Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography

被引:515
|
作者
Medeiros, FA
Zangwill, LM
Bowd, C
Vessani, RM
Susanna, R
Weinreb, RN
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, La Jolla, CA 92093 USA
[2] Univ Calif San Diego, Dept Ophthalmol, La Jolla, CA 92093 USA
[3] Univ Sao Paulo, Dept Ophthalmol, BR-05508 Sao Paulo, Brazil
关键词
D O I
10.1016/j.ajo.2004.08.069
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To compare the ability of optical coherence tomography retinal nerve fiber layer (RNFL), optic nerve head, and macular thickness parameters to differentiate between healthy eyes and eyes with glaucomatous visual field loss. DESIGN: Observational case-control study. METHODS: Eighty,eight patients with glaucoma and 78 healthy subjects were included. All patients underwent ONH, RNFL thickness, and macular thickness scans with Stratus OCT during the same visit. ROC curves and sensitivities at fixed specificities were calculated for each parameter. A discriminant analysis was performed to develop a linear discriminant function designed to identify and combine the best parameters. This LDF was subsequently tested on an independent sample consisting of 63 eyes of 63 subjects (27 glaucomatous and 36 healthy individuals) from a different geographic area. RESULTS: No statistically significant difference was found between the areas under the ROC curves (AUC) for the RNFL thickness parameter with the largest AUC (inferior thickness, AUC = 0.91) and the ONH parameter with largest AUC (cup/disk area ratio, AUC = 0.88) W = .28). The RNFL parameter inferior thickness had a significantly larger AUC than the macular thickness parameter with largest AUC (inferior outer macular thickness, AUC = 0.81) W = .004). A combination of selected RNFL and ONH parameters resulted in the best classification function for glaucoma detection with an AUC of 0.97 when applied to the independent sample. CONCLUSIONS: RNFL and ONH measurements had the best discriminating performance among the several Stratus OCT parameters. A combination of ONH and RNFL parameters improved the diagnostic accuracy for glaucoma detection using this instrument. (C) 2005 by Elsevier Inc. All rights reserved.
引用
收藏
页码:44 / 55
页数:12
相关论文
共 50 条
  • [1] Measurement of Retinal Nerve Fiber Layer Thickness and Macular Volume for Glaucoma Detection Using Optical Coherence Tomography
    Tomonari Ojima
    Teruyo Tanabe
    Masanori Hangai
    Saiyuu Yu
    Shiho Morishita
    Nagahisa Yoshimura
    [J]. Japanese Journal of Ophthalmology, 2007, 51 : 197 - 203
  • [2] Measurement of retinal nerve fiber layer thickness and macular volume for glaucoma detection using optical coherence tomography
    Ojima, Tomonari
    Tanabe, Teruyo
    Hangai, Masanori
    Yu, Saiyuu
    Morishita, Shiho
    Yoshimura, Nagahisa
    [J]. JAPANESE JOURNAL OF OPHTHALMOLOGY, 2007, 51 (03) : 197 - 203
  • [3] Detection of Glaucoma Progression with Stratus OCT Retinal Nerve Fiber Layer, Optic Nerve Head, and Macular Thickness Measurements
    Medeiros, Felipe A.
    Zangwill, Linda M.
    Alencar, Luciana M.
    Bowd, Christopher
    Sample, Pamela A.
    Susanna, Remo, Jr.
    Weinreb, Robert N.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (12) : 5741 - 5748
  • [4] Evaluation of the reproducibility of retinal nerve fiber layer thickness and optic nerve head parameters with optical coherence tomography
    Rau, Ricardo
    de Freitas Silva, Andre Luiz
    Alves Salame, Andre Luiz
    Soares Melo Junior, Luiz Alberto
    [J]. REVISTA BRASILEIRA DE OFTALMOLOGIA, 2012, 71 (05) : 280 - 284
  • [5] Optic nerve head, retinal nerve fiber layer, and macular thickness characteristics on optical coherence tomography in optic disk hypoplasia.
    Srinivasan, Geetha
    Venkatesh, Pradeep
    Garg, Satpal
    [J]. JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2007, 44 (03) : 140 - 141
  • [6] Evaluation of Macular Thickness and Peripapillary Retinal Nerve Fiber Layer Thickness for Detection of Early Glaucoma Using Spectral Domain Optical Coherence Tomography
    Nakatani, Yusuke
    Higashide, Tomomi
    Ohkubo, Shinji
    Takeda, Hisashi
    Sugiyama, Kazuhisa
    [J]. JOURNAL OF GLAUCOMA, 2011, 20 (04) : 252 - 259
  • [7] Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma
    Wollstein, G
    Schuman, JS
    Price, LL
    Aydin, A
    Stark, PC
    Hertzmark, E
    Lai, E
    Ishikawa, H
    Mattox, C
    Fujimoto, JG
    Paunescu, LA
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2005, 123 (04) : 464 - 470
  • [8] Evaluation of optic nerve head and retinal nerve fiber layer in early and advance glaucoma using frequency-domain optical coherence tomography
    Songfeng Li
    Xiaozhen Wang
    Shuning Li
    Gewei Wu
    Ningli Wang
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2010, 248 : 429 - 434
  • [9] Evaluation of optic nerve head and retinal nerve fiber layer in early and advance glaucoma using frequency-domain optical coherence tomography
    Li, Songfeng
    Wang, Xiaozhen
    Li, Shuning
    Wu, Gewei
    Wang, Ningli
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (03) : 429 - 434
  • [10] Positional Independence of Optic Nerve Head and Retinal Nerve Fiber Layer Thickness Measurements With Spectral-Domain Optical Coherence Tomography
    Mansouri, Kaweh
    Liu, John H. K.
    Tafreshi, Ali
    Medeiros, Felipe A.
    Weinreb, Robert N.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (04) : 712 - 721