is long, so it can be difficult for patients to hold their breath during certain examinations, such as chest imaging. Few-views tomosynthesis, which uses a linear arrangement of fixed X-ray tubes and enables an image to be obtained within 1 s, was found to be useful in the clinical setting in our previous study. In the present study, we attempted to develop a novel few-views tomosynthesis system that can obtain images with an improved image quality. Methods: A novel few-views arrangement of X-ray tubes was proposed and the image reconstruction method with regularization term was applied. The linear arrangement was used for the X-ray tube arrangement in our previous few-views tomosynthesis, in contrast, a circular arrangement was proposed in this study. The validation of this system was conducted with a numerical simulation and a real data experiment. Results: The wider the scan angle, the more the object shadow spreads from "in-plane", allowing for artifact suppression. In the circular arrangement, the constant scan angle of theta is used, but in the linear arrangement the scan angle is set from 0 to theta. The artifacts in "out-of-plane" were more strongly suppressed in the circular arrangement than in the linear arrangement. Conclusions: Artifacts spreading in the z-direction were more strongly suppressed using the circular arrangement than the linear arrangement. Therefore, the circular arrangement was deemed appropriate for few-views tomosynthesis.
引用
收藏
页码:8 / 19
页数:12
相关论文
共 50 条
  • [1] X-ray CT Image Reconstruction from Few-views via Total Generalized p-Variation Minimization
    Zhang, Hanming
    Xi, Xiaoqi
    Yan, Bin
    Han, Yu
    Li, Lei
    Chen, Jianlin
    Cai, Ailong
    [J]. 2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5618 - 5621
  • [2] CONVERSION OF A FIXED X-RAY TABLE FOR AXIAL VIEWS
    MUDD, JG
    TRICAMO, J
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1981, 7 (03): : 319 - 320
  • [3] A facility for a few views X-ray tomography of transient processes
    Miginsky, SV
    Kulipanov, GN
    Vinokurov, NA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 543 (01): : 166 - 169
  • [4] X-ray physics and x-ray tubes
    Hicks, V
    [J]. JOURNAL OF APPLIED PHYSICS, 1941, 12 (05) : 364 - 374
  • [5] X-ray tubes
    Zink, F
    [J]. RADIOLOGY, 1996, 201 : 16 - 16
  • [6] BANDPASS X-RAY DIODES AND X-RAY MULTIPLIER TUBES
    WANG, CL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (05): : 582 - 584
  • [7] Filter calculation for x-ray tomosynthesis reconstruction
    Nielsen, Tim
    Hitziger, Sebastian
    Grass, Michael
    Iske, Armin
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3915 - 3930
  • [8] OPTIMUM OPERATION OF X-RAY TUBES FOR X-RAY FLUORESCENCE
    ADLER, I
    ROSE, HJ
    [J]. SPECTROCHIMICA ACTA, 1960, 16 (05): : 628 - 628
  • [9] Reduction of X-ray Doses in Chest Tomosynthesis
    Miroshnychenko, S.
    Miroshnychenko, O.
    Nevgasymyi, A.
    Khobta, Y.
    [J]. 2018 IEEE 38TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2018, : 398 - 401
  • [10] Regularization Approach for Tomosynthesis X-Ray Inspection
    Tigkos, Konstantinos
    Hassler, Ulf
    Holub, Wolfgang
    Woerlein, Norbert
    Rehak, Markus
    [J]. 40TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 10TH INTERNATIONAL CONFERENCE ON BARKHAUSEN NOISE AND MICROMAGNETIC TESTING, VOLS 33A & 33B, 2014, 1581 : 1793 - 1799