Operating Room and Hospital Air Environment

被引:1
|
作者
Coury, John G. [1 ]
Lum, Zachary C. [1 ]
Dunn, Jacob G. [1 ]
Huff, Kathryn E. [1 ]
Lara, Daniel L. [1 ]
Trzeciak, Marc A. [1 ]
机构
[1] Doctors Med Ctr, Valley Orthoped Surg Residency, 1400 Florida Ave,Ste 200, Modesto, CA 95350 USA
关键词
D O I
10.3928/01477447-20210414-15
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
One method of preventing surgical-site infection is lowering intraoperative environmental contamination. The authors sought to evaluate their hospital's operating room (OR) contamination rate and compare it with the remainder of the hospital. They tested environmental contamination in preoperative, intraoperative, and postoperative settings for a total joint arthroplasty patient. A total of 190 air settle plates composed of trypsin soy agar were placed in 19 settings within the hospital. Locations included the OR with light and heavy traffic, with and without masks, jackets, and shoe covers; the substerile room; OR hallways; the sterile equipment processing center; preoperative areas; post-anesthesia care units; orthopedic floors; the emergency department; OR locker rooms and restrooms; a resident's home; and controls. The trypsin soy agar plates were incubated at 36 degrees C for 48 hours. Colony counts were performed for each plate. Average colony-forming units (CFUs) were calculated in each setting. The highest CFUs were in the OR locker room, at 28 CFUs per plate per hour. Preoperative and post-anesthesia care unit holding areas were 7.4 CFUs and 9.6 CFUs, respectively. The main orthopedic surgical ward had 10.0 CFUs per plate per hour, whereas the VIP hospital ward had 17.0 CFUs per plate per hour. All OR environments had low CFUs. A live OR had slightly higher CFUs than settings without OR personnel. In comparison with the local community household, the OR locker room, restrooms, hospital orthopedic wards, emergency department, preoperative holding, postanesthesia care unit, and OR hallway all had higher airborne contamination. On the basis of these results, the authors recommend environmental sampling as a simple, fast, inexpensive tool for monitoring airborne contamination.
引用
收藏
页码:E414 / E416
页数:3
相关论文
共 50 条
  • [1] Air Motion Control In the Hospital Operating Room
    Cook, Gerald
    Int-Hout, Dan
    [J]. ASHRAE JOURNAL, 2009, 51 (03) : 30 - +
  • [2] Analysis of Thermal Environment in a Hospital Operating Room
    Liu, Chunhua
    Zhou, Guang
    Li, Hongyuan
    [J]. 9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 735 - 742
  • [3] Air-conditioning design of the clean operating room in a hospital
    Wu, Y.C.
    Yin, Y.Z.
    [J]. Nuantong Kongtiao/HV & AC, 2001, 31 (05):
  • [4] GUIDELINES FOR HOSPITAL OPERATING AND DELIVERY ROOM AIR CONDITIONING SYSTEMS
    不详
    [J]. AMERICAN JOURNAL OF PUBLIC HEALTH AND THE NATIONS HEALTH, 1967, 57 (06): : 1053 - &
  • [5] Operating room environment
    Ritter, MA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1999, (369) : 103 - 109
  • [6] AIR CONDITIONER IN OPERATING ROOM
    WALTER, CW
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1956, 160 (02): : 152 - 152
  • [7] Control of the Environment in the Operating Room
    Katz, Jonathan D.
    [J]. ANESTHESIA AND ANALGESIA, 2017, 125 (04): : 1214 - 1218
  • [8] The new operating room environment
    Mansour, MA
    [J]. SURGICAL CLINICS OF NORTH AMERICA, 1999, 79 (03) : 477 - +
  • [9] AIR CONDITIONER IN OPERATING ROOM
    不详
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1955, 158 (15): : 1405 - 1405
  • [10] Comparison of CFD Simulations of Hospital Operating Room Air Distribution with Experimental PIV Results
    Stevenson, Tyler C.
    Jeter, Sheldon M.
    [J]. ASHRAE TRANSACTIONS 2013, VOL 119, PT 1, 2013, 119 : 63 - 74