Clinical experience of volumetric-modulated flattening filter free stereotactic body radiation therapy of lesions in the lung with deep inspiration breath-hold

被引:9
|
作者
Morkeset, Siri T. [1 ]
Lervag, Christoffer [1 ]
Lund, Jo-Asmund [1 ,2 ]
Jensen, Christer [2 ,3 ]
机构
[1] More & Romsdal Hosp Trust, Alesund Hosp, Dept Oncol & Rehabil, Alesund, Norway
[2] Norwegian Univ Sci & Technol NTNU, Fac Med & Hlth Sci, Dept Hlth Sci Alesund, Alesund, Norway
[3] More & Romsdal Hosp Trust, Alesund Hosp, Dept Med & Healthcare, Alesund, Norway
来源
关键词
deep inspiration breath-hold; DIBH; free breathing; lung; radiation therapy; radiotherapy; RT; SBRT; stereotactic body radiotherapy; CANCER RADIOTHERAPY; POSITION;
D O I
10.1002/acm2.13733
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This clinical study aimed to evaluate lung cancer patients' ability to perform deep inspiration breath-hold (DIBH) during CT simulation and throughout the treatment course of stereotactic body radiation therapy (SBRT). In addition, target sizes, organ at risk (OAR) sizes, and doses to the respective volumes in filter-free volumetric-modulated arc therapy plans performed under free-breathing (FB) and DIBH conditions were evaluated. Twenty-one patients with peripheral lesions were included, of which 13 were eligible for SBRT. All patients underwent training for breath-hold during CT, and if they complied with the requirements, two CT scans were obtained: CT scan in DIBH and a four-dimensional CT scan in FB. The treatment plans in FB and DIBH were generated, and the dose parameters and volume sizes were compared. The endpoints for evaluation were patient compliance, target dose coverage, and doses to the OARs. This clinical study showed high patient DIBH compliance during both CT simulation and treatment for patients with lung cancer. A significant reduction in target volumes was achieved with SBRT in DIBH, in addition to significantly decreased doses to the heart, chest wall, and lungs. DIBH in SBRT of lung lesions is feasible, and a routine to manage intra-fractional deviation should be established upon implementation.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Role of Volumetric-Modulated Arc Therapy with Flattening Filter Free Delivery in Lung Stereotactic Body Radiotherapy
    Liu, Hong-Wei
    Olivotto, Ivo
    Lau, Harold
    Nugent, Zoann
    Khan, Rao
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (02) : 155 - 159
  • [2] Effectiveness of robust optimization in volumetric modulated arc therapy using 6 and 10 MV flattening filter-free beam therapy planning for lung stereotactic body radiation therapy with a breath-hold technique
    Miura, Hideharu
    Ozawa, Shuichi
    Doi, Yoshiko
    Nakao, Minoru
    Kubo, Katsumaro
    Kenjo, Masahiko
    Nagata, Yasushi
    [J]. JOURNAL OF RADIATION RESEARCH, 2020, 61 (04) : 575 - 585
  • [3] Intensity modulated radiation therapy (imrt) in lung cancer : Free breathing versus voluntary deep inspiration breath-hold
    Ferreira, I.
    Voisin, N.
    Le Pechoux, C.
    Lefkopoulos, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S374 - S375
  • [4] Flattening filter-free technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy: A clinical comparison with the flattening filter technique
    Aoki, Shuri
    Yamashita, Hideomi
    Haga, Akihiro
    Nawa, Kanabu
    Imae, Toshikazu
    Takahashi, Wataru
    Abe, Osamu
    Nakagawa, Keiichi
    [J]. ONCOLOGY LETTERS, 2018, 15 (03) : 3928 - 3936
  • [5] Deep-inspiration breath-hold kilovoltage cone-beam CT for setup of stereotactic body radiation therapy for lung tumors: Initial experience
    Duggan, Dennis M.
    Ding, George X.
    Coffey, Charles W., II
    Kirby, Wyndee
    Hallahan, Dennis E.
    Malcolm, Arnold
    Lu, Bo
    [J]. LUNG CANCER, 2007, 56 (01) : 77 - 88
  • [6] Evaluation of collimator rotation for volumetric modulated arc therapy lung stereotactic body radiation therapy using flattening filter free
    Sandrini, Emmily Santos
    da Silva, Ademir Xavier
    da Silva, Claudia Menezes
    [J]. APPLIED RADIATION AND ISOTOPES, 2018, 141 : 257 - 260
  • [7] ROLE OF VOLUMETRIC MODULATED ARC THERAPY WITH FLATTENING FILTER FREE DELIVERY IN LUNG STEREOTACTIC BODY RADIOTHERAPY
    Liu, Hongwei
    Olivotto, Ivo
    Lau, Harold
    Nugent, Zoann
    Khan, Rao
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 120 : S68 - S68
  • [8] Dosimetric comparison of deep inspiration breath hold and free breathing technique in stereotactic body radiotherapy for localized lung tumor using Flattening Filter Free beam
    Mani, Karthick Raj
    Bhuiyan, Md. Anisuzzaman
    Alam, Md. Mahbub
    Ahmed, Sharif
    Sumon, Mostafa Aziz
    Sengupta, Ashim Kumar
    Rahman, Md. Shakilur
    Islam, Md. S. M. Azharul
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2018, 24 (01): : 15 - 24
  • [9] Lung Cancer: Doses to Mediastinal Structures Can Be Reduced with Volumetric Modulated Arc Therapy and Deep Inspiration Breath-Hold Radiotherapy
    Persson, Gitte F.
    Rydhog, Jonas S.
    Aznar, Marianne C.
    Maraldo, Maja V.
    Nygard, Lotte
    Costa, Junia
    Berthelsen, Anne K.
    Specht, Lena
    Josipovic, Mirjana
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2015, 10 (09) : S687 - S688
  • [10] The Feasibility of Implementing Deep Inspiration Breath-Hold for Pediatric Radiation Therapy
    Lundgaard, Anni Young
    Josipovic, Mirjana
    Rechner, Laura Ann
    Bidstrup, Pernille Envold
    Hansen, Rune
    Damkjaer, Sidsel Skov
    Joergensen, Morten
    Safwat, Akmal
    Specht, Lena
    Hjalgrim, Lisa Lyngsie
    Maraldo, Maja Vestmoe
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (05): : 977 - 984