Identification and quantification of alkylketene dimers by pyrolysis-gas chromatography/mass spectrometry and pyrolysis-gas chromatography/flame ionization detection

被引:0
|
作者
Odermatt, J
Meyer, R
Meier, D
Ettl, R
机构
[1] Univ Hamburg, D-21031 Hamburg, Germany
[2] Fed Res Forestry For Prod, D-21031 Hamburg, Germany
[3] BASF AG, D-67056 Ludwigshafen, Germany
来源
JOURNAL OF PULP AND PAPER SCIENCE | 2003年 / 29卷 / 01期
关键词
ketenes; dimers; pyrolysis; gas chromatography; mass spectroscopy; flame ionization detectors;
D O I
暂无
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
The various questions and problems related to the enhanced application of synthetic sizes demand analytical methods to characterize these sizes in paper. For this purpose, pyrolysis-gas chromatography/flame ionization detection (Py-GC/FID) and pyrolysis-gas chromatogrophy/mass spectrometry (Pw-GC/MS) have been investigated Examples are the analysis of samples treated with an unknown alkylketene dimer (AKD) type and the influence of CaCO3 on the pyrolytic results. With py-GC/MS, the simultaneous quantification of AKD and other additives in paper is possible if the analysis is based on pyro lytic degradation products of AKD. When the Py-GC/FID technique is applied, the area ratios of the corresponding AKD ketone peaks can be used to determine the composition of the AKD grade, and the same correlation can be used to establish a universal calibration. This calibration enables the quantification of a broad range of AKD compositions with only one calibration.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条