Corneal Stiffness and Its Relationship With Other Corneal Biomechanical and Nonbiomechanical Parameters in Myopic Eyes of Chinese Patients

被引:31
|
作者
Zhang, Yaohua [1 ]
Wang, Yan [1 ,2 ]
Li, Liuyang [1 ]
Dou, Rui [2 ]
Wu, Wenjing [2 ]
Wu, Di [2 ]
Jhanji, Vishal [3 ,4 ]
机构
[1] Tianjin Med Univ, Clin Coll Ophthalmol, Tianjin, Peoples R China
[2] Tianjin Eye Hosp & Eye Inst, Tianjin Key Lab Ophthalmol & Visual Sci, Tianjin, Peoples R China
[3] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Sha Tin, Hong Kong, Peoples R China
[4] Univ Pittsburgh, UPMC Eye Ctr, Pittsburgh, PA USA
基金
中国国家自然科学基金;
关键词
corneal stiffness; myopia; corneal biomechanics; OCULAR RESPONSE ANALYZER; INTRAOCULAR-PRESSURE; AIR-PUFF; THICKNESS; DEFORMATION; AGE; KERATOCONUS; RIBOFLAVIN; GLAUCOMA; HEALTHY;
D O I
10.1097/ICO.0000000000001605
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate corneal stiffness and analyze its possible influence on other corneal biomechanical and nonbiomechanical parameters in myopic eyes of Chinese patients. Methods: A total of 387 healthy (right) myopic eyes were included in this study. Corneal visualization Scheimpflug technology was used to measure the corneal stiffness parameter at the first applanation (SP-A1), deformation amplitude ratio at 1.0 and at 2.0 mm, biomechanically corrected intraocular pressure (bIOP), and corneal deformation parameters during the first applanation (A1: A1-time, A1-length, and A1-velocity), second applanation (A2; A2-time, A2-length, and A2-velocity), and highest concavity (HC; HC-time, HC-radius, HC deformation amplitude, and HC peak distance). The Pentacam was used to evaluate central corneal thickness, mean corneal curvature (Km), anterior corneal central elevation, and corneal asphericity (Q value) of the anterior cornea. Results: The mean SP-A1 and bIOP values were 90.46 +/- 15.39 mm Hg/mm and 13.5 +/- 1.85 mm Hg, respectively. The SP-A1 increased with age (beta = 0.41 [95% CI, 0.28%-0.54%]; P < 0.0001). Corneal stiffness was positively correlated with central corneal thickness, uncorrected intraocular pressure, and bIOP and was also significantly correlated with all corneal deformation parameters (P < 0.05), except A1-length, HC-time, and HC peak distance. Corneal stiffness was negatively correlated with central corneal elevation of the anterior surface (r = -0.124, P = 0.014) and mean corneal curvature (r = -0.114, P = 0.025) and positively correlated with the Q value of the anterior surface (r = 0.109, P = 0.032). Conclusions: Corneal stiffness increased with age. Stronger corneal stiffness may be related to flattening of the cornea and higher intraocular pressure.
引用
收藏
页码:881 / 885
页数:5
相关论文
共 50 条
  • [1] Central corneal thickness and its relationship to ocular parameters in young adult myopic eyes
    Wang, Qing
    Liu, Wenwen
    Wu, Yili
    Ma, Yan
    Zhao, Guiqiu
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2017, 100 (03) : 250 - 254
  • [2] The Effect of Contact Lens Usage on Corneal Biomechanical Parameters in Myopic Patients
    Cankaya, Ali B.
    Beyazyildiz, Emrullah
    Ileri, Dilek
    Ozturk, Faruk
    [J]. CORNEA, 2012, 31 (07) : 764 - 769
  • [3] Comparison of Corneal Biomechanical Properties among Axial Myopic, Nonaxial Myopic, and Nonmyopic Eyes
    Tubtimthong, Aratchaporn
    Chansangpetch, Sunee
    Ratprasatporn, Nitee
    Manassakorn, Anita
    Tantisevi, Visanee
    Rojanapongpun, Prin
    Lin, Shan C.
    [J]. BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [4] Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes
    Hua, Yanjun
    Pan, Chao
    Wang, Qinmei
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (11) : 2467 - 2475
  • [5] Assessment of total corneal power after myopic corneal refractive surgery in Chinese eyes
    Yanjun Hua
    Chao Pan
    Qinmei Wang
    [J]. International Ophthalmology, 2019, 39 : 2467 - 2475
  • [6] Analysis of the correlation between biomechanical properties and corneal densitometry in myopic eyes
    Zheng, Yuwei
    Xue, Chao
    Wang, Jing
    Chen, Xuan
    Wang, Xiaohui
    Wang, Yan
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [7] Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging
    A-Yong Yu
    Hui Shao
    Anpeng Pan
    Qinmei Wang
    Zixu Huang
    Benhao Song
    Colm McAlinden
    Jinhai Huang
    Sisi Chen
    [J]. BMC Ophthalmology, 20
  • [8] Corneal biomechanical properties in myopic eyes evaluated via Scheimpflug imaging
    Yu, A-Yong
    Shao, Hui
    Pan, Anpeng
    Wang, Qinmei
    Huang, Zixu
    Song, Benhao
    McAlinden, Colm
    Huang, Jinhai
    Chen, Sisi
    [J]. BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [9] Corneal Biomechanical Properties in Myopic Eyes Measured by a Dynamic Scheimpflug Analyzer
    Wang, Jingyi
    Li, Ying
    Jin, Yumei
    Yang, Xue
    Zhao, Chan
    Long, Qin
    [J]. JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [10] Influence of intrastromal corneal ring segment implantation on corneal biomechanical parameters in keratoconic eyes
    Ebru Gorgun
    Raciha Beril Kucumen
    Nursal Melda Yenerel
    [J]. Japanese Journal of Ophthalmology, 2011, 55 : 467 - 471