Distribution of ferritin and redox-active transition metals in normal and cataractous human lenses

被引:33
|
作者
Garner, B
Roberg, K
Qian, MW
Eaton, JW
Truscott, RJW
机构
[1] Univ Wollongong, Dept Chem, Australian Cataract Res Fdn, Wollongong, NSW 2522, Australia
[2] Linkoping Univ, Fac Hlth Sci, Dept Pathol 2, S-58185 Linkoping, Sweden
[3] Baylor Coll Med, Dept Pediat, Houston, TX 77030 USA
基金
英国医学研究理事会;
关键词
cataract; iron; copper; ferritin; hydroxyl-radical;
D O I
10.1006/exer.2000.0912
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Previous studies have shown that, lenticular levels of Fe and Cu are elevated in age-related cataract. However, it is not known if these metals are present in a stale that is permissive for redox reactions that may lead to the formation of free radicals. In addition, there is little data available concerning the concentration and lenticular distribution of ferritin, the major intracellular Fe-sequestering protein, in the lens. The aim of the present work was therefore to determine the distribution of ferritin and the redox-availability of Fe and Cu in healthy and cataractous lenses. Lens ferritin distribution was assessed by ELISA and immunohistochemistry. A modified ELISA detected ferritin in an 'insoluble' lens protein fraction. Ferritin levels were not significantly different in the cortex vs nucleus of healthy lenses. In contrast, ferritin levels in the cataractous lens nuclei appeared to be 70% lower compared to the cortex. This was at least partially due to the presence of ferritin within an insoluble protein fraction of the homogenized lenses. In normal lenses, ferritin staining was most intense in the epithelium, with diffuse staining observed throughout the cortex and nucleus, The redox-availability of lenticular metals was determined using: (1) autometallography; (2) Ferene-S as a chromogenic Fe chelator; and (3) NO. release from nitrosocysteine to probe for redox-active Cu. The autometallography studies showed that the cataractous lenses stained more heavily for redox-active metals in both the nucleus and cortex when compared to age-matched control lenses. Chelatable Fe was detected in homogenized control lenses after incubation with Ferene-S, with almost three-fold higher levels detected in the cataractous lenses on average. The Cu-catalysed liberation of NO. from added nitrosocysteine was not demonstrated in any lens sample. When exogenous Cu (50 nM) was added to the lenses, it was rapidly chelated. The cataractous samples were approximately twice as effective at redox-inactivation of added Cu. These studies provide evidence that a chelatable pool of potentially redox-active Fe is present at increased concentrations in human cataractous lenses. In contrast, it seems that lenticular Cu may not be readily available for participation in redox reactions, (C) 2000 Academic Press.
引用
收藏
页码:599 / 607
页数:9
相关论文
共 50 条
  • [1] Distribution of ferritin chains in noncataractous and cataractous canine lenses
    Goralska, Malgorzata
    Nagar, Steven
    Fleisher, Lloyd N.
    McGahan, M. Christine
    FASEB JOURNAL, 2009, 23
  • [2] REGIONAL DISTRIBUTION OF EXTRINSIC FLUOROPHORES IN NORMAL AND CATARACTOUS HUMAN LENSES
    YAPPERT, MC
    BYRDWELL, WC
    BORCHMAN, D
    PATERSON, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1170 - 1170
  • [3] Gold nanoparticles coated with redox-active transition metals
    Ramirez, Abril A.
    Cruz-Campa, Itzia
    Noveron, Juan C.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2007, 233 : 778 - 778
  • [4] DISTRIBUTION OF GLUTATHIONE-S-TRANSFERASE IN NORMAL AND CATARACTOUS HUMAN LENSES
    HUANG, QL
    HORWITZ, J
    LOU, MF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 800 - 800
  • [5] Polydopamine Nanoparticles Prepared Using Redox-Active Transition Metals
    Salomaki, Mikko
    Ouvinen, Tuomo
    Marttila, Lauri
    Kivela, Henri
    Leiro, Jarkko
    Makila, Ermei
    Lukkari, Jukka
    JOURNAL OF PHYSICAL CHEMISTRY B, 2019, 123 (11): : 2513 - 2524
  • [6] CALCIUM CONCENTRATION OF CATARACTOUS AND NORMAL HUMAN LENSES AND PROTEIN-FRACTIONS OF CATARACTOUS LENSES
    JEDZINIAK, JA
    NICOLI, DF
    YATES, EM
    BENEDEK, GB
    EXPERIMENTAL EYE RESEARCH, 1976, 23 (03) : 325 - 332
  • [7] SOLUBLE PROTEINS IN NORMAL AND CATARACTOUS HUMAN LENSES
    MALIK, SRK
    GUPTA, AK
    CHATTERJ.S
    AGARWAL, PS
    EXPERIMENTAL EYE RESEARCH, 1969, 8 (02) : 93 - &
  • [8] HUMAN LENS EPITHELIUM IN NORMAL AND CATARACTOUS LENSES
    FAGERHOLM, PP
    PHILIPSON, BT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1981, 21 (03) : 408 - 414
  • [9] PEROXIDE CONCENTRATION IN NORMAL AND CATARACTOUS HUMAN LENSES
    BHUYAN, DK
    CAMRAS, CB
    LAKHANI, HK
    BHUYAN, KC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 798 - 798
  • [10] Crystallins in the nucleus of normal and cataractous human lenses
    Garland, DL
    TaborDuglas, Y
    Datiles, MB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1950 - 1950