Optimal Sampling and Maintenance Plans for the Lighting Retrofit Projects towards Sustainable Energy Savings

被引:4
|
作者
Ye, Xianming [1 ]
Xia, Xiaohua [1 ]
机构
[1] Univ Pretoria, Dept Elect Elect & Comp Engn, ZA-0002 Pretoria, South Africa
关键词
Lighting; Energy Efficiency; Sample size determination; Optimal control;
D O I
10.1016/j.egypro.2014.11.934
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this article, the optimal sampling and maintenance plans are both designed for the EE lighting retrofit projects. By adopting the optimal solutions, the project sponsors receive additional and sustainable energy savings over a 10 years' crediting period. The reported project performance is accurate enough to satisfy the project sampling accuracy requirements. In addition, the PDs' profit is maximised with a proper reinvestment for the lighting project maintenance. A case study of designing the optimal sampling and maintenance plans for an EE lighting retrofit project is presented for illustrative purpose. (C) 2014 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:648 / 651
页数:4
相关论文
共 43 条
  • [1] Optimal maintenance planning for sustainable energy efficiency lighting retrofit projects by a control system approach
    Ye, Xianming
    Xia, Xiaohua
    Zhang, Lijun
    Zhu, Bing
    [J]. CONTROL ENGINEERING PRACTICE, 2015, 37 : 1 - 10
  • [2] Maintenance optimization incorporating lumen degradation failure for energy-efficient lighting retrofit projects
    Ikuzwe, Alice
    Xia, Xiaohua
    Ye, Xianming
    [J]. APPLIED ENERGY, 2020, 267
  • [3] Optimal sampling plan for clean development mechanism energy efficiency lighting projects
    Ye, Xianming
    Xia, Xiaohua
    Zhang, Jiangfeng
    [J]. APPLIED ENERGY, 2013, 112 : 1006 - 1015
  • [4] Laboratory Validation of Integrated Lighting Systems Retrofit Performance and Energy Savings
    Shackelford, Jordan
    Mathew, Paul
    Regnier, Cynthia
    Walter, Travis
    [J]. ENERGIES, 2020, 13 (13)
  • [5] Energy optimisations in large-scale lighting retrofit projects
    Ye, Xianming
    Xia, Xiaohua
    [J]. PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 9208 - 9213
  • [6] Performance risks of lighting retrofit in Energy Performance Contracting projects
    Lee, P.
    Lam, P. T., I
    Lee, W. L.
    [J]. ENERGY FOR SUSTAINABLE DEVELOPMENT, 2018, 45 : 219 - 229
  • [7] Improvements to longitudinal Clean Development Mechanism sampling designs for lighting retrofit projects
    Carstens, Herman
    Xia, Xiaohua
    Ye, Xianming
    [J]. APPLIED ENERGY, 2014, 126 : 256 - 265
  • [8] Corridor lighting retrofit based on occupancy and daylight sensors: implementation and energy savings compared to LED lighting
    Akrasakis, Stavros
    Tsikalakis, Antonios G.
    [J]. ADVANCES IN BUILDING ENERGY RESEARCH, 2018, 12 (02) : 274 - 288
  • [9] Efficient longitudinal population survival survey sampling for the measurement and verification of lighting retrofit projects
    Carstens, Herman
    Xia, Xiaohua
    Yadavalli, Sarma
    Rajan, Arvind
    [J]. ENERGY AND BUILDINGS, 2017, 150 : 163 - 176
  • [10] Proposed Design Process for Deep Energy Savings in Commercial Building Retrofit Projects
    Parrish, Kristen
    Regnier, Cindy
    [J]. JOURNAL OF ARCHITECTURAL ENGINEERING, 2013, 19 (02) : 71 - 80