Evaluation of coronary atheroma by 64-slice multidetector computed tomography: Comparison with intravascular ultrasound and angiography

被引:17
|
作者
Ugolini, Patricia [2 ]
Pressacco, Josephine [2 ]
Lesperance, Jacques [2 ]
Berry, Colin [3 ]
L'Allier, Philippe L. [3 ]
Ibrahim, Reda [3 ]
Gregoire, Jean [3 ]
Ouellet, Robert [4 ]
Heinonen, Therese [1 ]
Levesque, Sylvie [1 ]
Guertin, Marie-Claude [1 ]
Tardif, Jean-Claude [1 ,3 ]
机构
[1] Univ Montreal, Montreal Heart Inst, Coordinating Ctr, Montreal, PQ H1T 1C8, Canada
[2] Univ Montreal, Dept Radiol, Montreal, PQ H1T 1C8, Canada
[3] Univ Montreal, Dept Med, Montreal, PQ H1T 1C8, Canada
[4] Univ Montreal, Dept Bioengn, Montreal, PQ H1T 1C8, Canada
关键词
Angiography; Atherosclerosis; Coronary disease; Tomography; Ultrasonics; ATHEROSCLEROTIC PLAQUE; LESIONS; AVASIMIBE; ACCURACY;
D O I
10.1016/S0828-282X(09)70161-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Recent improvements in multidetector computed tomography (MDCT) with 64-slice scanners have allowed acquisition of a coronary study in 5 s to 6 s, with good temporal and spatial resolution. Previous studies have reported an underestimation of plaque burden by MDCT Whether shorter scan times can allow correct assessment of plaque Volume requires comparison with intravascular ultrasound (IVUS). METHODS: Patients (n=30) scheduled for coronary angiography also underwent MDCT and IVUS examinations within 96 h. MDCT examination was performed with a 64-slice scanner. Nitroglycerin was administered before all imaging procedures. MDCT, quantitative coronary angiography (QCA) and IVUS analyses were performed by observers blinded to other results. Plaque volumes were determined by MDCT and IVUS it) one vessel, and maximum percentage diameter stenosis was identified in each coronary segment by MDCT and QCA. RESULTS: The mean (+/- SD) plaque volume was determined to be 179.1 +/- 78.9 mm(3) by MDCT and 176.1 +/- 87.9 mm(3) by IVUS. There was a strong positive correlation for plaque volume between MDCT and IVUS (r=0.84, P<0.0001). Percentage diameter stenosis assessed by MDCT and QCA also correlated well (r=0.88 per patient and r=0.87 per vessel, P<0.0001 for both). The maximum percentage diameter stenosis per vessel was 38.1 +/- 30.2% with MDCT and 34.1 +/- 27.6% with QCA. The sensitivity and specificity of MDCT it) detecting stenoses above 50% per vessel were 100% and 91.0%, respectively. CONCLUSIONS: Plaque volumes measured by 64-slice MDCT and IVUS correlate well, without systematic underestimation. The sensitivity and specificity of MDCT to detect stenoses greater than 50% by QCA are excellent with the administration of nitroglycerin before imaging.
引用
收藏
页码:641 / 647
页数:7
相关论文
共 50 条
  • [1] Assessment of Nonculprit Vulnerable Plaque by 64-Slice Multidetector Computed Tomography in Comparison to Intravascular Ultrasound
    Makino, Kunihiko
    Takagi, Takuro
    Kusunose, Yukiko
    Lee, Tetsuo
    Nakamura, Masato
    Sugi, Kaoru
    CIRCULATION, 2012, 126 (21)
  • [2] Accuracy of 64-slice computed tomography for the definition of the atherosclerotic coronary plaque: Comparison with coronary artery angiography and intravascular ultrasound
    D'Angeli, Ilaria
    Pedrazzini, Giovanni
    Faletra, Francesco
    Pasotti, Elena
    Gaudio, Carlo
    Moccetti, Tiziano
    De Castro, Stefano
    Auricchio, Angelo
    Ticino, Cardiocentro
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : A227 - A227
  • [3] Accuracy of 64-slice multidetector computed tomography for classification and quantitation of coronary plaque: Comparison with integrated backscatter intravascular ultrasound
    Harada, Ken
    Amano, Tetsuya
    Uetani, Tadayuki
    Funahashi, Hidehito
    Arai, Kosuke
    Okada, Koji
    Hirashiki, Akihiro
    Hayashi, Mutsuharu
    Oshima, Satoru
    Ishii, Hideki
    Izawa, Hideo
    Matsubara, Tatsuaki
    Murohara, Toyoaki
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 149 (01) : 95 - 101
  • [4] THE POTENTIAL OF 64-SLICE MULTIDETECTOR COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY TO REPLACE INVASIVE CORONARY ANGIOGRAPHY - THE ONTARIO MULTIDETECTOR COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY STUDY (OMCAS)
    Freeman, Michael Richard
    Chow, Ben
    Bowen, James
    Goeree, Ron
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [5] Quantification of coronary lesions by 64-slice computed tomography compared with quantitative coronary angiography and intravascular ultrasound - Reply
    Achenbach, S
    Daniel, WG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 891 - 892
  • [6] Comparison of calcified and noncalcified coronary atherosclerotic plaque volume by 64-slice multidetector computed tomography versus intravascular ultrasound.
    Kil, U. H.
    Kim, P. J.
    Chang, K. Y.
    Park, H. J.
    Park, C. S.
    Jung, H. O.
    Baek, S. H.
    Seung, K. B.
    Choi, K. B.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08): : 32F - 32F
  • [7] EVALUATION OF MYOCARDIAL BRIDGE WITH 64-SLICE COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY
    Bayrak, F.
    Guneysu, T.
    Sevinc, D.
    Eroglu, E.
    Gemici, G.
    Mutlu, B.
    Aytaclar, S.
    Degertekin, M.
    ATHEROSCLEROSIS SUPPLEMENTS, 2008, 9 (01) : 165 - 165
  • [8] Evaluation of myocardial bridges with 64-slice computed tomography coronary angiography
    Bayrak, Fatih
    Degertekin, Muzaffer
    Eroglu, Elif
    Guneysu, Tahsin
    Sevinc, Deniz
    Gemici, Gokmen
    Mutlu, Bulent
    Aytaclar, Semih
    ACTA CARDIOLOGICA, 2009, 64 (03) : 341 - 346
  • [9] Non-invasive assessment of plaque rupture by 64-slice multidetector computed tomography - Comparison with intravascular ultrasound
    Tanaka, Atsushi
    Shimada, Kenei
    Yoshida, Ken
    Jissyo, Satoshi
    Tanaka, Hidemasa
    Sakamoto, Makoto
    Matsuba, Kunio
    Imanishi, Toshio
    Akasaka, Takashi
    Yoshikawa, Junichi
    CIRCULATION JOURNAL, 2008, 72 (08) : 1276 - 1281
  • [10] Non-invasive assessment of plaque rupture by 64-slice multidetector computed tomography:comparison with intravascular ultrasound
    Tanaka, A.
    Kenei, S.
    Yoshida, K.
    Tanaka, H.
    Sakamoto, M.
    Matsuba, K.
    Kashiwaghi, M.
    Akasaka, T.
    Yoshikawa, J.
    EUROPEAN HEART JOURNAL, 2008, 29 : 282 - 282