Effect of incremental and submaximal constant load tests: Protocol on perceived exertion (CR10) values

被引:6
|
作者
Dekerle, J
Baron, B
Dupont, L
Garcin, M
Vanvelcenaher, J
Pelayo, P
机构
[1] Univ Lille 2, Lab Etud Motr Humaine, Fac Sci Sport & Educ Phys, F-59790 Ronchin, France
[2] Lille Hellemmes, Ctr Reeduc & Readaptat Fonct Espoir, Lille, France
关键词
D O I
10.2466/PMS.96.3.896-904
中图分类号
B84 [心理学];
学科分类号
04 ; 0402 ;
摘要
The purpose of the present investigation was to determine to what extent the protocol (incremental and constant load exercises) affects the ratings of perceived exertion for a given submaximal intensity on a cycle ergometer. 10 healthy and well-trained male students (M age=23 yr., SD=2.9) performed an incremental exercise to determine maximal oxygen uptake (VO2 Max), maximal aerobic power, and the ratings of perceived exertion (CR10) corresponding to 70% and 75% VO2 Max (CR10(70i) and CR10(75i)). Two 30-min. constant load exercises set at these intensities were performed to establish the corresponding CR10 values. CR10(70i) (5.6 +/- 1.9) and CR10(75i) (6.2 +/- 1.9) were significantly higher than all CRI10 values collected at Minutes 5, 10, 15, 20, 25, and 30 of the constant load exercises. These results indicate that, for a given exercise intensity (70% and 75% VO2 max), subjects are rated higher during an incremental exercise than during a 30-min. submaximal constant load test. Therefore, when coaches and physiotherapists want to use CR10 values reported during an incremental standard exercise to set training loads, they have to be prudent since the same relative exercise intensity does not seem to be perceived identically during a submaximal constant exercise as during an incremental one.
引用
收藏
页码:896 / 904
页数:9
相关论文
共 6 条
  • [1] Cognitive influences on perceived phonatory exertion using the Borg CR10
    van Mersbergen, Miriam
    Vinney, Lisa A.
    Payne, Alexis E.
    LOGOPEDICS PHONIATRICS VOCOLOGY, 2020, 45 (03) : 123 - 133
  • [2] Use of the CR100 Scale for Session Rating of Perceived Exertion in Soccer and Its Interchangeability With the CR10
    Fanchini, Maurizio
    Ferraresi, Ivan
    Modena, Roberto
    Schena, Federico
    Coutts, Aaron J.
    Impellizzeri, Franco M.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2016, 11 (03) : 388 - 392
  • [3] Reproducibility of heart rate and rating of perceived exertion values obtained from different incremental treadmill tests
    Peserico, C. S.
    Zagatto, A. M.
    Machado, F. A.
    SCIENCE & SPORTS, 2015, 30 (02) : 82 - 88
  • [4] Using the Borg CR10 Physical Exertion Scale to Measure Patient-perceived Vocal Effort Pre and Post Treatment
    van Leer, Eva
    van Mersbergen, Miriam
    JOURNAL OF VOICE, 2017, 31 (03) : 389.e19 - 389.e25
  • [5] Are 30 minutes of rest between two incremental shuttle walking tests enough for cardiovascular variables and perceived exertion to return to baseline values?
    Ribeiro, Las R. G.
    Mesquita, Rafael B.
    Vidotto, Lais S.
    Merli, Myriam F.
    Carvalho, Debora R.
    de Castro, Larissa A.
    Probst, Vanessa S.
    BRAZILIAN JOURNAL OF PHYSICAL THERAPY, 2015, 19 (02) : 105 - 113
  • [6] The effect of antecedent fatiguing activity on the relationship between perceived exertion and physiological activity during a constant load exercise task
    Eston, Roger
    Faulkner, James
    Gibson, Alan St Clair
    Noakes, Tim
    Parfitt, Gaynor
    PSYCHOPHYSIOLOGY, 2007, 44 (05) : 779 - 786