Subtraction helical CT angiography of intra- and extracranial vessels: Technical considerations and preliminary experience

被引:0
|
作者
Jayakrishnan, VK
White, PM
Aitken, D
Crane, P
McMahon, AD
Teasdale, EM
机构
[1] Inst Neurol Sci, Dept Neuroradiol, Glasgow, Lanark, Scotland
[2] Western Gen Hosp, Dept Neuroradiol, Edinburgh EH4 2XU, Midlothian, Scotland
[3] Philips Med Syst, Glasgow, Lanark, Scotland
[4] Robertson Ctr Biostat, Glasgow, Lanark, Scotland
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Reported CT angiographic (CTA) subtraction methods are not simple, robust, or real time. We investigated a novel technique for semiautomated digital subtraction CTA of the intracranial and extracranial arteries. METHODS: Thirty patients underwent precontrast (low milliampere-seconds) and postcontrast (pitch, 1.5; collimation, 1-2.5 mm) helical imaging with a vacuum-type head holder to facilitate image registration and minimize movement. A reconstructed three-dimensional model of the precontrast bone dataset was subtracted from the postcontrast dataset to produce subtracted maximum-intensity-projection angiograms. Experienced (operator 1) and less-experienced (operator 2) staff performed the standard and subtraction reconstructions, and image generation time and quality (graded 1-5) were compared. A third operator blinded to the method assessed the hard-copy image quality. RESULTS: Image. quality with subtraction postprocessing was significantly better with both operators (operator 1, mean improvement of 0.87 grade, median improvement of 1 grade, P <.001; operator 2, mean improvement of 0.63 grade, median improvement of 1 grade, P <.001). Hard-copy image quality was better with the subtraction method (operator 1, P >.001; operator 2, P <.001). Blood vessels at the base of the brain were better demonstrated on subtraction images in 13 of 14 examinations. For the less experienced operator, the reconstruction time was significantly less with the subtraction method than with the conventional method (mean, 7.5 vs 10.1 minutes; P =.001). CONCLUSION: When separation of the vasculature from bone is important and technically difficult, digital subtraction CTA offers a potential advantage. This semiautomated technique is fast and easy to learn, and variably experienced staff can use it.
引用
收藏
页码:451 / 455
页数:5
相关论文
共 50 条
  • [1] Subtraction helical CT angiography of intra- and extracranial vessels: technical considerations and preliminary experience - Rediscovery of matched mask bone elimination?
    Venema, HW
    den Heeten, GJ
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2003, 24 (07) : 1491 - 1491
  • [2] SPIRAL CT ANGIOGRAPHY WITH DIGITAL SUBTRACTION OF EXTRACRANIAL AND INTRACRANIAL VESSELS
    GORZER, H
    HEIMBERGER, K
    SCHINDLER, E
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (05) : 839 - 841
  • [3] Comparison of dual-source CT angiography and MR angiography in preoperative evaluation of intra- and extracranial vessels: a pilot study
    Georg Mühlenbruch
    Marco Das
    Gottfried Mommertz
    Meike Schaaf
    Stefan Langer
    Andreas Horst Mahnken
    Joachim Ernst Wildberger
    A. Thron
    Rolf W. Günther
    Timo Krings
    [J]. European Radiology, 2010, 20 : 469 - 476
  • [4] Comparison of dual-source CT angiography and MR angiography in preoperative evaluation of intra- and extracranial vessels: a pilot study
    Muehlenbruch, Georg
    Das, Marco
    Mommertz, Gottfried
    Schaaf, Meike
    Langer, Stefan
    Mahnken, Andreas Horst
    Wildberger, Joachim Ernst
    Thron, A.
    Guenther, Rolf W.
    Krings, Timo
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (02) : 469 - 476
  • [5] DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) OF THE EXTRACRANIAL CEREBRAL VESSELS
    PORTE, ME
    MCIVOR, J
    [J]. CLINICAL RADIOLOGY, 1992, 46 (03) : 218 - 218
  • [6] ANGIOGRAPHY OF A RARE INTRA- AND EXTRACRANIAL CIRCULATORY ANASTOMOSIS
    BONIS, G
    KOSMAOGLOU, V
    HARDER, J
    [J]. FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1969, 110 (01): : 124 - +
  • [7] Letter to the Editor regarding: Comparison of dual-source CT angiography and MR angiography in preoperative evaluation of intra- and extracranial vessels: a pilot study
    Montorsi, Piero
    Ballerini, Giovanni
    Annoni, Andrea
    Formenti, Alberto
    Andreini, Daniele
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (09) : 2200 - 2201
  • [8] Letter to the Editor regarding: Comparison of dual-source CT angiography and MR angiography in preoperative evaluation of intra- and extracranial vessels: a pilot study
    Piero Montorsi
    Giovanni Ballerini
    Andrea Annoni
    Alberto Formenti
    Daniele Andreini
    [J]. European Radiology, 2010, 20 : 2200 - 2201
  • [9] Emergent Computed Tomography Angiography of Intra- and Extracranial Vessels; Ordering Patterns and Yield at a Single Institution
    Hextrum, Shannon
    Ortiz, Jorge
    Hornik, Jonatan
    Rosenblum, Jordan
    Bar, Barak
    [J]. ANNALS OF NEUROLOGY, 2017, 82 : S99 - S100
  • [10] Virtual realty based visualization of intra- and extracranial vessels
    Fellner, FA
    Fellner, C
    Wutke, R
    Trenkler, J
    Fiedler, E
    Matzel, K
    Bautz, WA
    [J]. NEW ASPECTS OF HIGH TECHNOLOGY IN MEDICINE, 2000, : 327 - 330